Reference record for OID 1.3.6.1.4.1.562.36.2.1.12.5.6.2.2.11.1.2




parent
1.3.6.1.4.1.562.36.2.1.12.5.6.2.2.11.1 (mscLpDS3DS1ChanTestSetupEntry)
node code
2
node name
mscLpDS3DS1ChanTestType
dot oid
1.3.6.1.4.1.562.36.2.1.12.5.6.2.2.11.1.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1Chan(2) mscLpDS3DS1ChanTest(2) mscLpDS3DS1ChanTestSetupTable(11) mscLpDS3DS1ChanTestSetupEntry(1) mscLpDS3DS1ChanTestType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1Chan(2) mscLpDS3DS1ChanTest(2) mscLpDS3DS1ChanTestSetupTable(11) mscLpDS3DS1ChanTestSetupEntry(1) mscLpDS3DS1ChanTestType(2)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1Chan(2) mscLpDS3DS1ChanTest(2) mscLpDS3DS1ChanTestSetupTable(11) mscLpDS3DS1ChanTestSetupEntry(1) mscLpDS3DS1ChanTestType(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1Chan(2) mscLpDS3DS1ChanTest(2) mscLpDS3DS1ChanTestSetupTable(11) mscLpDS3DS1ChanTestSetupEntry(1) mscLpDS3DS1ChanTestType(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1Chan(2) mscLpDS3DS1ChanTest(2) mscLpDS3DS1ChanTestSetupTable(11) mscLpDS3DS1ChanTestSetupEntry(1) mscLpDS3DS1ChanTestType(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1Chan(2) mscLpDS3DS1ChanTest(2) mscLpDS3DS1ChanTestSetupTable(11) mscLpDS3DS1ChanTestSetupEntry(1) mscLpDS3DS1ChanTestType(2)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1Chan(2) mscLpDS3DS1ChanTest(2) mscLpDS3DS1ChanTestSetupTable(11) mscLpDS3DS1ChanTestSetupEntry(1) mscLpDS3DS1ChanTestType(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1Chan(2) mscLpDS3DS1ChanTest(2) mscLpDS3DS1ChanTestSetupTable(11) mscLpDS3DS1ChanTestSetupEntry(1) mscLpDS3DS1ChanTestType(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1Chan/mscLpDS3DS1ChanTest/mscLpDS3DS1ChanTestSetupTable/mscLpDS3DS1ChanTestSetupEntry/mscLpDS3DS1ChanTestType
  • /iso/identified-organization/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1Chan/mscLpDS3DS1ChanTest/mscLpDS3DS1ChanTestSetupTable/mscLpDS3DS1ChanTestSetupEntry/mscLpDS3DS1ChanTestType
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1Chan/mscLpDS3DS1ChanTest/mscLpDS3DS1ChanTestSetupTable/mscLpDS3DS1ChanTestSetupEntry/mscLpDS3DS1ChanTestType
  • /iso/org/dod/internet/private/enterprise/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1Chan/mscLpDS3DS1ChanTest/mscLpDS3DS1ChanTestSetupTable/mscLpDS3DS1ChanTestSetupEntry/mscLpDS3DS1ChanTestType
  • /iso/org/dod/internet/private/enterprises/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1Chan/mscLpDS3DS1ChanTest/mscLpDS3DS1ChanTestSetupTable/mscLpDS3DS1ChanTestSetupEntry/mscLpDS3DS1ChanTestType
  • /iso/org/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1Chan/mscLpDS3DS1ChanTest/mscLpDS3DS1ChanTestSetupTable/mscLpDS3DS1ChanTestSetupEntry/mscLpDS3DS1ChanTestType
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1Chan/mscLpDS3DS1ChanTest/mscLpDS3DS1ChanTestSetupTable/mscLpDS3DS1ChanTestSetupEntry/mscLpDS3DS1ChanTestType
  • /iso/iso-identified-organization/dod/internet/private/enterprises/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1Chan/mscLpDS3DS1ChanTest/mscLpDS3DS1ChanTestSetupTable/mscLpDS3DS1ChanTestSetupEntry/mscLpDS3DS1ChanTestType
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/562/36/2/1/12/5/6/2/2/11/1/2

    Description by mibdepot

    This attribute is the type of test to be run. The available test types
    include the following:
    card test sets up an internal loop on the board and runs a bit error
    rate test.
    manual test assumes the line is looped back externally and a bit
    error rate test is performed.
    localLoop test loops back the local modem and performs a bit error
    rate test.
    remoteLoop test loops back the remote modem (or CSU) and
    performs a bit error rate test.
    externalLoop test loops back the line to the far end.
    payloadLoop test only loops back the payload data received from
    the incoming line.
    remoteLoopThisTrib loops this particular tributary back at the far
    end, using services provided by the parent.
    v54RemoteLoop initiates a V.54 Remote Loopback test.
    pn127RemoteLoop initiates a PN127 Remote Loopback test.
    Note that not all test types are not supported by all function
    processors.

