Reference record for OID 1.3.6.1.4.1.674.10893.1.1.130.4.1.4

Parent
1.3.6.1.4.1.674.10893.1.1.130.4.1 (arrayDiskEntry)
Node code
4
Node name
arrayDiskState
Numeric OID
1.3.6.1.4.1.674.10893.1.1.130.4.1.4
URN notation
urn:oid:1.3.6.1.4.1.674.10893.1.1.130.4.1.4
Type
OBJECT-TYPE
ASN.1 notation

{1 3 6 1 4 1 674 10893 1 1 130 4 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dell(674) storage(10893) software(1) arrayManager(1) physicalDevices(130) arrayDiskTable(4) arrayDiskEntry(1) arrayDiskState(4)}
OID-IRI notation
  • /1/3/6/1/4/1/674/10893/1/1/130/4/1/4
  • /ISO/Identified-Organization/6/1/4/1/674/10893/1/1/130/4/1/4
  • /ISO/3/6/1/4/1/674/10893/1/1/130/4/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/identified-organization/dod/internet/private/enterprises/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/identified-organization/dod/internet/private/vendor-objects/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/org/dod/internet/private/enterprise/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/org/dod/internet/private/enterprises/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/org/dod/internet/private/ldap-enterprise/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/org/dod/internet/private/vendor-objects/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/iso-identified-organization/dod/internet/private/enterprise/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/iso-identified-organization/dod/internet/private/enterprises/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/iso-organization/dod/internet/private/enterprise/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/iso-organization/dod/internet/private/enterprises/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState
  • /iso/iso-organization/dod/internet/private/vendor-objects/dell/storage/software/arrayManager/physicalDevices/arrayDiskTable/arrayDiskEntry/arrayDiskState

Descriptions

Descriptions may differ between sources. The primary description is shown first.

Primary description: MIBdepot

The current state of the array disk.
Possible states:
0: Unknown
1: Ready - Operational.
2: Failed - Not operational.
3: Online - Operational.
4: Offline - The drive is not available to the RAID controller.
6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk.
7: Recovering - Refers to state of recovering from bad blocks on disks.
11: Removed - Indicates that array disk has been removed.
15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency.
24: Rebuild
25: No Media - CD-ROM or removable disk has no media.
26: Formatting - In the process of formatting.
28: Diagnostics - Diagnostics are running.
35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers.


Parsed from file arymgr.mib.txt
Company: dell
Module: ArrayManager-MIB

Source file: Download arymgr.mib.txt

File: dell/arymgr.mib.txt; 265,184 bytes

arrayDiskState — MIBdepot

The current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller. 6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk. 7: Recovering - Refers to state of recovering from bad blocks on disks. 11: Removed - Indicates that array disk has been removed. 15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency. 24: Rebuild 25: No Media - CD-ROM or removable disk has no media. 26: Formatting - In the process of formatting. 28: Diagnostics - Diagnostics are running. 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers.

Source records

arrayDiskState

Status in source: mandatory.

