This object reflects the desired status of the SNA
Switching module. If this value is set to 'down',
SNA Switching is disabled. If this value is set to
'up', SNA Switching is enabled.
Parsed from file FC_FASTC.MIB.txt
Company: None
Module: FC-FASTC-MIB
This object reflects the desired status of the SNA
Switching module. If this value is set to 'down',
SNA Switching is disabled. If this value is set to
'up', SNA Switching is enabled.
Parsed from file FC-FASTC-MIB.mib
Module: FC-FASTC-MIB
Vendor: Encore Networks, Inc.
Module: FC-FASTC-MIB
[Automatically extracted from oidview.com]
fsSnaAdminStatus OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object reflects the desired status of the SNA Switching module. If this value is set to 'down', SNA Switching is disabled. If this value is set to 'up', SNA Switching is enabled." ::= { fsSna 1 }
fsSnaAdminStatus OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object reflects the desired status of the SNA Switching module. If this value is set to 'down', SNA Switching is disabled. If this value is set to 'up', SNA Switching is enabled." ::= { fsSna 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.635.1.2.1.2.7.1.0 | fsSnaAdminStatus | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.635.1.2.1.2.7.2 | fsSnaSwTstXidRetries | 1 | 1 | This object reflects the maximum number of retries permitted for TEST and XID pdus. |
1.3.6.1.4.1.635.1.2.1.2.7.3 | fsSnaSwTstXidTmr | 1 | 1 | This object reflects the value of the XID-TEST timer in seconds. |
1.3.6.1.4.1.635.1.2.1.2.7.4 | fsSnaSessRestartTmr | 1 | 1 | This object reflects the value of the Session-Restart timer in seconds. |
1.3.6.1.4.1.635.1.2.1.2.7.8 | fsSnaPseudoBridgeNumber | 1 | 1 | The pseudo-bridge number for the FRAD |
1.3.6.1.4.1.635.1.2.1.2.7.9 | fsSnaPseudoRingNumber | 1 | 1 | The pseudo-ring number for the FRAD |
1.3.6.1.4.1.635.1.2.1.2.7.10 | fsSnaSdlcFrCfgTable | 1 | 14 | Configuration Table for SDLC-FR Switching. This table would contain the SDLC-FR switching entries, indexed by the table index 'fs… |
1.3.6.1.4.1.635.1.2.1.2.7.11 | fsSnaLlcFrCfgTable | 1 | 13 | Configuration Table for LLC-FR Switching. This table would contain the LLC-FR switching entries, indexed by the table index 'fsSn… |
1.3.6.1.4.1.635.1.2.1.2.7.12 | fsSnaSdlcLlcCfgTable | 1 | 13 | Configuration Table for SDLC-LLC Switching. This table would contain the SDLC-LLC switching entries, indexed by the table index '… |