Reference record for OID 1.3.6.1.4.1.800.2.9.1.17.2



parent
1.3.6.1.4.1.800.2.9.1.17 (xylnatmClockingxCtrlGroup)
node code
2
node name
xylnatmClockingxGlobalCST
dot oid
1.3.6.1.4.1.800.2.9.1.17.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) xylan(800) xylanArch(2) xylanCsmArch(9) xylanCsmMIB(1) xylnatmClockingxCtrlGroup(17) xylnatmClockingxGlobalCST(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) xylan(800) xylanArch(2) xylanCsmArch(9) xylanCsmMIB(1) xylnatmClockingxCtrlGroup(17) xylnatmClockingxGlobalCST(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) xylan(800) xylanArch(2) xylanCsmArch(9) xylanCsmMIB(1) xylnatmClockingxCtrlGroup(17) xylnatmClockingxGlobalCST(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) xylan(800) xylanArch(2) xylanCsmArch(9) xylanCsmMIB(1) xylnatmClockingxCtrlGroup(17) xylnatmClockingxGlobalCST(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) xylan(800) xylanArch(2) xylanCsmArch(9) xylanCsmMIB(1) xylnatmClockingxCtrlGroup(17) xylnatmClockingxGlobalCST(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) xylan(800) xylanArch(2) xylanCsmArch(9) xylanCsmMIB(1) xylnatmClockingxCtrlGroup(17) xylnatmClockingxGlobalCST(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/xylan/xylanArch/xylanCsmArch/xylanCsmMIB/xylnatmClockingxCtrlGroup/xylnatmClockingxGlobalCST
  • /iso/identified-organization/dod/internet/private/enterprises/xylan/xylanArch/xylanCsmArch/xylanCsmMIB/xylnatmClockingxCtrlGroup/xylnatmClockingxGlobalCST
  • /iso/org/dod/internet/private/enterprise/xylan/xylanArch/xylanCsmArch/xylanCsmMIB/xylnatmClockingxCtrlGroup/xylnatmClockingxGlobalCST
  • /iso/org/dod/internet/private/enterprises/xylan/xylanArch/xylanCsmArch/xylanCsmMIB/xylnatmClockingxCtrlGroup/xylnatmClockingxGlobalCST
  • /iso/iso-identified-organization/dod/internet/private/enterprise/xylan/xylanArch/xylanCsmArch/xylanCsmMIB/xylnatmClockingxCtrlGroup/xylnatmClockingxGlobalCST
  • /iso/iso-identified-organization/dod/internet/private/enterprises/xylan/xylanArch/xylanCsmArch/xylanCsmMIB/xylnatmClockingxCtrlGroup/xylnatmClockingxGlobalCST
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/800/2/9/1/17/2

    Description by mibdepot

    This object is used to specify the time period
    (in seconds) that the primary clock source
    should be up before the switching software
    resumes its role in driving the bus line.
    If the clock source goes down within this
    time period, the secondary source continues
    to drive the bus line. This prevents the
    software from doing the switching too often when
    the clock source isn't stable.

    Parsed from file xylan-csm.mib.txt
    Company: None
    Module: XYLAN-CSM-MIB

    Description by circitor

    This object is used to specify the time period
    (in seconds) that the primary clock source
    should be up before the switching software
    resumes its role in driving the bus line.
    If the clock source goes down within this
    time period, the secondary source continues
    to drive the bus line. This prevents the
    software from doing the switching too often when
    the clock source isn't stable.

    Parsed from file XYLAN-CSM-MIB.mib
    Module: XYLAN-CSM-MIB

    Information by oid_info

    Vendor: Xylan Corp.
    Module: XYLAN-CSM-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    xylnatmClockingxGlobalCST OBJECT-TYPE SYNTAX INTEGER (1..10000) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to specify the time period (in seconds) that the primary clock source should be up before the switching software resumes its role in driving the bus line. If the clock source goes down within this time period, the secondary source continues to drive the bus line. This prevents the software from doing the switching too often when the clock source isn't stable." ::= { xylnatmClockingxCtrlGroup 2 }

    Information by circitor

    xylnatmClockingxGlobalCST OBJECT-TYPE SYNTAX INTEGER (1..10000) ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to specify the time period (in seconds) that the primary clock source should be up before the switching software resumes its role in driving the bus line. If the clock source goes down within this time period, the secondary source continues to drive the bus line. This prevents the software from doing the switching too often when the clock source isn't stable." ::= { xylnatmClockingxCtrlGroup 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.800)

    Burt Cyr

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.800.2.9.1.17.2.0 xylnatmClockingxGlobalCST 0 0 None

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.800.2.9.1.17.1 xylnatmClockingxCtrlTable 1 7 A table of Clocking configuration and control information.