Names: arrayDiskState

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "arrayDiskState",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "ready",
    "(",
    "1",
    ")",
    ",",
    "failed",
    "(",
    "2",
    ")",
    ",",
    "online",
    "(",
    "3",
    ")",
    ",",
    "offline",
    "(",
    "4",
    ")",
    ",",
    "degraded",
    "(",
    "6",
    ")",
    ",",
    "recovering",
    "(",
    "7",
    ")",
    ",",
    "removed",
    "(",
    "11",
    ")",
    ",",
    "resynching",
    "(",
    "15",
    ")",
    ",",
    "rebuild",
    "(",
    "24",
    ")",
    ",",
    "noMedia",
    "(",
    "25",
    ")",
    ",",
    "formatting",
    "(",
    "26",
    ")",
    ",",
    "diagnostics",
    "(",
    "28",
    ")",
    ",",
    "initializing",
    "(",
    "35",
    ")",
    "}",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller. 6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk. 7: Recovering - Refers to state of recovering from bad blocks on disks. 11: Removed - Indicates that array disk has been removed. 15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency. 24: Rebuild 25: No Media - CD-ROM or removable disk has no media. 26: Formatting - In the process of formatting. 28: Diagnostics - Diagnostics are running. 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers. \"",
    "::=",
    "{",
    "arrayDiskEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "ready",
            1
          ],
          [
            "failed",
            2
          ],
          [
            "online",
            3
          ],
          [
            "offline",
            4
          ],
          [
            "degraded",
            6
          ],
          [
            "recovering",
            7
          ],
          [
            "removed",
            11
          ],
          [
            "resynching",
            15
          ],
          [
            "rebuild",
            24
          ],
          [
            "noMedia",
            25
          ],
          [
            "formatting",
            26
          ],
          [
            "diagnostics",
            28
          ],
          [
            "initializing",
            35
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller. 6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk. 7: Recovering - Refers to state of recovering from bad blocks on disks. 11: Removed - Indicates that array disk has been removed. 15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency. 24: Rebuild 25: No Media - CD-ROM or removable disk has no media. 26: Formatting - In the process of formatting. 28: Diagnostics - Diagnostics are running. 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers."
    ],
    null,
    null,
    null,
    null
  ]
}
  • Preserved mibdepot archive

    Module: ArrayManager-MIB

    Published definition
    arrayDiskState OBJECT-TYPE
    			SYNTAX INTEGER
    				{
    				ready(1),
    				failed(2),
    				online(3),
    				offline(4),
    				degraded(6),
    				recovering(7),
    				removed(11),
    				resynching(15),
    				rebuild(24),
    				noMedia(25),
    				formatting(26),
    				diagnostics(28),
    				initializing(35)
    				}
    			ACCESS read-only
    			STATUS mandatory
    			DESCRIPTION
    				"The current state of the array disk.
    				Possible states:
    				 0: Unknown
    				 1: Ready - Available for use, but no RAID configuration has been assigned. 
    				 2: Failed - Not operational.
    				 3: Online - Operational. RAID configuration has been assigned.
    				 4: Offline - The drive is not available to the RAID controller. 
    				 6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk. 
    				 7: Recovering - Refers to state of recovering from bad blocks on disks. 
    				11: Removed - Indicates that array disk has been removed. 
    				15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency. 
    				24: Rebuild
    				25: No Media - CD-ROM or removable disk has no media. 
    				26: Formatting - In the process of formatting. 
    				28: Diagnostics - Diagnostics are running. 
    				35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers. 
    				"
    			::= { arrayDiskEntry 4 }
    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Archived source file
    Source location: ArrayManager-MIB::arrayDiskState.
    Source version and references

    Archived: 2026-10-19T00:22:08.871836+00:00.

Information from OID Repository

Vendor: Dell
Module: ArrayManager-MIB (arymgr.mib)
Type: TABULAR
Access: read-only
Syntax: INTEGER

Automatically extracted from www.mibdepot.com

Information from MIBdepot

arrayDiskState OBJECT-TYPE
			SYNTAX INTEGER
				{
				ready(1),
				failed(2),
				online(3),
				offline(4),
				degraded(6),
				recovering(7),
				removed(11),
				resynching(15),
				rebuild(24),
				noMedia(25),
				formatting(26),
				diagnostics(28),
				initializing(35)
				}
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"The current state of the array disk.
				Possible states:
				 0: Unknown
				 1: Ready - Operational. 
				 2: Failed - Not operational.
				 3: Online - Operational. 
				 4: Offline - The drive is not available to the RAID controller. 
				 6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk. 
				 7: Recovering - Refers to state of recovering from bad blocks on disks. 
				11: Removed - Indicates that array disk has been removed. 
				15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency. 
				24: Rebuild
				25: No Media - CD-ROM or removable disk has no media. 
				26: Formatting - In the process of formatting. 
				28: Diagnostics - Diagnostics are running. 
				35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers. 
				"
			::= { arrayDiskEntry 4 }

