A controller entry containing objects for a particular
controller.
Parsed from file xylan-chassis.mib.txt
Company: None
Module: CHASSIS-MIB
A controller entry containing objects for a particular
controller.
Parsed from file CHASSIS-MIB.mib
Module: CHASSIS-MIB
Vendor: Enterasys Networks Inc.
Module: CHASSIS-MIB
[Automatically extracted from oidview.com]
chasControlEntry OBJECT-TYPE SYNTAX ChasControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A controller entry containing objects for a particular controller." INDEX { chasControlSlot } ::= { chasControlTable 1 }
chasControlEntry OBJECT-TYPE SYNTAX ChasControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A controller entry containing objects for a particular controller." INDEX { chasControlSlot } ::= { chasControlTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.800.2.1.3.1.1.1 | chasControlSlot | 0 | 0 | The physical slot number for this controller card. This is the same as chasModuleSlot. |
1.3.6.1.4.1.800.2.1.3.1.1.2 | chasControlState | 0 | 0 | Provides desired (and actual) state of the given controller module. The unknown state may be returned if the controller is not pr… |
1.3.6.1.4.1.800.2.1.3.1.1.3 | chasControlDCEPortRate | 0 | 0 | This is the current (and desired) baud rate for the DCE (console) serial port 1. The power-on default rate is 9600 b/s. |
1.3.6.1.4.1.800.2.1.3.1.1.4 | chasControlDCEWordSize | 0 | 0 | This is the current (and desired) word size for serial port 0 (DCE). The power-on default is 8 bits. |
1.3.6.1.4.1.800.2.1.3.1.1.5 | chasControlDCEStopBits | 0 | 0 | This is the current (and desired) number of stop bits for serial port 0 (DCE). The power-on default is 1 bit. |
1.3.6.1.4.1.800.2.1.3.1.1.6 | chasControlDCEParity | 0 | 0 | This is the current (and desired) parity for serial port 0 (DCE). The power-on default rate is NONE. |
1.3.6.1.4.1.800.2.1.3.1.1.7 | chasControlDTEPortRate | 0 | 0 | This is the current (and desired) baud rate for the DTE (modem) serial port 0. The power-on default rate is 9600 b/s. |
1.3.6.1.4.1.800.2.1.3.1.1.8 | chasControlDTEWordSize | 0 | 0 | This is the current (and desired) word size for serial port 1 (DTE). The power-on default is 8 bits. |
1.3.6.1.4.1.800.2.1.3.1.1.9 | chasControlDTEStopBits | 0 | 0 | This is the current (and desired) number of stop bits for serial port 1 (DTE). The power-on default is 1 bit. |
1.3.6.1.4.1.800.2.1.3.1.1.10 | chasControlDTEParity | 0 | 0 | This is the current (and desired) parity for serial port 1 (DTE). The power-on default rate is NONE. |
1.3.6.1.4.1.800.2.1.3.1.1.11 | chasControlIPAdd | 0 | 0 | The IP address for this MPM and it's snmp agent. |
1.3.6.1.4.1.800.2.1.3.1.1.12 | chasControlBootCode | 0 | 0 | FW boot code to load on reset for this controller. |
1.3.6.1.4.1.800.2.1.3.1.1.13 | chasControlFreeFFS | 0 | 0 | The current free Flash File System space. |
1.3.6.1.4.1.800.2.1.3.1.1.14 | chasControlFreeBuffers | 0 | 0 | The current software does not pool a specific number of buffers. Therefore this object is obsolete. |
1.3.6.1.4.1.800.2.1.3.1.1.15 | chasControlBufferUtilization | 0 | 0 | The current software does not pool a specific number of buffers. Therefore this object is obsolete. |
1.3.6.1.4.1.800.2.1.3.1.1.16 | chasControlCPUUtilization | 0 | 0 | The current CPU utilization for this controller. |
1.3.6.1.4.1.800.2.1.3.1.1.17 | chasControlImageSuffix | 0 | 0 | This character string will be used to determine which file is downloaded to the NIs to be brought up by the chassis manager. Onl… |
1.3.6.1.4.1.800.2.1.3.1.1.18 | chasControlImageSyncStatus | 0 | 0 | For the Primary this means: insync(1) the files in the secondary's flash file system are the same as those in the primary's. newer… |
1.3.6.1.4.1.800.2.1.3.1.1.19 | chasControlConfigSyncStatus | 0 | 0 | insync(1) All configuration data on the Primary is the same as that on the secondary. newer(2) The config data on the Primary MP… |
1.3.6.1.4.1.800.2.1.3.1.1.20 | chasControlConfigSyncEnable | 0 | 0 | enabled(1) - After changes to configuration data AND after 5 min from the last change if the image files are synced, sync synchron… |
1.3.6.1.4.1.800.2.1.3.1.1.21 | chasControlDCEPortMode | 0 | 0 | down(1) - This port is down. console(2) - This is the console port slip(3) - This is a slip port. This value can only be … |
1.3.6.1.4.1.800.2.1.3.1.1.22 | chasControlDTEPortMode | 0 | 0 | down(1) - This port is down. console(2) - This is the console port slip(3) - This is a slip port. This value can only be … |
1.3.6.1.4.1.800.2.1.3.1.1.23 | chasControlEthPortIPAddr | 0 | 0 | The IP network address of the Ethernet Mgmt. Port. |
1.3.6.1.4.1.800.2.1.3.1.1.24 | chasControlEthPortSubMask | 0 | 0 | The IP network subnet mask of the Ethernet Mgmt. Port. |
1.3.6.1.4.1.800.2.1.3.1.1.25 | chasControlEthPortBcast | 0 | 0 | The IP network broadcast address of the Ethernet Mgmt. Port. |
1.3.6.1.4.1.800.2.1.3.1.1.26 | chasControlEthPortGateWay | 0 | 0 | The IP network gateway address of the Ethernet Mgmt. Port. |
1.3.6.1.4.1.800.2.1.3.1.1.27 | chasControlEthPortRipMode | 0 | 0 | The RIP mode of the Ethernet Mgmt. Port. |
1.3.6.1.4.1.800.2.1.3.1.1.28 | chasControlEthPortRemoteHost | 0 | 0 | The IP network remote host address of the Ethernet Mgmt. Port. |
1.3.6.1.4.1.800.2.1.3.1.1.29 | chasControlEthPortRemoteMask | 0 | 0 | The IP network remote host subnet mask of the Ethernet Mgmt. Port. |