Reference record for OID 1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.14




parent
1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1 (mscAtmIfVptVccTmAbrOperEntry)
node code
14
node name
mscAtmIfVptVccTmAbrRateIncreaseFactor
dot oid
1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.14
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAtmIf(114) mscAtmIfVpt(9) mscAtmIfVptVcc(20) mscAtmIfVptVccTm(7) mscAtmIfVptVccTmAbr(2) mscAtmIfVptVccTmAbrOperTable(110) mscAtmIfVptVccTmAbrOperEntry(1) mscAtmIfVptVccTmAbrRateIncreaseFactor(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAtmIf(114) mscAtmIfVpt(9) mscAtmIfVptVcc(20) mscAtmIfVptVccTm(7) mscAtmIfVptVccTmAbr(2) mscAtmIfVptVccTmAbrOperTable(110) mscAtmIfVptVccTmAbrOperEntry(1) mscAtmIfVptVccTmAbrRateIncreaseFactor(14)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAtmIf(114) mscAtmIfVpt(9) mscAtmIfVptVcc(20) mscAtmIfVptVccTm(7) mscAtmIfVptVccTmAbr(2) mscAtmIfVptVccTmAbrOperTable(110) mscAtmIfVptVccTmAbrOperEntry(1) mscAtmIfVptVccTmAbrRateIncreaseFactor(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAtmIf(114) mscAtmIfVpt(9) mscAtmIfVptVcc(20) mscAtmIfVptVccTm(7) mscAtmIfVptVccTmAbr(2) mscAtmIfVptVccTmAbrOperTable(110) mscAtmIfVptVccTmAbrOperEntry(1) mscAtmIfVptVccTmAbrRateIncreaseFactor(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAtmIf(114) mscAtmIfVpt(9) mscAtmIfVptVcc(20) mscAtmIfVptVccTm(7) mscAtmIfVptVccTmAbr(2) mscAtmIfVptVccTmAbrOperTable(110) mscAtmIfVptVccTmAbrOperEntry(1) mscAtmIfVptVccTmAbrRateIncreaseFactor(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAtmIf(114) mscAtmIfVpt(9) mscAtmIfVptVcc(20) mscAtmIfVptVccTm(7) mscAtmIfVptVccTmAbr(2) mscAtmIfVptVccTmAbrOperTable(110) mscAtmIfVptVccTmAbrOperEntry(1) mscAtmIfVptVccTmAbrRateIncreaseFactor(14)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAtmIf(114) mscAtmIfVpt(9) mscAtmIfVptVcc(20) mscAtmIfVptVccTm(7) mscAtmIfVptVccTmAbr(2) mscAtmIfVptVccTmAbrOperTable(110) mscAtmIfVptVccTmAbrOperEntry(1) mscAtmIfVptVccTmAbrRateIncreaseFactor(14)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAtmIf(114) mscAtmIfVpt(9) mscAtmIfVptVcc(20) mscAtmIfVptVccTm(7) mscAtmIfVptVccTmAbr(2) mscAtmIfVptVccTmAbrOperTable(110) mscAtmIfVptVccTmAbrOperEntry(1) mscAtmIfVptVccTmAbrRateIncreaseFactor(14)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/nortel/msCarrier/mscPassport/mscComponents/mscAtmIf/mscAtmIfVpt/mscAtmIfVptVcc/mscAtmIfVptVccTm/mscAtmIfVptVccTmAbr/mscAtmIfVptVccTmAbrOperTable/mscAtmIfVptVccTmAbrOperEntry/mscAtmIfVptVccTmAbrRateIncreaseFactor
  • /iso/identified-organization/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscAtmIf/mscAtmIfVpt/mscAtmIfVptVcc/mscAtmIfVptVccTm/mscAtmIfVptVccTmAbr/mscAtmIfVptVccTmAbrOperTable/mscAtmIfVptVccTmAbrOperEntry/mscAtmIfVptVccTmAbrRateIncreaseFactor
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscAtmIf/mscAtmIfVpt/mscAtmIfVptVcc/mscAtmIfVptVccTm/mscAtmIfVptVccTmAbr/mscAtmIfVptVccTmAbrOperTable/mscAtmIfVptVccTmAbrOperEntry/mscAtmIfVptVccTmAbrRateIncreaseFactor
  • /iso/org/dod/internet/private/enterprise/nt/msCarrier/mscPassport/mscComponents/mscAtmIf/mscAtmIfVpt/mscAtmIfVptVcc/mscAtmIfVptVccTm/mscAtmIfVptVccTmAbr/mscAtmIfVptVccTmAbrOperTable/mscAtmIfVptVccTmAbrOperEntry/mscAtmIfVptVccTmAbrRateIncreaseFactor
  • /iso/org/dod/internet/private/enterprises/nortel/msCarrier/mscPassport/mscComponents/mscAtmIf/mscAtmIfVpt/mscAtmIfVptVcc/mscAtmIfVptVccTm/mscAtmIfVptVccTmAbr/mscAtmIfVptVccTmAbrOperTable/mscAtmIfVptVccTmAbrOperEntry/mscAtmIfVptVccTmAbrRateIncreaseFactor
  • /iso/org/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscAtmIf/mscAtmIfVpt/mscAtmIfVptVcc/mscAtmIfVptVccTm/mscAtmIfVptVccTmAbr/mscAtmIfVptVccTmAbrOperTable/mscAtmIfVptVccTmAbrOperEntry/mscAtmIfVptVccTmAbrRateIncreaseFactor
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscAtmIf/mscAtmIfVpt/mscAtmIfVptVcc/mscAtmIfVptVccTm/mscAtmIfVptVccTmAbr/mscAtmIfVptVccTmAbrOperTable/mscAtmIfVptVccTmAbrOperEntry/mscAtmIfVptVccTmAbrRateIncreaseFactor
  • /iso/iso-identified-organization/dod/internet/private/enterprises/nt/msCarrier/mscPassport/mscComponents/mscAtmIf/mscAtmIfVpt/mscAtmIfVptVcc/mscAtmIfVptVccTm/mscAtmIfVptVccTmAbr/mscAtmIfVptVccTmAbrOperTable/mscAtmIfVptVccTmAbrOperEntry/mscAtmIfVptVccTmAbrRateIncreaseFactor
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/562/36/2/1/114/9/20/7/2/110/1/14