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.674)

Wood Eric

Siblings (21)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.674.10893.1.1.130.4.1.1 arrayDiskNumber00 Instance number of this array disk entry.
1.3.6.1.4.1.674.10893.1.1.130.4.1.2 arrayDiskName00 The name of the array disk as represented in Array Manager.
1.3.6.1.4.1.674.10893.1.1.130.4.1.3 arrayDiskVendor00 The array disk's (re)seller's name.
1.3.6.1.4.1.674.10893.1.1.130.4.1.5 arrayDiskSeverity00 Severity of the array disk state.
Possible values:
0: OK
1: Warning
2: Error
3: Failure
1.3.6.1.4.1.674.10893.1.1.130.4.1.6 arrayDiskProductID00 The model number of the array disk.
1.3.6.1.4.1.674.10893.1.1.130.4.1.7 arrayDiskSerialNo00 The array disk's unique identification number from the manufacturer.
1.3.6.1.4.1.674.10893.1.1.130.4.1.8 arrayDiskRevision00 The firmware version of the array disk.
1.3.6.1.4.1.674.10893.1.1.130.4.1.9 arrayDiskEnclosureID00 The SCSI ID of the enclosure processor to which this array disk belongs.
1.3.6.1.4.1.674.10893.1.1.130.4.1.10 arrayDiskChannel00 The bus to which this array disk is connected.
1.3.6.1.4.1.674.10893.1.1.130.4.1.11 arrayDiskLengthInMB00 The size in megabytes of the array disk. If this size
is 0, it is smaller than a megabyte.
1.3.6.1.4.1.674.10893.1.1.130.4.1.12 arrayDiskLengthInBytes00 The size of the array disk in bytes that is less than
a megabyte. This size plus the arrayDiskLengthInMB is
the total size of th…
1.3.6.1.4.1.674.10893.1.1.130.4.1.13 arrayDiskLargestContiguousFreeSpaceInMB00 The size in megabytes of the largest contiguous free space
on the array disk. If this size is 0, it is less than a
megabyte.
1.3.6.1.4.1.674.10893.1.1.130.4.1.14 arrayDiskLargestContiguousFreeSpaceInBytes00 The size of the largest contiguouis free space on this
array disk in bytes that is less than a megabyte.
This size plus the array…
1.3.6.1.4.1.674.10893.1.1.130.4.1.15 arrayDiskTargetID00 The SCSI target ID which this array disk occupies.
This is the slot number.
1.3.6.1.4.1.674.10893.1.1.130.4.1.16 arrayDiskLunID00 The array disk's logical unit number.
1.3.6.1.4.1.674.10893.1.1.130.4.1.17 arrayDiskUsedSpaceInMB00 The amount in megabytes of the used space on the array
disk. If this size is 0, it is smaller than a megabyte.
1.3.6.1.4.1.674.10893.1.1.130.4.1.18 arrayDiskUsedSpaceInBytes00 The size in bytes of the used space on the array disk
that is smaller than a megabyte. This size plus the
arrayDiskUsedSpaceInMB…
1.3.6.1.4.1.674.10893.1.1.130.4.1.19 arrayDiskFreeSpaceInMB00 The amount in megabytes of the free space on the array
disk. If this size is 0, it is smaller than a megabyte.
1.3.6.1.4.1.674.10893.1.1.130.4.1.20 arrayDiskFreeSpaceInBytes00 The size in bytes of the free space on the array disk
that is smaller than a megabyte. This size plus the
arrayDiskFreeSpaceInMB…
1.3.6.1.4.1.674.10893.1.1.130.4.1.21 arrayDiskBusType00 The bus type of the array disk.
Possible values:
1: SCSI
2: IDE
3: Fibre Channel
4: SSA
6: USB
1.3.6.1.4.1.674.10893.1.1.130.4.1.22 arrayDiskSpareState00 The status of the array disk as a spare.
Possible states:
1: disk is a member of a virtual disk
2: disk is a member of a disk grou…