A upsShutdownAfterDelay countdown is underway.(*)
Parsed from file GE_PARALLELUPS.mib.txt
Company: ge
Module: GE_PARALLELUPS
Vendor: IMV Victron bv
Module: GE_PARALLELUPS
[Automatically extracted from oidview.com]
upsAlarmShutdownPending_eighth OBJECT-IDENTITY STATUS current DESCRIPTION "A upsShutdownAfterDelay countdown is underway.(*)" ::= { upsWellKnownAlarms_eighth 22 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.818.1.1.18.6.3.1 | upsAlarmBatteryBad_eighth | 0 | 0 | One or more batteries have been determined to require replacement.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.2 | upsAlarmOnBattery_eighth | 0 | 0 | The UPS is drawing power from the batteries.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.3 | upsAlarmLowBattery_eighth | 0 | 0 | The remaining battery run-time is less than or equal to upsConfigLowBattTime.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.4 | upsAlarmDepletedBattery_eighth | 0 | 0 | The UPS will be unable to sustain the present load when and if the utility power is lost.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.5 | upsAlarmTempBad_eighth | 0 | 0 | A temperature is out of tolerance.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.6 | upsAlarmInputBad_eighth | 0 | 0 | An input condition is out of tolerance.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.7 | upsAlarmOutputBad_eighth | 0 | 0 | An output condition (other than OutputOverload) is out of tolerance.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.8 | upsAlarmOutputOverload_eighth | 0 | 0 | The output load exceeds the UPS output capacity.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.9 | upsAlarmOnBypass_eighth | 0 | 0 | The Bypass is presently engaged on the UPS.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.10 | upsAlarmBypassBad_eighth | 0 | 0 | The Bypass is out of tolerance.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.11 | upsAlarmOutputOffAsRequested_eighth | 0 | 0 | The UPS has shutdown as requested, i.e., the output is off.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.12 | upsAlarmUpsOffAsRequested_eighth | 0 | 0 | The entire UPS has shutdown as commanded.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.13 | upsAlarmChargerFailed_eighth | 0 | 0 | An uncorrected problem has been detected within the UPS charger subsystem.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.14 | upsAlarmUpsOutputOff_eighth | 0 | 0 | The output of the UPS is in the off state.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.15 | upsAlarmUpsSystemOff_eighth | 0 | 0 | The UPS system is in the off state.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.16 | upsAlarmFanFailure_eighth | 0 | 0 | The failure of one or more fans in the UPS has been detected.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.17 | upsAlarmFuseFailure_eighth | 0 | 0 | The failure of one or more fuses has been detected.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.18 | upsAlarmGeneralFault_eighth | 0 | 0 | A general fault in the UPS has been detected.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.19 | upsAlarmDiagnosticTestFailed_eighth | 0 | 0 | The result of the last diagnostic test indicates a failure.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.20 | upsAlarmCommunicationsLost_eighth | 0 | 0 | A problem has been encountered in the communications between the agent and the UPS.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.21 | upsAlarmAwaitingPower_eighth | 0 | 0 | The UPS output is off and the UPS is awaiting the return of input power.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.23 | upsAlarmShutdownImminent_eighth | 0 | 0 | The UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.(*) |
1.3.6.1.4.1.818.1.1.18.6.3.24 | upsAlarmTestInProgress_eighth | 0 | 0 | A test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanism… |
1.3.6.1.4.1.818.1.1.18.6.3.25 | upsAlarmReceptacleOff_eighth | 0 | 0 | The receptacle are switch off |