    Parsed from file nortelPC-logicalProcessorV1.mib.txt
    Company: None
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    Description by circitor

    This attribute is the type of test to be run. The available test types
    include the following:
    card test sets up an internal loop on the board and runs a bit error
    rate test.
    manual test assumes the line is looped back externally and a bit
    error rate test is performed.
    localLoop test loops back the local modem and performs a bit error
    rate test.
    remoteLoop test loops back the remote modem (or CSU) and
    performs a bit error rate test.
    externalLoop test loops back the line to the far end.
    payloadLoop test only loops back the payload data received from
    the incoming line.
    remoteLoopThisTrib loops this particular tributary back at the far
    end, using services provided by the parent.
    v54RemoteLoop initiates a V.54 Remote Loopback test.
    pn127RemoteLoop initiates a PN127 Remote Loopback test.
    Note that not all test types are not supported by all function
    processors.

    Parsed from file Nortel-MsCarrier-MscPassport-LogicalProcessorMIB.mib
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    Information by oid_info

    Vendor: Northern Telecom, Ltd.
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    mscLpDS3DS1ChanTestType OBJECT-TYPE SYNTAX INTEGER { card(0), manual(1), localLoop(2), remoteLoop(3), externalLoop(4), payloadLoop(5), remoteLoopThisTrib(6), v54RemoteLoop(7), pn127RemoteLoop(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is the type of test to be run. The available test types include the following: card test sets up an internal loop on the board and runs a bit error rate test. manual test assumes the line is looped back externally and a bit error rate test is performed. localLoop test loops back the local modem and performs a bit error rate test. remoteLoop test loops back the remote modem (or CSU) and performs a bit error rate test. externalLoop test loops back the line to the far end. payloadLoop test only loops back the payload data received from the incoming line. remoteLoopThisTrib loops this particular tributary back at the far end, using services provided by the parent. v54RemoteLoop initiates a V.54 Remote Loopback test. pn127RemoteLoop initiates a PN127 Remote Loopback test. Note that not all test types are not supported by all function processors." DEFVAL { card } ::= { mscLpDS3DS1ChanTestSetupEntry 2 }

    Information by circitor

    mscLpDS3DS1ChanTestType OBJECT-TYPE SYNTAX INTEGER { card(0), manual(1), localLoop(2), remoteLoop(3), externalLoop(4), payloadLoop(5), remoteLoopThisTrib(6), v54RemoteLoop(7), pn127RemoteLoop(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is the type of test to be run. The available test types include the following: card test sets up an internal loop on the board and runs a bit error rate test. manual test assumes the line is looped back externally and a bit error rate test is performed. localLoop test loops back the local modem and performs a bit error rate test. remoteLoop test loops back the remote modem (or CSU) and performs a bit error rate test. externalLoop test loops back the line to the far end. payloadLoop test only loops back the payload data received from the incoming line. remoteLoopThisTrib loops this particular tributary back at the far end, using services provided by the parent. v54RemoteLoop initiates a V.54 Remote Loopback test. pn127RemoteLoop initiates a PN127 Remote Loopback test. Note that not all test types are not supported by all function processors." DEFVAL { card } ::= { mscLpDS3DS1ChanTestSetupEntry 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Sharon Chisholm

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Mike Bobbitt

    Brothers (7)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.562.36.2.1.12.5.6.2.2.11.1.1 mscLpDS3DS1ChanTestPurpose 0 0 This attribute records the purpose of the test so that the test results
    can be associated and properly analyzed.
    1.3.6.1.4.1.562.36.2.1.12.5.6.2.2.11.1.3 mscLpDS3DS1ChanTestFrmSize 0 0 This attribute defines the size of the test data frames in number of
    bytes.
    1.3.6.1.4.1.562.36.2.1.12.5.6.2.2.11.1.4 mscLpDS3DS1ChanTestFrmPatternType 0 0 This attribute defines the type of data pattern generation to use. The
    following lists the available pattern types:
    ccitt32kBitPa…
    1.3.6.1.4.1.562.36.2.1.12.5.6.2.2.11.1.5 mscLpDS3DS1ChanTestCustomizedPattern 0 0 This attribute allows a customized 32 bit pattern to be defined for
    use in the test data frames. This attribute is used when the…
    1.3.6.1.4.1.562.36.2.1.12.5.6.2.2.11.1.6 mscLpDS3DS1ChanTestDataStartDelay 0 0 This attribute specifies the time delay (in seconds) between when
    the test expects the loop to have been set up, to when the tes…
    1.3.6.1.4.1.562.36.2.1.12.5.6.2.2.11.1.7 mscLpDS3DS1ChanTestDisplayInterval 0 0 This attribute defines the interval (in minutes) between which
    interim test results are to be displayed. Results are displayed a…
    1.3.6.1.4.1.562.36.2.1.12.5.6.2.2.11.1.8 mscLpDS3DS1ChanTestDuration 0 0 This attribute is the duration (in minutes) that test data will be
    transmitted. In the case of an externalLoop, this is the time…