This is the line type.
Parsed from file ADN-ENV-MIB.mib
Module: ADN-ENV-MIB
Vendor: Alcatel-Lucent (previously was 'Alcatel Data Network')
Module: ADN-ENV-MIB
[Automatically extracted from oidview.com]
adnAtmLinePerfLineType OBJECT-TYPE SYNTAX INTEGER { atmDs3(1), atmE3(2), atmSonet(3), atmSdh(4), atmDs1(5), atmE1(6), cesDs1(7), cesE1(8) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the line type." ::= { adnAtmLinePerfEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.637.3.1.8.5.5.23.1.2 | adnAtmLinePerfBlocksPerSec | 0 | 0 | This indicates the number of blocks sent and received per second. |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.3 | adnAtmLinePerfLowErrBlockThr | 0 | 0 | This indicates the low second error block threshold; the value range of this threshold is 1..adnAtmLinePerfHighErrBlockThr. |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.4 | adnAtmLinePerfHighErrBlockThr | 0 | 0 | This indicates the high second error block threshold; the value range of this threshold is 1..adnAtmLinePerfBlocksPerSec. |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.5 | adnAtmLinePerfBegUnAvailable | 0 | 0 | This indicates the number of consecutive severely erroned seconds necessary to declare the beginning of an unavailable period. |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.6 | adnAtmLinePerfEndUnAvailable | 0 | 0 | This indicates the number of consecutive non severely erroned seconds necessary to declare the ending of the unavailable period. |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.7 | adnAtmLinePerfConsSeverErrSec | 0 | 0 | This indicates the number of consecutive severely errored seconds used for the F3 maintenance flow calculation. |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.8 | adnAtmLinePerfHighBBE15Thr | 0 | 0 | This indicates the high threshold for background block error on 1/4 hour period; the value range of this threshold is 0..900*adnAt… |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.9 | adnAtmLinePerfHighES15Thr | 0 | 0 | This indicates the high threshold for errored second on 1/4 hour period; the value range of this threshold is 0..900. |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.10 | adnAtmLinePerfHighSES15Thr | 0 | 0 | This indicates the high threshold for severely errored second on 1/4 hour period; the value range of this threshold is 0..900. |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.11 | adnAtmLinePerfLowBBE15Thr | 0 | 0 | This indicates the low threshold for background block error on 1/4 hour period; the value range of this threshold is 0..adnAtmLine… |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.12 | adnAtmLinePerfLowES15Thr | 0 | 0 | This indicates the low threshold for errored second on 1/4 hour period; the value range of this threshold is 0..adnAtmLinePerfHigh… |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.13 | adnAtmLinePerfLowSES15Thr | 0 | 0 | This indicates the low threshold for severely errored second on 1/4 hour period; the value range of this threshold is 0..adnAtmLin… |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.14 | adnAtmLinePerfBBE24Thr | 0 | 0 | This indicates the threshold for background block error on 24 hours period; the value range of this threshold is 0..86400*adnAtmLi… |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.15 | adnAtmLinePerfES24Thr | 0 | 0 | This indicates the threshold for errored second on 24 hours period; the value range of this threshold is 0..86400. |
1.3.6.1.4.1.637.3.1.8.5.5.23.1.16 | adnAtmLinePerfSES24Thr | 0 | 0 | This indicates the threshold for severely errored second on 24 hours period; the value range of this threshold is 0..86400. |