Vendor: Network Appliance Corporation
Module: NETWORK-APPLIANCE-MIB
[Automatically extracted from oidview.com]
diskSummary OBJECT IDENTIFIER ::= { raid 4 }
diskSummary OBJECT IDENTIFIER ::= { raid 4 }
| OID | Name | Sub children | Sub Nodes Total | Description | 
|---|---|---|---|---|
| 1.3.6.1.4.1.789.1.6.4.1 | diskTotalCount | 1 | 1 | The total number of disks on the system. | 
| 1.3.6.1.4.1.789.1.6.4.2 | diskActiveCount | 1 | 1 | The number of disks which are currently active, including parity disks.  | 
            
| 1.3.6.1.4.1.789.1.6.4.3 | diskReconstructingCount | 1 | 1 | The number of disks which are currently being reconstructed.  | 
            
| 1.3.6.1.4.1.789.1.6.4.4 | diskReconstructingParityCount | 1 | 1 | The number of parity disks which are currently being reconstructed.  | 
            
| 1.3.6.1.4.1.789.1.6.4.5 | diskVerifyingParityCount | 1 | 1 | The number of parity disks which are currently being verified.  | 
            
| 1.3.6.1.4.1.789.1.6.4.6 | diskScrubbingCount | 1 | 1 | The number of disks which are currently being scrubbed.  | 
            
| 1.3.6.1.4.1.789.1.6.4.7 | diskFailedCount | 1 | 1 | The number of disks which are currently broken.  | 
            
| 1.3.6.1.4.1.789.1.6.4.8 | diskSpareCount | 1 | 1 | The number of available spare disks. | 
| 1.3.6.1.4.1.789.1.6.4.9 | diskAddingSpareCount | 1 | 1 | The number of spare disks which are currently being added into a RAID group.  | 
            
| 1.3.6.1.4.1.789.1.6.4.10 | diskFailedMessage | 1 | 1 | If diskFailedCount is non-zero, this is a string describing the failed disk or disks. Each failed disk is described with a senten…  | 
            
| 1.3.6.1.4.1.789.1.6.4.11 | diskPrefailedCount | 1 | 1 | The number of disks which are prefailed and marked for rapid raid recovery.  | 
            
| OID | Name | Sub children | Sub Nodes Total | Description | 
|---|---|---|---|---|
| 1.3.6.1.4.1.789.1.6.1 | raidTable | 1 | 12 | Display RAID configuration information for the root volume. This table is deprecated - use raidVTable instead.  | 
        
| 1.3.6.1.4.1.789.1.6.2 | raidVTable | 1 | 38 | Display RAID configuration information. | 
| 1.3.6.1.4.1.789.1.6.3 | spareTable | 1 | 25 | Display spare disk configuration information. | 
| 1.3.6.1.4.1.789.1.6.5 | raidVNumber | 1 | 1 | Number of entries in the raidVTable table. This is the number of volumes in the system.  | 
        
| 1.3.6.1.4.1.789.1.6.6 | spareNumber | 1 | 1 | Number of entries in the spareTable table. | 
| 1.3.6.1.4.1.789.1.6.7 | otherDiskNumber | 1 | 1 | Number of entries in the otherDiskTable table. | 
| 1.3.6.1.4.1.789.1.6.8 | raidPNumber | 1 | 1 | Number of entries in the raidPTable table. This is the number of volumes in the system.  | 
        
| 1.3.6.1.4.1.789.1.6.9 | otherDiskTable | 1 | 24 | Display out-of-service disk configuration information. | 
| 1.3.6.1.4.1.789.1.6.10 | raidPTable | 1 | 36 | Display RAID configuration information. | 
| 1.3.6.1.4.1.789.1.6.11 | plexTable | 1 | 6 | A table containing plex specific information. | 
| 1.3.6.1.4.1.789.1.6.12 | outOfDateDiskCount | 1 | 1 | Number of entries in the outOfDateDiskTable table. | 
| 1.3.6.1.4.1.789.1.6.13 | outOfDateDiskTable | 1 | 23 | Display out-of-date disk information. |