    Description by mibdepot

    This attribute indicates the Rate Increase Factor (RIF) for this
    connection. The RIF value is computed by using the operational
    value of this attribute, n, as 2 to the inverse power n. For example, if
    the value of this attribute is 6, RIF is 2E-6 = 1/64.

    RIF controls the amount by which the cell transmission rate may
    increase upon receipt of a backward Resource Management (RM)
    cell. For example, if a backward RM cell is received with the
    Congestion Indication (CI) and the No Increase (NI) fields both set
    to 0, the Allowed Cell Rate (ACR) value would be increased by the
    amount (RIF*ACR). The ACR is not allowed to exceed the Peak
    Cell Rate (PCR), in which case the ACR is set to PCR.

    For nailed-up connections, this attribute is determined by the
    provisioned value of the rateIncreaseFactor attribute. For signalled
    connections, it is indicated in the ABR Setup Parameters
    Information Element.

    Parsed from file nortelPC-atmCoreV1.mib.txt
    Company: None
    Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB

    Description by circitor

    This attribute indicates the Rate Increase Factor (RIF) for this
    connection. The RIF value is computed by using the operational
    value of this attribute, n, as 2 to the inverse power n. For example, if
    the value of this attribute is 6, RIF is 2E-6 = 1/64.

    RIF controls the amount by which the cell transmission rate may
    increase upon receipt of a backward Resource Management (RM)
    cell. For example, if a backward RM cell is received with the
    Congestion Indication (CI) and the No Increase (NI) fields both set
    to 0, the Allowed Cell Rate (ACR) value would be increased by the
    amount (RIF*ACR). The ACR is not allowed to exceed the Peak
    Cell Rate (PCR), in which case the ACR is set to PCR.

    For nailed-up connections, this attribute is determined by the
    provisioned value of the rateIncreaseFactor attribute. For signalled
    connections, it is indicated in the ABR Setup Parameters
    Information Element.

