This is the Unique ID for this chassis, if it exists.
Parsed from file dellserv_basebrdd.mib.txt
Company: None
Module: BASEBRDD_MIB-MIB
This is the Unique ID for this chassis, if it exists.
Parsed from file BASEBRDD-MIB-MIB.mib
Module: BASEBRDD-MIB-MIB
Vendor: Dell Inc.
Module: BASEBRDD_MIB-MIB
[Automatically extracted from oidview.com]
chassUidAtt14 OBJECT-TYPE SYNTAX DmiDisplaystring ACCESS read-only STATUS mandatory DESCRIPTION "This is the Unique ID for this chassis, if it exists." REFERENCE "'Dell|SystemChassisExtension|004' 14" ::= { dellSystemChassisExtensionEntry 14 }
chassUidAtt14 OBJECT-TYPE SYNTAX DmiDisplaystring ACCESS read-only STATUS mandatory DESCRIPTION "This is the Unique ID for this chassis, if it exists." REFERENCE "'Dell|SystemChassisExtension|004' 14" ::= { dellSystemChassisExtensionEntry 14 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.674.10891.306.1.0 | dellSystemChassisExtensionState | 0 | 0 | " REFERENCE "'Dell|SystemChassisExtension|004' 0 |
1.3.6.1.4.1.674.10891.306.1.1 | chassIndexAtt1 | 0 | 0 | Physical container index |
1.3.6.1.4.1.674.10891.306.1.2 | chassGlobStatusAtt2 | 0 | 0 | Global status of all devices in chassis. |
1.3.6.1.4.1.674.10891.306.1.3 | chassTempStatusAtt3 | 0 | 0 | Global status of temperature probes. |
1.3.6.1.4.1.674.10891.306.1.4 | chassTempProbesAtt4 | 0 | 0 | This contains the statuses of all temp probes in the system, one probe per octet. The value of each octet is the value of the s… |
1.3.6.1.4.1.674.10891.306.1.5 | chassFansStatusAtt5 | 0 | 0 | Global status of fan sensors. |
1.3.6.1.4.1.674.10891.306.1.6 | chassFansProbesAtt6 | 0 | 0 | This contains the statuses of all fan probes in the system, one probe per octet. The value of each octet is the value of the st… |
1.3.6.1.4.1.674.10891.306.1.7 | chassVoltStatusAtt7 | 0 | 0 | Global status of voltage probes. |
1.3.6.1.4.1.674.10891.306.1.8 | chassVoltProbesAtt8 | 0 | 0 | This contains the statuses of all volt probes in the system, one probe per octet. The value of each octet is the value of the s… |
1.3.6.1.4.1.674.10891.306.1.9 | chassAmpStatusAtt9 | 0 | 0 | Global status of current probes. |
1.3.6.1.4.1.674.10891.306.1.10 | chassAmpProbesAtt10 | 0 | 0 | This contains the statuses of all amp probes in the system, one probe per octet. The value of each octet is the value of the st… |
1.3.6.1.4.1.674.10891.306.1.11 | chassPsStatusAtt11 | 0 | 0 | Global status of power supplies. |
1.3.6.1.4.1.674.10891.306.1.12 | chassPwrSuppliesAtt12 | 0 | 0 | This contains the statuses of all power supplies in the system, one probe per octet. The value of each octet is the value of th… |
1.3.6.1.4.1.674.10891.306.1.13 | chassServiceTagAtt13 | 0 | 0 | This is the service tag for this chassis, if it exists. |
1.3.6.1.4.1.674.10891.306.1.15 | chassBackPlaneUidAtt15 | 0 | 0 | This is the Unique ID for the backplane in this chassis. |
1.3.6.1.4.1.674.10891.306.1.16 | chassIdentifyAtt16 | 0 | 0 | This attribute is used to visually identify a disk pod or other chassis by causing its lights to flash. Setting this value to no… |
1.3.6.1.4.1.674.10891.306.1.17 | chassFanControlAtt17 | 0 | 0 | This attribute is used to control the fan speed in a chassis. If the value is 0, then fan control is notavailable. A value of 2… |
1.3.6.1.4.1.674.10891.306.1.18 | chassLEDConfigAtt18 | 0 | 0 | This attribute is used to configure which fault conditionscause the fault LED to flash. If the value is 0, thenthis feature is … |
1.3.6.1.4.1.674.10891.306.1.19 | chassFaultClearAtt19 | 0 | 0 | This attribute is used to clear the hard drive fault LED.If this value is non-zero, then it is available. Writingany value to t… |
1.3.6.1.4.1.674.10891.306.1.20 | chassThermalShutdownAtt20 | 0 | 0 | This attribute is used to enable thermal shutdown of a chassis. If the value is -1, then thermal shutdown is notenabled. A valu… |
1.3.6.1.4.1.674.10891.306.1.21 | chassMemStatusAtt21 | 0 | 0 | Global status of Memory Devices. |
1.3.6.1.4.1.674.10891.306.1.22 | chassMemDevicesAtt22 | 0 | 0 | This contains the statuses of all memory devices in the system, one device per octet. The value of each octet is the value of t… |