Reference record for OID 1.3.6.1.4.1.800.2.4.10.1.4.1.1.11



parent
1.3.6.1.4.1.800.2.4.10.1.4.1.1 (atmxCesSvcConfigEntry)
node code
11
node name
atmxCesSvcConfigRestart
dot oid
1.3.6.1.4.1.800.2.4.10.1.4.1.1.11
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) xylan(800) xylanArch(2) xylanAtmArch(4) atmxCesGroup(10) atmxCesMIBObjects(1) atmxCesSvcConfigGroup(4) atmxCesSvcConfigTable(1) atmxCesSvcConfigEntry(1) atmxCesSvcConfigRestart(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) xylan(800) xylanArch(2) xylanAtmArch(4) atmxCesGroup(10) atmxCesMIBObjects(1) atmxCesSvcConfigGroup(4) atmxCesSvcConfigTable(1) atmxCesSvcConfigEntry(1) atmxCesSvcConfigRestart(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) xylan(800) xylanArch(2) xylanAtmArch(4) atmxCesGroup(10) atmxCesMIBObjects(1) atmxCesSvcConfigGroup(4) atmxCesSvcConfigTable(1) atmxCesSvcConfigEntry(1) atmxCesSvcConfigRestart(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) xylan(800) xylanArch(2) xylanAtmArch(4) atmxCesGroup(10) atmxCesMIBObjects(1) atmxCesSvcConfigGroup(4) atmxCesSvcConfigTable(1) atmxCesSvcConfigEntry(1) atmxCesSvcConfigRestart(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) xylan(800) xylanArch(2) xylanAtmArch(4) atmxCesGroup(10) atmxCesMIBObjects(1) atmxCesSvcConfigGroup(4) atmxCesSvcConfigTable(1) atmxCesSvcConfigEntry(1) atmxCesSvcConfigRestart(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) xylan(800) xylanArch(2) xylanAtmArch(4) atmxCesGroup(10) atmxCesMIBObjects(1) atmxCesSvcConfigGroup(4) atmxCesSvcConfigTable(1) atmxCesSvcConfigEntry(1) atmxCesSvcConfigRestart(11)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/xylan/xylanArch/xylanAtmArch/atmxCesGroup/atmxCesMIBObjects/atmxCesSvcConfigGroup/atmxCesSvcConfigTable/atmxCesSvcConfigEntry/atmxCesSvcConfigRestart
  • /iso/identified-organization/dod/internet/private/enterprises/xylan/xylanArch/xylanAtmArch/atmxCesGroup/atmxCesMIBObjects/atmxCesSvcConfigGroup/atmxCesSvcConfigTable/atmxCesSvcConfigEntry/atmxCesSvcConfigRestart
  • /iso/org/dod/internet/private/enterprise/xylan/xylanArch/xylanAtmArch/atmxCesGroup/atmxCesMIBObjects/atmxCesSvcConfigGroup/atmxCesSvcConfigTable/atmxCesSvcConfigEntry/atmxCesSvcConfigRestart
  • /iso/org/dod/internet/private/enterprises/xylan/xylanArch/xylanAtmArch/atmxCesGroup/atmxCesMIBObjects/atmxCesSvcConfigGroup/atmxCesSvcConfigTable/atmxCesSvcConfigEntry/atmxCesSvcConfigRestart
  • /iso/iso-identified-organization/dod/internet/private/enterprise/xylan/xylanArch/xylanAtmArch/atmxCesGroup/atmxCesMIBObjects/atmxCesSvcConfigGroup/atmxCesSvcConfigTable/atmxCesSvcConfigEntry/atmxCesSvcConfigRestart
  • /iso/iso-identified-organization/dod/internet/private/enterprises/xylan/xylanArch/xylanAtmArch/atmxCesGroup/atmxCesMIBObjects/atmxCesSvcConfigGroup/atmxCesSvcConfigTable/atmxCesSvcConfigEntry/atmxCesSvcConfigRestart
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/800/2/4/10/1/4/1/1/11

    Description by mibdepot

    When the value is set to 'restart' the active SVC
    is released if necessary and a new setup procedure
    is begun. As a result of this action, the
    atmxCesSvcConfigOperStatus object transitions to
    'establishmentInProgress' (if not already in this state)
    and the atmxCesRetryFailures object is cleared.