    Parsed from file Nortel-MsCarrier-MscPassport-AtmCoreMIB.mib
    Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB

    Information by oid_info

    Vendor: Northern Telecom, Ltd.
    Module: Nortel-MsCarrier-MscPassport-AtmCoreMIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    mscAtmIfVptVccTmAbrRateIncreaseFactor OBJECT-TYPE SYNTAX Unsigned32 (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the Rate Increase Factor (RIF) for this connection. The RIF value is computed by using the operational value of this attribute, n, as 2 to the inverse power n. For example, if the value of this attribute is 6, RIF is 2E-6 = 1/64. RIF controls the amount by which the cell transmission rate may increase upon receipt of a backward Resource Management (RM) cell. For example, if a backward RM cell is received with the Congestion Indication (CI) and the No Increase (NI) fields both set to 0, the Allowed Cell Rate (ACR) value would be increased by the amount (RIF*ACR). The ACR is not allowed to exceed the Peak Cell Rate (PCR), in which case the ACR is set to PCR. For nailed-up connections, this attribute is determined by the provisioned value of the rateIncreaseFactor attribute. For signalled connections, it is indicated in the ABR Setup Parameters Information Element." ::= { mscAtmIfVptVccTmAbrOperEntry 14 }

    Information by circitor

    mscAtmIfVptVccTmAbrRateIncreaseFactor OBJECT-TYPE SYNTAX Unsigned32 (0..15) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the Rate Increase Factor (RIF) for this connection. The RIF value is computed by using the operational value of this attribute, n, as 2 to the inverse power n. For example, if the value of this attribute is 6, RIF is 2E-6 = 1/64. RIF controls the amount by which the cell transmission rate may increase upon receipt of a backward Resource Management (RM) cell. For example, if a backward RM cell is received with the Congestion Indication (CI) and the No Increase (NI) fields both set to 0, the Allowed Cell Rate (ACR) value would be increased by the amount (RIF*ACR). The ACR is not allowed to exceed the Peak Cell Rate (PCR), in which case the ACR is set to PCR. For nailed-up connections, this attribute is determined by the provisioned value of the rateIncreaseFactor attribute. For signalled connections, it is indicated in the ABR Setup Parameters Information Element." ::= { mscAtmIfVptVccTmAbrOperEntry 14 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Sharon Chisholm

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Mike Bobbitt

    Brothers (13)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.10 mscAtmIfVptVccTmAbrInitialCellRate 0 0 This attribute indicates the Initial Cell Rate (ICR) parameter for this
    connection. ICR is the rate at which a source should sen…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.11 mscAtmIfVptVccTmAbrTransientBufferExposure 0 0 This attribute indicates the Transient Buffer Exposure (TBE) for
    this connection. TBE is the negotiated number of cells that the…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.12 mscAtmIfVptVccTmAbrFixedRoundTripTime 0 0 This attribute indicates the Fixed Round-Trip Time (FRTT)
    parameter for this connection. FRTT is the sum of the fixed and
    propaga…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.13 mscAtmIfVptVccTmAbrRateDecreaseFactor 0 0 This attribute indicates the Rate Decrease Factor (RDF) for this
    connection. The RDF value is computed by using the operational
    v…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.15 mscAtmIfVptVccTmAbrMaxCellPerRmCell 0 0 This attribute indicates the maximum number of cells an ABR
    source may transmit for each forward Resource Management (RM)
    cell. T…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.16 mscAtmIfVptVccTmAbrMaxTimeBetweenRmCell 0 0 This attribute indicates the TRM parameter for this connection.

    TRM provides an upper bound on the time interval between forwar…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.17 mscAtmIfVptVccTmAbrCutoffDecreaseFactor 0 0 This attribute indicates the Cutoff Decrease Factor (CDF) parameter
    for this connection. When the value of this attribute is non…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.18 mscAtmIfVptVccTmAbrAcrDecreaseTimeFactor 0 0 This attribute indicates the Allowed Cell Rate Decrease Time Factor
    (ADTF) parameter for this connection.

    ADTF is the time inter…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.19 mscAtmIfVptVccTmAbrForwardRmCellLimit 0 0 This attribute indicates the CRM parameter for this connection.

    CRM is the limit of the number of forward Resource Management
    (R…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.20 mscAtmIfVptVccTmAbrTxRateChangeInfo 0 0 This attribute indicates the rate change information put into the last
    forward Resource Management (RM) cell turned around as a
    b…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.21 mscAtmIfVptVccTmAbrAcrRateChangeInfo 0 0 This attribute indicates the type of change in the Allowed Cell Rate
    (ACR) as a result of the information in the last backward R…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.22 mscAtmIfVptVccTmAbrTxFwdRmCells 0 0 This attribute counts the number of forward Resource Management
    (RM) cells sent over the interface since the last backward RM-ce…
    1.3.6.1.4.1.562.36.2.1.114.9.20.7.2.110.1.23 mscAtmIfVptVccTmAbrRxEfci 0 0 This attribute indicates the value of the Explicit Forward
    Congestion Indication (EFCI) bit of the last data cell received from
    t…