The counter associated with the number of
frames that were discarded due to exceeding the
maximum throughput configured for the PVC (the
Committed Burst Size plus the Excess Burst Size).
If the Committed Information Rate (CIR) has not
been configured for the PVC, then this field is
not applicable.
Parsed from file att_efr.mib.txt
Company: None
Module: ATT-CNM-ENHANCED-FRAME-RELAY-MIB
The counter associated with the number of
frames that were discarded due to exceeding the
maximum throughput configured for the PVC (the
Committed Burst Size plus the Excess Burst Size).
If the Committed Information Rate (CIR) has not
been configured for the PVC, then this field is
not applicable.
Parsed from file ATT-CNM-ENHANCED-FRAME-RELAY-MIB.mib
Module: ATT-CNM-ENHANCED-FRAME-RELAY-MIB
Vendor: AT&T
Module: ATT-CNM-ENHANCED-FRAME-RELAY-MIB
[Automatically extracted from oidview.com]
attCNMefrBurstSizeExceeded OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of frames that were discarded due to exceeding the maximum throughput configured for the PVC (the Committed Burst Size plus the Excess Burst Size). If the Committed Information Rate (CIR) has not been configured for the PVC, then this field is not applicable." ::= { attCNMefrPVCMeasEntry 9 }
attCNMefrBurstSizeExceeded OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of frames that were discarded due to exceeding the maximum throughput configured for the PVC (the Committed Burst Size plus the Excess Burst Size). If the Committed Information Rate (CIR) has not been configured for the PVC, then this field is not applicable." ::= { attCNMefrPVCMeasEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.74.2.15.8.4.1.1 | attCNMefrPVCMeasIfIndex | 0 | 0 | A unique value for each Frame Relay interface. The interface identified by a particular value of this index is the same interface… |
1.3.6.1.4.1.74.2.15.8.4.1.2 | attCNMefrPVCMeasIndex | 0 | 0 | The DLCI number on a Frame Relay interface that identifies a unique Data Link Connection. |
1.3.6.1.4.1.74.2.15.8.4.1.3 | attCNMefrPVCMeasInterval | 0 | 0 | This variable identifies the measurement interval number for which measurement is provided. It is a number between 1 and XX, wher… |
1.3.6.1.4.1.74.2.15.8.4.1.4 | attCNMefrPVCMeasTimeStamp | 0 | 0 | The time stamp corresponding to the end of the specified measurement interval, as measured in seconds from 00:00:00 UTC (Coordina… |
1.3.6.1.4.1.74.2.15.8.4.1.5 | attCNMefrPVCMeasLocalTime | 0 | 0 | The time stamp corresponding to the end of the specified measurement interval. Any fraction is rounded up. It is given as a prin… |
1.3.6.1.4.1.74.2.15.8.4.1.6 | attCNMefrPVCReceivedFrames | 0 | 0 | The counter associated with the number of frames received by this Frame Relay PVC during the specified measurement interval. |
1.3.6.1.4.1.74.2.15.8.4.1.7 | attCNMefrPVCSentFrames | 0 | 0 | The counter associated with the number of frames sent by this Frame Relay PVC during the specified measurement interval. |
1.3.6.1.4.1.74.2.15.8.4.1.8 | attCNMefrDiscardEligibilityFrames | 0 | 0 | The counter associated with the number of ingress frames received by this PVC that exceed the Committed Burst Size but don't exce… |
1.3.6.1.4.1.74.2.15.8.4.1.10 | attCNMefrCongestionAtIngress | 0 | 0 | The counter associated with the number of times frames received by this PVC had to be discarded because buffers were unavailable … |
1.3.6.1.4.1.74.2.15.8.4.1.11 | attCNMefrCongestionAtEgress | 0 | 0 | The counter associated with the number of times frames sent by this PVC had to be discarded because buffers were unavailable or c… |