Reference record for OID 1.3.6.1.4.1.818.1.1.14.2.4



parent
1.3.6.1.4.1.818.1.1.14.2 (upsBattery_fourth)
node code
4
node name
upsEstimatedChargeRemaining_fourth
dot oid
1.3.6.1.4.1.818.1.1.14.2.4
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsBattery_fourth(2) upsEstimatedChargeRemaining_fourth(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsBattery_fourth(2) upsEstimatedChargeRemaining_fourth(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsBattery_fourth(2) upsEstimatedChargeRemaining_fourth(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsBattery_fourth(2) upsEstimatedChargeRemaining_fourth(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsBattery_fourth(2) upsEstimatedChargeRemaining_fourth(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) imv(818) geHardware(1) geUPS(1) geFourthUPS(14) upsBattery_fourth(2) upsEstimatedChargeRemaining_fourth(4)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFourthUPS/upsBattery_fourth/upsEstimatedChargeRemaining_fourth
  • /iso/identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFourthUPS/upsBattery_fourth/upsEstimatedChargeRemaining_fourth
  • /iso/org/dod/internet/private/enterprise/imv/geHardware/geUPS/geFourthUPS/upsBattery_fourth/upsEstimatedChargeRemaining_fourth
  • /iso/org/dod/internet/private/enterprises/imv/geHardware/geUPS/geFourthUPS/upsBattery_fourth/upsEstimatedChargeRemaining_fourth
  • /iso/iso-identified-organization/dod/internet/private/enterprise/imv/geHardware/geUPS/geFourthUPS/upsBattery_fourth/upsEstimatedChargeRemaining_fourth
  • /iso/iso-identified-organization/dod/internet/private/enterprises/imv/geHardware/geUPS/geFourthUPS/upsBattery_fourth/upsEstimatedChargeRemaining_fourth
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/818/1/1/14/2/4

    Description by mibdepot

    An estimate of the battery charge remaining expressed
    as a percent of full charge.(*)

    Parsed from file GE_PARALLELUPS.mib.txt
    Company: ge
    Module: GE_PARALLELUPS

    Information by oid_info

    Vendor: IMV Victron bv
    Module: GE_PARALLELUPS

    [Automatically extracted from oidview.com]

    Information by mibdepot

    upsEstimatedChargeRemaining_fourth OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "An estimate of the battery charge remaining expressed as a percent of full charge.(*)" ::= { upsBattery_fourth 4 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.818)

    Versteeg Theo

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.14.2.4.0 0 0 0 upsEstimatedChargeRemaining_fourth

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.818.1.1.14.2.1 upsBatteryStatus_fourth 1 1 The indication of the capacity remaining in the UPS
    system's batteries. A value of batteryNormal
    indicates that the remaining r…
    1.3.6.1.4.1.818.1.1.14.2.2 upsSecondsOnBattery_fourth 1 1 If the unit is on battery power, the elapsed time
    since the UPS last switched to battery power, or the
    time since the network man…
    1.3.6.1.4.1.818.1.1.14.2.3 upsEstimatedMinutesRemaining_fourth 1 1 An estimate of the time to battery charge depletion
    under the present load conditions if the utility power
    is off and remains off…
    1.3.6.1.4.1.818.1.1.14.2.5 upsBatteryVoltage_fourth 1 1 The magnitude of the present battery voltage.(*)
    1.3.6.1.4.1.818.1.1.14.2.6 upsBatteryCurrent_fourth 1 1 The present battery current.(*)
    1.3.6.1.4.1.818.1.1.14.2.7 upsBatteryTemperature_fourth 1 1 The ambient temperature at or near the UPS Battery
    casing.(*)