Reference record for OID 1.3.6.1.4.1.818.1.1.12.7.3



parent
1.3.6.1.4.1.818.1.1.12.7 (upsTest_second)
node code
3
node name
upsTestResultsSummary_second
dot oid
1.3.6.1.4.1.818.1.1.12.7.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geSecondUPS(12) upsTest_second(7) upsTestResultsSummary_second(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geSecondUPS(12) upsTest_second(7) upsTestResultsSummary_second(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geSecondUPS(12) upsTest_second(7) upsTestResultsSummary_second(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geSecondUPS(12) upsTest_second(7) upsTestResultsSummary_second(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geSecondUPS(12) upsTest_second(7) upsTestResultsSummary_second(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geSecondUPS(12) upsTest_second(7) upsTestResultsSummary_second(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geSecondUPS/upsTest_second/upsTestResultsSummary_second
  • /iso/identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geSecondUPS/upsTest_second/upsTestResultsSummary_second
  • /iso/org/dod/internet/private/enterprise/imv/geHardware/geUPS/geSecondUPS/upsTest_second/upsTestResultsSummary_second
  • /iso/org/dod/internet/private/enterprises/imv/geHardware/geUPS/geSecondUPS/upsTest_second/upsTestResultsSummary_second
  • /iso/iso-identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geSecondUPS/upsTest_second/upsTestResultsSummary_second
  • /iso/iso-identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geSecondUPS/upsTest_second/upsTestResultsSummary_second
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/818/1/1/12/7/3

    Description by mibdepot

    The results of the current or last UPS diagnostics
    test performed. The values for donePass(1),
    doneWarning(2), and doneError(3) indicate that the
    test completed either successfully, with a warning, or
    with an error, respectively. The value aborted(4) is
    returned for tests which are aborted by setting the
    value of upsTestId to upsTestAbortTestInProgress.
    Tests which have not yet concluded are indicated by
    inProgress(5). The value noTestsInitiated(6)
    indicates that no previous test results are available,
    such as is the case when no tests have been run since
    the last reinitialization of the network management
    subsystem and the system has no provision for non-
    volatile storage of test results.(*)

    Parsed from file GE_PARALLELUPS.mib.txt
    Company: ge
    Module: GE_PARALLELUPS

    Information by oid_info

    Vendor: IMV Victron bv
    Module: GE_PARALLELUPS

    [Automatically extracted from oidview.com]

    Information by mibdepot

    upsTestResultsSummary_second OBJECT-TYPE SYNTAX Integer32 { donePass(1), doneWarning(2), doneError(3), aborted(4), inProgress(5), noTestsInitiated(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The results of the current or last UPS diagnostics test performed. The values for donePass(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.(*)" ::= { upsTest_second 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.818)

    Versteeg Theo

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.12.7.3.0 0 0 0 upsTestResultsSummary_second

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.12.7.1 upsTestId_second 1 1 The test is named by an OBJECT IDENTIFIER which
    allows a standard mechanism for the initiation of
    tests, including the well known…
    1.3.6.1.4.1.818.1.1.12.7.2 upsTestSpinLock_second 1 1 A spin lock on the test subsystem. The spinlock is
    used as follows.

    Before starting a test, a manager-station should make
    sure th…
    1.3.6.1.4.1.818.1.1.12.7.4 upsTestResultsDetail_second 1 1 Additional information about upsTestResultsSummary.
    If no additional information available, a zero length
    string is returned.(*)
    1.3.6.1.4.1.818.1.1.12.7.5 upsTestStartTime_second 1 1 The value of sysUpTime at the time the test in
    progress was initiated, or, if no test is in progress,
    the time the previous test …
    1.3.6.1.4.1.818.1.1.12.7.6 upsTestElapsedTime_second 1 1 The amount of time, in TimeTicks, since the test in
    progress was initiated, or, if no test is in progress,
    the previous test took…
    1.3.6.1.4.1.818.1.1.12.7.7 upsWellKnownTests_second 5 5 None