This attribute indicates whether a LOF (Loss of Frame) alarm state
has been entered. The LOF alarm state is entered when LOF defects
(for DS1: 2 out of 5 framing bits in error; for E1: 3 consecutive
frame alignment patterns in error) have been detected for 3 seconds
+/- 0.5 second . If the LOF defects are intermittently occurring, the
LOF defect accumulator is decremented at a rate of 1/10 of the
incrementing rate (alarm integration ratio of 1/10), with all
measurements based on a 200 ms polling cycle.
The port goes into an operational state of disabled until the LOF
alarm state is cleared. The condition is cleared when framing has
been achieved for 10 seconds +/- 0.5 second.
Parsed from file nortelPC-externalTimingE1V1.mib.txt
Company: None
Module: Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB
This attribute indicates whether a LOF (Loss of Frame) alarm state
has been entered. The LOF alarm state is entered when LOF defects
(for DS1: 2 out of 5 framing bits in error; for E1: 3 consecutive
frame alignment patterns in error) have been detected for 3 seconds
+/- 0.5 second . If the LOF defects are intermittently occurring, the
LOF defect accumulator is decremented at a rate of 1/10 of the
incrementing rate (alarm integration ratio of 1/10), with all
measurements based on a 200 ms polling cycle.
The port goes into an operational state of disabled until the LOF
alarm state is cleared. The condition is cleared when framing has
been achieved for 10 seconds +/- 0.5 second.
Parsed from file Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB.mib
Module: Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB
Vendor: Northern Telecom, Ltd.
Module: Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB
[Automatically extracted from oidview.com]
mscLpEE1LofAlarm OBJECT-TYPE SYNTAX INTEGER { on(0), off(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether a LOF (Loss of Frame) alarm state has been entered. The LOF alarm state is entered when LOF defects (for DS1: 2 out of 5 framing bits in error; for E1: 3 consecutive frame alignment patterns in error) have been detected for 3 seconds +/- 0.5 second . If the LOF defects are intermittently occurring, the LOF defect accumulator is decremented at a rate of 1/10 of the incrementing rate (alarm integration ratio of 1/10), with all measurements based on a 200 ms polling cycle. The port goes into an operational state of disabled until the LOF alarm state is cleared. The condition is cleared when framing has been achieved for 10 seconds +/- 0.5 second." DEFVAL { off } ::= { mscLpEE1OperEntry 2 }
mscLpEE1LofAlarm OBJECT-TYPE SYNTAX INTEGER { on(0), off(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether a LOF (Loss of Frame) alarm state has been entered. The LOF alarm state is entered when LOF defects (for DS1: 2 out of 5 framing bits in error; for E1: 3 consecutive frame alignment patterns in error) have been detected for 3 seconds +/- 0.5 second . If the LOF defects are intermittently occurring, the LOF defect accumulator is decremented at a rate of 1/10 of the incrementing rate (alarm integration ratio of 1/10), with all measurements based on a 200 ms polling cycle. The port goes into an operational state of disabled until the LOF alarm state is cleared. The condition is cleared when framing has been achieved for 10 seconds +/- 0.5 second." DEFVAL { off } ::= { mscLpEE1OperEntry 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.562.36.2.1.12.29.16.1.1 | mscLpEE1LosAlarm | 0 | 0 | This attribute indicates whether a LOS (Loss of Signal) alarm state has been entered. A LOS alarm is declared after LOS defects … |
1.3.6.1.4.1.562.36.2.1.12.29.16.1.3 | mscLpEE1RxAisAlarm | 0 | 0 | This attribute indicates whether an AIS (Alarm Indication Signal) alarm has been entered. The AIS Alarm state is entered when AI… |