    When the value is set to 'noop' no operation is
    performed. When read, the value 'noop' is returned.

    Parsed from file xylan-ce.mib.txt
    Company: None
    Module: XYLAN-ATM-CE-MIB

    Description by circitor

    When the value is set to 'restart' the active SVC
    is released if necessary and a new setup procedure
    is begun. As a result of this action, the
    atmxCesSvcConfigOperStatus object transitions to
    'establishmentInProgress' (if not already in this state)
    and the atmxCesRetryFailures object is cleared.

    When the value is set to 'noop' no operation is
    performed. When read, the value 'noop' is returned.

    Parsed from file XYLAN-ATM-CE-MIB.mib
    Module: XYLAN-ATM-CE-MIB

    Information by oid_info

    Vendor: Xylan Corp.
    Module: XYLAN-ATM-CE-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    atmxCesSvcConfigRestart OBJECT-TYPE SYNTAX INTEGER { restart(1), noop(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When the value is set to 'restart' the active SVC is released if necessary and a new setup procedure is begun. As a result of this action, the atmxCesSvcConfigOperStatus object transitions to 'establishmentInProgress' (if not already in this state) and the atmxCesRetryFailures object is cleared. When the value is set to 'noop' no operation is performed. When read, the value 'noop' is returned." ::= { atmxCesSvcConfigEntry 11 }

    Information by circitor

    atmxCesSvcConfigRestart OBJECT-TYPE SYNTAX INTEGER { restart(1), noop(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When the value is set to 'restart' the active SVC is released if necessary and a new setup procedure is begun. As a result of this action, the atmxCesSvcConfigOperStatus object transitions to 'establishmentInProgress' (if not already in this state) and the atmxCesRetryFailures object is cleared. When the value is set to 'noop' no operation is performed. When read, the value 'noop' is returned." ::= { atmxCesSvcConfigEntry 11 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.800)

    Burt Cyr

    Brothers (13)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.1 atmxCesSvcSlotIndex 0 0 A unique value which identifies this HSM board slot.
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.2 atmxCesSvcPortIndex 0 0 A unique value which identifies this port.
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.3 atmxCesSvcVciIndex 0 0 The virtual channel identifier associated with the
    virtual connection.
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.4 atmxCesSvcRemoteAddr 0 0 The ATM address supporting the corresponding far end
    CES IWF process. If no address is supplied, no attempts
    to establish the ac…
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.5 atmxCesSvcRemoteVpi 0 0 The VPI number of the corresponding far end
    CES IWF process
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.6 atmxCesSvcRemoteVci 0 0 The VCI number of the corresponding far end
    CES IWF process
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.7 atmxCesSvcFirstRetryInterval 0 0 The time (in 10ths of a second unit) to wait
    before attempting to establish the SVC
    after the first failed call attempt. Zero re…
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.8 atmxCesSvcRetryTimer 0 0 Indicates the current value of the retry timer (in seconds) for
    this connection. When the value reaches zero an attempt
    will be …
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.9 atmxCesSvcRetryLimit 0 0 Sets a maximum limit on how many consecutive unsuccessful
    call setup attempts can be made before stopping the attempt
    to set up t…
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.10 atmxCesSvcRetryFailures 0 0 Indicates how many attempts to establish the connection
    have failed. This count is reset whenever a connection
    is successfully e…
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.12 atmxCesSvcConfigOperStatus 0 0 Describes the status of the active SVC. Valid values are:
    other - none of the types specified below
    establishmentInProgress - co…
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.13 atmxCesSvcLastReleaseCause 0 0 Value of the Cause field of the Cause information element
    in the last RELEASE signalling message received for this
    SVC. Indicate…
    1.3.6.1.4.1.800.2.4.10.1.4.1.1.14 atmxCesSvcLastReleaseDiagnostics 0 0 Value of the first 8 bytes of diagnostic information
    from the Cause field of the Cause information element
    in the last RELEASE si…