The initial value for the Hello Timer.
In the absence of triggered Hellos, this node will send one
Hello packet on each of its ports on this interval.
Parsed from file xylan-pnni.mib.txt
Company: None
Module: XPNNI-MIB
The initial value for the Hello Timer.
In the absence of triggered Hellos, this node will send one
Hello packet on each of its ports on this interval.
Parsed from file XPNNI-MIB.mib
Module: XPNNI-MIB
Vendor: Xylan Corp.
Module: XPNNI-MIB
[Automatically extracted from oidview.com]
pnnixNodeHelloInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The initial value for the Hello Timer. In the absence of triggered Hellos, this node will send one Hello packet on each of its ports on this interval." ::= { pnnixNodeTimerEntry 3 }
pnnixNodeHelloInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The initial value for the Hello Timer. In the absence of triggered Hellos, this node will send one Hello packet on each of its ports on this interval." ::= { pnnixNodeTimerEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.800.3.2.1.1.1.4.1.1 | pnnixNodePtseHolddown | 0 | 0 | The initial value for the PTSE hold down timer that will be used by the given node to limit the rate at which it can re-originate… |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.2 | pnnixNodeHelloHolddown | 0 | 0 | The initial value for the Hello hold down timer that will be used by the given node to limit the rate at which it sends Hellos. I… |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.4 | pnnixNodeHelloInactivityFactor | 0 | 0 | The value for the Hello Inactivity factor that this node will use to determine when a neighbor has gone down. |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.5 | pnnixNodeHlinkInact | 0 | 0 | The amount of time a node will continue to advertise a horizontal (logical) link for which it has not received and processed a LG… |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.6 | pnnixNodePtseRefreshInterval | 0 | 0 | The initial value for the Refresh timer that this node will use to drive (re-)origination of PTSEs in the absence of triggered up… |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.7 | pnnixNodePtseLifetimeFactor | 0 | 0 | The value for the lifetime multiplier, expressed as a percentage. The result of multiplying the pnnixNodePtseRefreshInterval att… |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.8 | pnnixNodeRxmtInterval | 0 | 0 | The period between retransmissions of unacknowledged Database Summary packets, PTSE Request packets, and PTSPs. |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.9 | pnnixNodePeerDelayedAckInterval | 0 | 0 | The minimum amount of time between transmissions of delayed PTSE acknowledgement packets. |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.10 | pnnixNodeAvcrPm | 0 | 0 | The proportional multiplier used in the algorithms that determine significant change for AvCR parameters, expressed as a percenta… |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.11 | pnnixNodeAvcrMt | 0 | 0 | The minimum threshold used in the algorithms that determine significant change for AvCR parameters, expressed as a percentage. |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.12 | pnnixNodeCdvPm | 0 | 0 | The proportional multiplier used in the algorithms that determine significant change for CDV metrics, expressed as a percentage. |
1.3.6.1.4.1.800.3.2.1.1.1.4.1.13 | pnnixNodeCtdPm | 0 | 0 | The proportional multiplier used in the algorithms that determine significant change for CTD metrics, expressed as a percentage. |