Reference record for OID 1.3.6.1.4.1.562.36.2.1.12.5.10.1.3



parent
1.3.6.1.4.1.562.36.2.1.12.5.10.1 (mscLpDS3ProvEntry)
node code
3
node name
mscLpDS3ClockingSource
dot oid
1.3.6.1.4.1.562.36.2.1.12.5.10.1.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3ProvTable(10) mscLpDS3ProvEntry(1) mscLpDS3ClockingSource(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3ProvTable(10) mscLpDS3ProvEntry(1) mscLpDS3ClockingSource(3)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3ProvTable(10) mscLpDS3ProvEntry(1) mscLpDS3ClockingSource(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3ProvTable(10) mscLpDS3ProvEntry(1) mscLpDS3ClockingSource(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3ProvTable(10) mscLpDS3ProvEntry(1) mscLpDS3ClockingSource(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3ProvTable(10) mscLpDS3ProvEntry(1) mscLpDS3ClockingSource(3)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3ProvTable(10) mscLpDS3ProvEntry(1) mscLpDS3ClockingSource(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3ProvTable(10) mscLpDS3ProvEntry(1) mscLpDS3ClockingSource(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3ProvTable/mscLpDS3ProvEntry/mscLpDS3ClockingSource
  • /iso/identified-organization/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3ProvTable/mscLpDS3ProvEntry/mscLpDS3ClockingSource
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3ProvTable/mscLpDS3ProvEntry/mscLpDS3ClockingSource
  • /iso/org/dod/internet/private/enterprise/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3ProvTable/mscLpDS3ProvEntry/mscLpDS3ClockingSource
  • /iso/org/dod/internet/private/enterprises/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3ProvTable/mscLpDS3ProvEntry/mscLpDS3ClockingSource
  • /iso/org/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3ProvTable/mscLpDS3ProvEntry/mscLpDS3ClockingSource
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3ProvTable/mscLpDS3ProvEntry/mscLpDS3ClockingSource
  • /iso/iso-identified-organization/dod/internet/private/enterprises/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3ProvTable/mscLpDS3ProvEntry/mscLpDS3ClockingSource
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/562/36/2/1/12/5/10/1/3

    Description by mibdepot

    This attribute defines the type of clocking source used for
    synchronizing the DS3 transmit clock: local means direct use of the
    local clock oscillator at its centre frequency; line means use of a
    signal phase-locked to the incoming DS3 line rate; module means
    the use of a signal phase-locked to the CP reference clock.
    Note that the multiport cell-based cards have one common clock
    source for all ports. For this reason, the following rules apply for the
    value of clockingSource across the board's three ports:
    All three clockingSource values must be 'local' OR
    All three clockingSource values must be 'module' OR
    One clockingSource value must be 'line' and the other two must be
    'otherPort'.
    If there is no NS component provisioned, the default value for this
    attribute will be local. If the NS component has been provisioned,
    the default value is module, except for the 1pDS3C cards.
    For the 1pDS3C cards, the default and only valid value for this
    attribute is local. The clockingSource of the DS1 sub-component
    becomes the effective clocking source for this attribute. All the DS1
    sub-components have the same clocking source.

    Parsed from file nortelPC-logicalProcessorV1.mib.txt
    Company: None
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    Description by circitor

    This attribute defines the type of clocking source used for
    synchronizing the DS3 transmit clock: local means direct use of the
    local clock oscillator at its centre frequency; line means use of a
    signal phase-locked to the incoming DS3 line rate; module means
    the use of a signal phase-locked to the CP reference clock.
    Note that the multiport cell-based cards have one common clock
    source for all ports. For this reason, the following rules apply for the
    value of clockingSource across the board's three ports:
    All three clockingSource values must be 'local' OR
    All three clockingSource values must be 'module' OR
    One clockingSource value must be 'line' and the other two must be
    'otherPort'.
    If there is no NS component provisioned, the default value for this
    attribute will be local. If the NS component has been provisioned,
    the default value is module, except for the 1pDS3C cards.
    For the 1pDS3C cards, the default and only valid value for this
    attribute is local. The clockingSource of the DS1 sub-component
    becomes the effective clocking source for this attribute. All the DS1
    sub-components have the same clocking source.

    Parsed from file Nortel-MsCarrier-MscPassport-LogicalProcessorMIB.mib
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    Information by oid_info

    Vendor: Northern Telecom, Ltd.
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    mscLpDS3ClockingSource OBJECT-TYPE SYNTAX INTEGER { local(0), line(1), module(2), otherPort(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines the type of clocking source used for synchronizing the DS3 transmit clock: local means direct use of the local clock oscillator at its centre frequency; line means use of a signal phase-locked to the incoming DS3 line rate; module means the use of a signal phase-locked to the CP reference clock. Note that the multiport cell-based cards have one common clock source for all ports. For this reason, the following rules apply for the value of clockingSource across the board's three ports: All three clockingSource values must be 'local' OR All three clockingSource values must be 'module' OR One clockingSource value must be 'line' and the other two must be 'otherPort'. If there is no NS component provisioned, the default value for this attribute will be local. If the NS component has been provisioned, the default value is module, except for the 1pDS3C cards. For the 1pDS3C cards, the default and only valid value for this attribute is local. The clockingSource of the DS1 sub-component becomes the effective clocking source for this attribute. All the DS1 sub-components have the same clocking source." ::= { mscLpDS3ProvEntry 3 }

    Information by circitor

    mscLpDS3ClockingSource OBJECT-TYPE SYNTAX INTEGER { local(0), line(1), module(2), otherPort(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines the type of clocking source used for synchronizing the DS3 transmit clock: local means direct use of the local clock oscillator at its centre frequency; line means use of a signal phase-locked to the incoming DS3 line rate; module means the use of a signal phase-locked to the CP reference clock. Note that the multiport cell-based cards have one common clock source for all ports. For this reason, the following rules apply for the value of clockingSource across the board's three ports: All three clockingSource values must be 'local' OR All three clockingSource values must be 'module' OR One clockingSource value must be 'line' and the other two must be 'otherPort'. If there is no NS component provisioned, the default value for this attribute will be local. If the NS component has been provisioned, the default value is module, except for the 1pDS3C cards. For the 1pDS3C cards, the default and only valid value for this attribute is local. The clockingSource of the DS1 sub-component becomes the effective clocking source for this attribute. All the DS1 sub-components have the same clocking source." ::= { mscLpDS3ProvEntry 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Sharon Chisholm

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Mike Bobbitt

    Brothers (4)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.562.36.2.1.12.5.10.1.1 mscLpDS3CbitParity 0 0 This attribute indicates if C-Bit parity has been turned ON or OFF.
    The CBIT component will appear under the DS3 component when
    t…
    1.3.6.1.4.1.562.36.2.1.12.5.10.1.2 mscLpDS3LineLength 0 0 This attribute defines the line length for equalization calculations
    for the DS3 line. The range is between 0 and 450 feet (1 me…
    1.3.6.1.4.1.562.36.2.1.12.5.10.1.4 mscLpDS3ApplicationFramerName 0 0 This attribute defines the link to the software stack. It defines which
    application is running on top of the DS3 component.
    1.3.6.1.4.1.562.36.2.1.12.5.10.1.5 mscLpDS3Mapping 0 0 This attribute indicates if ATM cells will be mapped directly into
    the DS3 payload, or whether PLCP mapping will be used. The
    PLC…