The current state of the array disk.
Possible states:
0: Unknown
1: Ready - Operational.
2: Failed - Not operational.
3: Online - Operational.
4: Offline - The drive is not available to the RAID controller.
6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk.
7: Recovering - Refers to state of recovering from bad blocks on disks.
11: Removed - Indicates that array disk has been removed.
15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency.
24: Rebuild
25: No Media - CD-ROM or removable disk has no media.
26: Formatting - In the process of formatting.
28: Diagnostics - Diagnostics are running.
35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers.
Parsed from file arymgr.mib.txt
Company: dell
Module: ArrayManager-MIB
Vendor: Dell
Module: ArrayManager-MIB (arymgr.mib)
Type: TABULAR
Access: read-only
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
arrayDiskState OBJECT-TYPE SYNTAX INTEGER { ready(1), failed(2), online(3), offline(4), degraded(6), recovering(7), removed(11), resynching(15), rebuild(24), noMedia(25), formatting(26), diagnostics(28), initializing(35) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the array disk. Possible states: 0: Unknown 1: Ready - Operational. 2: Failed - Not operational. 3: Online - Operational. 4: Offline - The drive is not available to the RAID controller. 6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk. 7: Recovering - Refers to state of recovering from bad blocks on disks. 11: Removed - Indicates that array disk has been removed. 15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency. 24: Rebuild 25: No Media - CD-ROM or removable disk has no media. 26: Formatting - In the process of formatting. 28: Diagnostics - Diagnostics are running. 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers. " ::= { arrayDiskEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.674.10893.1.1.130.4.1.1 | arrayDiskNumber | 0 | 0 | Instance number of this array disk entry. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.2 | arrayDiskName | 0 | 0 | The name of the array disk as represented in Array Manager. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.3 | arrayDiskVendor | 0 | 0 | The array disk's (re)seller's name. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.5 | arrayDiskSeverity | 0 | 0 | Severity of the array disk state. Possible values: 0: OK 1: Warning 2: Error 3: Failure |
1.3.6.1.4.1.674.10893.1.1.130.4.1.6 | arrayDiskProductID | 0 | 0 | The model number of the array disk. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.7 | arrayDiskSerialNo | 0 | 0 | The array disk's unique identification number from the manufacturer. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.8 | arrayDiskRevision | 0 | 0 | The firmware version of the array disk. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.9 | arrayDiskEnclosureID | 0 | 0 | The SCSI ID of the enclosure processor to which this array disk belongs. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.10 | arrayDiskChannel | 0 | 0 | The bus to which this array disk is connected. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.11 | arrayDiskLengthInMB | 0 | 0 | The size in megabytes of the array disk. If this size is 0, it is smaller than a megabyte. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.12 | arrayDiskLengthInBytes | 0 | 0 | The size of the array disk in bytes that is less than a megabyte. This size plus the arrayDiskLengthInMB is the total size of th… |
1.3.6.1.4.1.674.10893.1.1.130.4.1.13 | arrayDiskLargestContiguousFreeSpaceInMB | 0 | 0 | The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.14 | arrayDiskLargestContiguousFreeSpaceInBytes | 0 | 0 | The size of the largest contiguouis free space on this array disk in bytes that is less than a megabyte. This size plus the array… |
1.3.6.1.4.1.674.10893.1.1.130.4.1.15 | arrayDiskTargetID | 0 | 0 | The SCSI target ID which this array disk occupies. This is the slot number. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.16 | arrayDiskLunID | 0 | 0 | The array disk's logical unit number. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.17 | arrayDiskUsedSpaceInMB | 0 | 0 | The amount in megabytes of the used space on the array disk. If this size is 0, it is smaller than a megabyte. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.18 | arrayDiskUsedSpaceInBytes | 0 | 0 | The size in bytes of the used space on the array disk that is smaller than a megabyte. This size plus the arrayDiskUsedSpaceInMB… |
1.3.6.1.4.1.674.10893.1.1.130.4.1.19 | arrayDiskFreeSpaceInMB | 0 | 0 | The amount in megabytes of the free space on the array disk. If this size is 0, it is smaller than a megabyte. |
1.3.6.1.4.1.674.10893.1.1.130.4.1.20 | arrayDiskFreeSpaceInBytes | 0 | 0 | The size in bytes of the free space on the array disk that is smaller than a megabyte. This size plus the arrayDiskFreeSpaceInMB… |
1.3.6.1.4.1.674.10893.1.1.130.4.1.21 | arrayDiskBusType | 0 | 0 | The bus type of the array disk. Possible values: 1: SCSI 2: IDE 3: Fibre Channel 4: SSA 6: USB |
1.3.6.1.4.1.674.10893.1.1.130.4.1.22 | arrayDiskSpareState | 0 | 0 | The status of the array disk as a spare. Possible states: 1: disk is a member of a virtual disk 2: disk is a member of a disk grou… |