Reference record for OID 1.3.6.1.4.1.818.1.1.11.9.7



parent
1.3.6.1.4.1.818.1.1.11.9 (upsConfig_first)
node code
7
node name
upsConfigLowBattTime_first
dot oid
1.3.6.1.4.1.818.1.1.11.9.7
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsConfig_first(9) upsConfigLowBattTime_first(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsConfig_first(9) upsConfigLowBattTime_first(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsConfig_first(9) upsConfigLowBattTime_first(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsConfig_first(9) upsConfigLowBattTime_first(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsConfig_first(9) upsConfigLowBattTime_first(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFirstUPS(11) upsConfig_first(9) upsConfigLowBattTime_first(7)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFirstUPS/upsConfig_first/upsConfigLowBattTime_first
  • /iso/identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFirstUPS/upsConfig_first/upsConfigLowBattTime_first
  • /iso/org/dod/internet/private/enterprise/imv/geHardware/geUPS/geFirstUPS/upsConfig_first/upsConfigLowBattTime_first
  • /iso/org/dod/internet/private/enterprises/imv/geHardware/geUPS/geFirstUPS/upsConfig_first/upsConfigLowBattTime_first
  • /iso/iso-identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFirstUPS/upsConfig_first/upsConfigLowBattTime_first
  • /iso/iso-identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFirstUPS/upsConfig_first/upsConfigLowBattTime_first
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/818/1/1/11/9/7

    Description by mibdepot

    The value of upsEstimatedMinutesRemaining at which a
    lowBattery condition is declared. For agents which
    support only discrete (discontinuous) values, then the
    agent shall round up to the next supported value. If
    the requested value is larger than the largest
    supported value, then the largest supported value
    shall be selected.(*)

    Parsed from file GE_PARALLELUPS.mib.txt
    Company: ge
    Module: GE_PARALLELUPS

    Information by oid_info

    Vendor: IMV Victron bv
    Module: GE_PARALLELUPS

    [Automatically extracted from oidview.com]

    Information by mibdepot

    upsConfigLowBattTime_first OBJECT-TYPE SYNTAX NonNegativeInteger32 UNITS "minutes" MAX-ACCESS read-write STATUS current DESCRIPTION "The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.(*)" ::= { upsConfig_first 7 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.818)

    Versteeg Theo

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.11.9.7.0 0 0 0 upsConfigLowBattTime_first

    Brothers (13)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.11.9.1 upsConfigInputVoltage_first 1 1 The magnitude of the nominal input voltage. On those
    systems which support read-write access to this
    object, if there is an atte…
    1.3.6.1.4.1.818.1.1.11.9.2 upsConfigInputFreq_first 1 1 The nominal input frequency. On those systems which
    support read-write access to this object, if there is
    an attempt to set this…
    1.3.6.1.4.1.818.1.1.11.9.3 upsConfigOutputVoltage_first 1 1 The magnitude of the nominal output voltage. On
    those systems which support read-write access to this
    object, if there is an att…
    1.3.6.1.4.1.818.1.1.11.9.4 upsConfigOutputFreq_first 1 1 The nominal output frequency. On those systems which
    support read-write access to this object, if there is
    an attempt to set thi…
    1.3.6.1.4.1.818.1.1.11.9.5 upsConfigOutputVA_first 1 1 The magnitude of the nominal Volt-Amp rating.(*)
    1.3.6.1.4.1.818.1.1.11.9.6 upsConfigOutputPower_first 1 1 The magnitude of the nominal true power rating.(*)
    1.3.6.1.4.1.818.1.1.11.9.8 upsConfigAudibleStatus_first 1 1 The requested state of the audible alarm. When in
    the disabled state, the audible alarm should never
    sound. The enabled state i…
    1.3.6.1.4.1.818.1.1.11.9.9 upsConfigLowVoltageTransferPoint_first 1 1 The minimum input line voltage allowed before the UPS
    system transfers to battery backup.(*)
    1.3.6.1.4.1.818.1.1.11.9.10 upsConfigHighVoltageTransferPoint_first 1 1 The maximum line voltage allowed before the UPS
    system transfers to battery backup.(*)
    1.3.6.1.4.1.818.1.1.11.9.11 upsConfigBatteryCapacity_first 1 1 The installed battery capacity. This value is the 'factory'-value,
    not the value after calibration.
    1.3.6.1.4.1.818.1.1.11.9.12 upsConfigBatteryChargeCurrent_first 1 1 The maximum battery charge current, including external chargers.
    1.3.6.1.4.1.818.1.1.11.9.13 upsConfigNoLoadShutdown_first 1 1 Dis- or enable 'no load' shutdown from the contact interface.
    1.3.6.1.4.1.818.1.1.11.9.14 upsConfigStartDelay_first 1 1 Minimum required autonomy time before the UPS may perform an
    autorestart.