In the case when reconstruction/adding a
spare, verification or scrubbing is in progress,
the percent of such reconstruction, verification
or scrubbing that has been completed on the
referenced disk drive.
Parsed from file netapp_1_4.mib.txt
Company: None
Module: NETWORK-APPLIANCE-MIB
In the case when reconstruction/adding a
spare, verification or scrubbing is in progress,
the percent of such reconstruction, verification
or scrubbing that has been completed on the
referenced disk drive.
Parsed from file NETWORK-APPLIANCE-MIB.mib
Module: NETWORK-APPLIANCE-MIB
Vendor: Network Appliance Corporation
Module: NETWORK-APPLIANCE-MIB
[Automatically extracted from oidview.com]
raidCompletionPerCent OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS deprecated DESCRIPTION "In the case when reconstruction/adding a spare, verification or scrubbing is in progress, the percent of such reconstruction, verification or scrubbing that has been completed on the referenced disk drive." ::= { raidEntry 11 }
raidCompletionPerCent OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "In the case when reconstruction/adding a spare, verification or scrubbing is in progress, the percent of such reconstruction, verification or scrubbing that has been completed on the referenced disk drive." ::= { raidEntry 11 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.789.1.6.1.1.1 | raidIndex | 0 | 0 | A number that identifies this entry for the referenced disk drive. |
1.3.6.1.4.1.789.1.6.1.1.2 | raidDiskName | 0 | 0 | The name identifying the referenced disk drive. |
1.3.6.1.4.1.789.1.6.1.1.3 | raidStatus | 0 | 0 | The status of the referenced disk drive. |
1.3.6.1.4.1.789.1.6.1.1.4 | raidDiskId | 0 | 0 | The disk identifier for the referenced disk drive. |
1.3.6.1.4.1.789.1.6.1.1.5 | raidScsiAdapter | 0 | 0 | The identifier of the SCSI adapter for the referenced disk drive. |
1.3.6.1.4.1.789.1.6.1.1.6 | raidScsiId | 0 | 0 | The identifier for the referenced disk drive on the referenced SCSI adapter. |
1.3.6.1.4.1.789.1.6.1.1.7 | raidUsedMb | 0 | 0 | The number of MBytes currently in use on the referenced disk drive. |
1.3.6.1.4.1.789.1.6.1.1.8 | raidUsedBlocks | 0 | 0 | The number of Blocks currently in use on the referenced disk drive. |
1.3.6.1.4.1.789.1.6.1.1.9 | raidTotalMb | 0 | 0 | The number of MBytes physically available on the referenced disk drive. |
1.3.6.1.4.1.789.1.6.1.1.10 | raidTotalBlocks | 0 | 0 | The number of Blocks physically available on the referenced disk drive. |