Reference record for OID 1.3.6.1.4.1.562.36.2.1.12.16.11.1.1

Parent
1.3.6.1.4.1.562.36.2.1.12.16.11.1 (mscLpJT2ProvEntry)
Node code
1
Node name
mscLpJT2ClockingSource
Numeric OID
1.3.6.1.4.1.562.36.2.1.12.16.11.1.1
URN notation
urn:oid:1.3.6.1.4.1.562.36.2.1.12.16.11.1.1
Type
OBJECT-TYPE
ASN.1 notation

{1 3 6 1 4 1 562 36 2 1 12 16 11 1 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpJT2(16) mscLpJT2ProvTable(11) mscLpJT2ProvEntry(1) mscLpJT2ClockingSource(1)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/562/36/2/1/12/16/11/1/1
  • /ISO/Identified-Organization/6/1/4/1/562/36/2/1/12/16/11/1/1
  • /ISO/3/6/1/4/1/562/36/2/1/12/16/11/1/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/enterprise/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/enterprises/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/enterprises/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/vendor-objects/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/vendor-objects/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/identified-organization/dod/internet/private/vendor-objects/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/org/dod/internet/private/enterprise/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/org/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/org/dod/internet/private/enterprise/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • /iso/org/dod/internet/private/enterprises/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpJT2/mscLpJT2ProvTable/mscLpJT2ProvEntry/mscLpJT2ClockingSource
  • Additional combinations skipped.

Descriptions

Descriptions may differ between sources. The primary description is shown first.

Primary description: Circitor

This attribute defines the source of the transmit clock for the JT2
line.
When the clocking source is selected from local, the oscillator on
the port generates the clocking for the line.
When the clocking source is selected from line, the port
synchronizes to the clock recovered from the incoming line signal.
When the clocking source is selected from module, the port's clock
synchronizes to the clock provided by the oscillator on the active
CP.
Note:- that when one port is set to local, the other port must also be
set to local, and when one port is set to module, the other port must
also be set to module. If one of the ports is set to line, the other port
must be set to otherPort.
Also, if a CP reference clock is available when the JT2 component
is added, the clocking source defaults to module, whereas if a CP
reference clock is not available when the component is added, the
clocking source defaults to local.

Parsed from file Nortel-MsCarrier-MscPassport-LogicalProcessorMIB.mib
Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

Source file: Download Nortel-MsCarrier-MscPassport-LogicalProcessorMIB — archive MIB indexed for Northern Telecom, Ltd. · Publisher's file Northern Telecom, Ltd. archived MIB 9909010000Z

Native third-party archive copy; vendor association comes from the archive catalog and does not establish a current manufacturer release; Native LAST-UPDATED: 9909010000Z; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:21:03 GMT; 1.1 MiB

Vendor MIB copy from the MibBrowser.online archive. Northern Telecom, Ltd. support.

Related source files and packages:

Show all 4 related files and packages
  • RFC-1212 — dependency MIB (MibBrowser.online)Native third-party archive dependency for Northern Telecom, Ltd. MIB imports; authorship is not attributed to that manufacturer; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:21:17 GMT; 2,948 bytes

Source file: Download Nortel-MsCarrier-MscPassport-LogicalProcessorMIB.mib

Publisher path: Mibs; 1.1 MiB

Alternative description: MIBdepot

This attribute defines the source of the transmit clock for the JT2
line.
When the clocking source is selected from local, the oscillator on
the port generates the clocking for the line.
When the clocking source is selected from line, the port
synchronizes to the clock recovered from the incoming line signal.
When the clocking source is selected from module, the port's clock
synchronizes to the clock provided by the oscillator on the active
CP.
Note:- that when one port is set to local, the other port must also be
set to local, and when one port is set to module, the other port must
also be set to module. If one of the ports is set to line, the other port
must be set to otherPort.
Also, if a CP reference clock is available when the JT2 component
is added, the clocking source defaults to module, whereas if a CP
reference clock is not available when the component is added, the
clocking source defaults to local.

Source file: Download nortelPC-logicalProcessorV1.mib.txt

File: nortel/nortelPC-logicalProcessorV1.mib.txt; 1.1 MiB

Information from OID Repository

Vendor: Northern Telecom, Ltd.
Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

[Automatically extracted from oidview.com]

Information from MIBdepot

mscLpJT2ClockingSource OBJECT-TYPE
   SYNTAX     INTEGER  {
                 local(0),
                 line(1),
                 module(2),
                 otherPort(4) }
   ACCESS     read-write
   STATUS     mandatory
   DESCRIPTION
     "This attribute defines the source of the transmit clock for the JT2 
      line.
      When the clocking source is selected from local, the oscillator on 
      the port generates the clocking for the line.
      When the clocking source is selected from line, the port 
      synchronizes to the clock recovered from the incoming line signal.
      When the clocking source is selected from module, the port's clock 
      synchronizes to the clock provided by the oscillator on the active 
      CP.
      Note:- that when one port is set to local, the other port must also be 
      set to local, and when one port is set to module, the other port must 
      also be set to module. If one of the ports is set to line, the other port 
      must be set to otherPort.
      Also, if a CP reference clock is available when the JT2 component 
      is added, the clocking source defaults to module, whereas if a CP 
      reference clock is not available when the component is added, the 
      clocking source defaults to local."
::= { mscLpJT2ProvEntry 1 }

Information from Circitor

mscLpJT2ClockingSource OBJECT-TYPE
   SYNTAX     INTEGER  {
                 local(0),
                 line(1),
                 module(2),
                 otherPort(4) }
   ACCESS     read-write
   STATUS     mandatory
   DESCRIPTION
     "This attribute defines the source of the transmit clock for the JT2 
      line.
      When the clocking source is selected from local, the oscillator on 
      the port generates the clocking for the line.
      When the clocking source is selected from line, the port 
      synchronizes to the clock recovered from the incoming line signal.
      When the clocking source is selected from module, the port's clock 
      synchronizes to the clock provided by the oscillator on the active 
      CP.
      Note:- that when one port is set to local, the other port must also be 
      set to local, and when one port is set to module, the other port must 
      also be set to module. If one of the ports is set to line, the other port 
      must be set to otherPort.
      Also, if a CP reference clock is available when the JT2 component 
      is added, the clocking source defaults to module, whereas if a CP 
      reference clock is not available when the component is added, the 
      clocking source defaults to local."
::= { mscLpJT2ProvEntry 1 }

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.562)

Sharon Chisholm

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.562)

Mike Bobbitt

Siblings (2)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.562.36.2.1.12.16.11.1.2 mscLpJT2LineLength00 This attribute defines the line length for equalization calculations
for the JT2 line. The range is between 0 and 480 feet (1 me…
1.3.6.1.4.1.562.36.2.1.12.16.11.1.3 mscLpJT2ApplicationFramerName00 This attribute defines the link to the software stack. It defines which
application is running on top of the JT2 component.