This is the ifIndex value of the corresponding
ifEntry. See comments above.
This is the ifIndex value of the corresponding
ifEntry. See comments above.
Parsed from file LS2020-R2-MIB.my.txt
Company: None
Module: LIGHTSTREAM-MIB
This is the ifIndex value of the corresponding
ifEntry. See comments above.
Parsed from file LIGHTSTREAM-MIB.mib
Module: LIGHTSTREAM-MIB
ms1InfoIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the ifIndex value of the corresponding ifEntry. See comments above." ::= { ms1InfoEntry 1 }
Vendor: Cisco Systems
Module: LIGHTSTREAM-MIB (LS2020-R2-MIB.my)
Type: TABULAR
Access: read-only
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
ms1InfoIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the ifIndex value of the corresponding ifEntry. See comments above." ::= { ms1InfoEntry 1 }
ms1InfoIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the ifIndex value of the corresponding ifEntry. See comments above." ::= { ms1InfoEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.711.2.1.4.2.1.2 | ms1InfoOperCableLength | 0 | 0 | Operational value for Cable Length used for this port. |
1.3.6.1.4.1.711.2.1.4.2.1.3 | ms1InfoAdminCableLength | 0 | 0 | Administrative value for Cable Length used for this port. Setting the trigger variable ms1InfoAdimOperTrigger will cause this va… |
1.3.6.1.4.1.711.2.1.4.2.1.4 | ms1InfoOperProtocol | 0 | 0 | Operational higher level protocol stack to support on this port. |
1.3.6.1.4.1.711.2.1.4.2.1.5 | ms1InfoAdminProtocol | 0 | 0 | Administratively desired higher level protocol stack to support on this port. |
1.3.6.1.4.1.711.2.1.4.2.1.10 | ms1InfoOperControlBandwidthSize | 0 | 0 | The current operation value of the control bandwidth size for this port. This is a scaling factor. This value is multiplied by … |
1.3.6.1.4.1.711.2.1.4.2.1.11 | ms1InfoAdminControlBandwidthSize | 0 | 0 | The current administratively desired value of the control bandwidth size for this port. Setting the trigger variable ms1InfoAdimO… |
1.3.6.1.4.1.711.2.1.4.2.1.12 | ms1InfoOperDataBandwidthSize | 0 | 0 | The current operation value of the data bandwidth size for this port. This is a scaling factor. This value is multiplied by ms1… |
1.3.6.1.4.1.711.2.1.4.2.1.13 | ms1InfoAdminDataBandwidthSize | 0 | 0 | The current administratively desired value of the data bandwidth size for this port. Setting the trigger variable ms1InfoAdimOper… |
1.3.6.1.4.1.711.2.1.4.2.1.14 | ms1InfoLcAutoEnable | 0 | 0 | State of the LC auto-enable flag for this port. If enabled the port will be enable at LC boot time. If disabled the port will re… |
1.3.6.1.4.1.711.2.1.4.2.1.15 | ms1InfoLcDebugLevel | 0 | 0 | Value of the LC debug level variable for this port. This parameter is set in the LC EEPROM by portctl. |
1.3.6.1.4.1.711.2.1.4.2.1.16 | ms1InfoOperScramble | 0 | 0 | Operational value for Cell Payload scrambling used for this port. |
1.3.6.1.4.1.711.2.1.4.2.1.17 | ms1InfoAdminScramble | 0 | 0 | Administrative value for Cell Payload scrambling used for this port. Setting the trigger variable ms1InfoAdimOperTrigger will ca… |
1.3.6.1.4.1.711.2.1.4.2.1.18 | ms1InfoDataCellCapacity | 0 | 0 | The portion of this port's capacity in cells that is allocated for data traffic. |
1.3.6.1.4.1.711.2.1.4.2.1.19 | ms1InfoDataCellAvailable | 0 | 0 | The portion of this port's capacity in cells that is available for data traffic. This variable is adjusted for the bandwidth con… |
1.3.6.1.4.1.711.2.1.4.2.1.20 | ms1InfoLinkUtilization | 0 | 0 | This is an estimated utilization on the link. |
1.3.6.1.4.1.711.2.1.4.2.1.21 | ms1InfoOperFraming | 0 | 0 | Operational ATM framing typein use on this port. |
1.3.6.1.4.1.711.2.1.4.2.1.99 | ms1InfoAdminOperTrigger | 0 | 0 | When proper commands written to this variable the LCC attempts to change the state of the port such that the oper status reflects… |