This attribute indicates the most recent cell transfer delay value
calculated for this connection. Cell transfer delay is calculated as
half of the measured segment round trip delay of a loopback cell.
The value is noMeasurement when the ctdCalculation attribute of
the AtmIf component is off.
The value is noMeasurement when the segSwitchSideLoopback
attribute value is off for the connection.
The value is noMeasurement when the switch-side loopback is not
working.
The value is noMeasurement when the switch-side loopback status
cannot be determined.
VALUES (
0 = noMeasurement
)
Parsed from file nortelPC-atmCoreV1.mib.txt
Company: None
Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB
This attribute indicates the most recent cell transfer delay value
calculated for this connection. Cell transfer delay is calculated as
half of the measured segment round trip delay of a loopback cell.
The value is noMeasurement when the ctdCalculation attribute of
the AtmIf component is off.
The value is noMeasurement when the segSwitchSideLoopback
attribute value is off for the connection.
The value is noMeasurement when the switch-side loopback is not
working.
The value is noMeasurement when the switch-side loopback status
cannot be determined.
VALUES (
0 = noMeasurement
)
Parsed from file Nortel-MsCarrier-MscPassport-AtmCoreMIB.mib
Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB
Vendor: Northern Telecom, Ltd.
Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB
[Automatically extracted from oidview.com]
mscAtmIfVccCurrentCtd OBJECT-TYPE SYNTAX Unsigned32 (0 | 1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the most recent cell transfer delay value calculated for this connection. Cell transfer delay is calculated as half of the measured segment round trip delay of a loopback cell. The value is noMeasurement when the ctdCalculation attribute of the AtmIf component is off. The value is noMeasurement when the segSwitchSideLoopback attribute value is off for the connection. The value is noMeasurement when the switch-side loopback is not working. The value is noMeasurement when the switch-side loopback status cannot be determined. VALUES ( 0 = noMeasurement )" ::= { mscAtmIfVccPerfEntry 40 }
mscAtmIfVccCurrentCtd OBJECT-TYPE SYNTAX Unsigned32 (0 | 1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the most recent cell transfer delay value calculated for this connection. Cell transfer delay is calculated as half of the measured segment round trip delay of a loopback cell. The value is noMeasurement when the ctdCalculation attribute of the AtmIf component is off. The value is noMeasurement when the segSwitchSideLoopback attribute value is off for the connection. The value is noMeasurement when the switch-side loopback is not working. The value is noMeasurement when the switch-side loopback status cannot be determined. VALUES ( 0 = noMeasurement )" ::= { mscAtmIfVccPerfEntry 40 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.562.36.2.1.114.5.150.1.10 | mscAtmIfVccLastMinimumCtd | 0 | 0 | This attribute indicates the minimum calculated cell transfer delay value for this connection from the previous TODA (time of da… |
1.3.6.1.4.1.562.36.2.1.114.5.150.1.20 | mscAtmIfVccLastMaximumCtd | 0 | 0 | This attribute indicates the maximum calculated cell transfer delay value for this connection from the previous TODA (time of da… |
1.3.6.1.4.1.562.36.2.1.114.5.150.1.30 | mscAtmIfVccLastAverageCtd | 0 | 0 | This attribute indicates the average of all calculated cell transfer delay values for this connection from the previous TODA (ti… |
1.3.6.1.4.1.562.36.2.1.114.5.150.1.50 | mscAtmIfVccLastCtdSampleSize | 0 | 0 | This attribute indicates the number of loopback cells sampled for cell transfer delay calculations during the previous TODA (tim… |