Sets the VINES Routing selection.
Automatic - Utilizes Sequenced Routing if available,
otherwise uses Non-Sequenced Routing.
Force-Sequenced - Will only use Sequenced Routing.
Force-Non-Sequenced - Will only use Non-Sequenced Routing
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.
WARNING - Sequential Routing requires a VINES 5.5 or
greater server on the same subnet.
Parsed from file ESI.MIB.txt
Company: None
Module: ESI-MIB
Sets the VINES Routing selection.
Automatic - Utilizes Sequenced Routing if available,
otherwise uses Non-Sequenced Routing.
Force-Sequenced - Will only use Sequenced Routing.
Force-Non-Sequenced - Will only use Non-Sequenced Routing
In order for changes to this variable to take effect,
the print server must be reset. See cmdReset to do
this.
WARNING - Sequential Routing requires a VINES 5.5 or
greater server on the same subnet.
Parsed from file ESI-MIB.mib
Module: ESI-MIB
Vendor: Extended Systems, Inc.
Module: ESI-MIB
[Automatically extracted from oidview.com]
bvSetSequenceRouting OBJECT-TYPE SYNTAX INTEGER { automatic-Routing(1), force-Sequenced-Routing(2), force-Non-Sequenced-Routing(3) } ACCESS read-write STATUS optional DESCRIPTION "Sets the VINES Routing selection. Automatic - Utilizes Sequenced Routing if available, otherwise uses Non-Sequenced Routing. Force-Sequenced - Will only use Sequenced Routing. Force-Non-Sequenced - Will only use Non-Sequenced Routing In order for changes to this variable to take effect, the print server must be reset. See cmdReset to do this. WARNING - Sequential Routing requires a VINES 5.5 or greater server on the same subnet." ::= { bvCommands 3 }
bvSetSequenceRouting OBJECT-TYPE SYNTAX INTEGER { automatic-Routing(1), force-Sequenced-Routing(2), force-Non-Sequenced-Routing(3) } ACCESS read-write STATUS optional DESCRIPTION "Sets the VINES Routing selection. Automatic - Utilizes Sequenced Routing if available, otherwise uses Non-Sequenced Routing. Force-Sequenced - Will only use Sequenced Routing. Force-Non-Sequenced - Will only use Non-Sequenced Routing In order for changes to this variable to take effect, the print server must be reset. See cmdReset to do this. WARNING - Sequential Routing requires a VINES 5.5 or greater server on the same subnet." ::= { bvCommands 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.683.6.3.3.3.3.0 | bvSetSequenceRouting | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.683.6.3.3.3.1 | bvRestoreDefaults | 1 | 1 | A value of 2 will restore all VINES parameters on the print server to factory defaults, as well as reset the device. |
1.3.6.1.4.1.683.6.3.3.3.2 | bvFirmwareUpgrade | 1 | 1 | A value of 2 will put the print server into firmware upgrade mode. |
1.3.6.1.4.1.683.6.3.3.3.4 | bvDisableVPMan | 1 | 1 | A value of 2 will disable VPMan access to the print server for one minute. |