Used to report the value of sysUpTime for the
last successful poll by the ProbePoller application.
This value is reported by the ProbePoller when
an slaMonitorPollerTrapTimeout is issued. A value
of 0 indicates there has not been a successful poll.
Parsed from file sla.mi2.txt
Company: lucent
Module: XEDIA-SLA-MONITOR-MIB
slaMonitorPollerLastUpTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS not-accessible STATUS current DESCRIPTION "Used to report the value of sysUpTime for the last successful poll by the ProbePoller application. This value is reported by the ProbePoller when an slaMonitorPollerTrapTimeout is issued. A value of 0 indicates there has not been a successful poll." DEFVAL { 0 } ::= { slaMonitorGlobalObjects 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.838.3.27.1.1 | slaMonitorProbeConfigurationTimeLastModification | 0 | 0 | The value of sysUpTime the last time an entry in the slaMonitorProbeResultsTable was updated. |
1.3.6.1.4.1.838.3.27.1.2 | slaMonitorAutomaticProbeCreation | 0 | 0 | If the value of this object is 'true(1)', then a monitor probe with default values will be created and will begin executing upon … |
1.3.6.1.4.1.838.3.27.1.3 | slaMonitorCurrentProbeResultsIndex | 0 | 0 | The current value of the index to the slaMonitorProbeResultsTable. |
1.3.6.1.4.1.838.3.27.1.4 | slaMonitorProbeRetries | 0 | 0 | The number of times a probe packet will be retried when no response is received in the timeout interval indicated by slaMonitorPr… |
1.3.6.1.4.1.838.3.27.1.5 | slaMonitorProbeTimeout | 0 | 0 | The time to wait, in seconds, before retransmission of an probe packet. |
1.3.6.1.4.1.838.3.27.1.6 | slaMonitorProbePort | 0 | 0 | The UDP port that will be used to transmit and receive probe packets. |
1.3.6.1.4.1.838.3.27.1.7 | slaMonitorProbeDefaultMaxResults | 0 | 0 | The default value for the maximum number of probe results kept in the slaMonitorProbeResultsTable for newly created probes. |
1.3.6.1.4.1.838.3.27.1.8 | slaMonitorProbeSequenceStart | 0 | 0 | The time, in seconds since 1970, when probe packet processing was begun by this box, since the last reboot. Used to identify all… |
1.3.6.1.4.1.838.3.27.1.9 | slaMonitorProbeDefaultProbingInterval | 0 | 0 | The default value for the interval in seconds between sending of probe packets. A value of 0 means that no probes will be sent. |
1.3.6.1.4.1.838.3.27.1.10 | slaMonitorProbeSendAdminStatus | 0 | 0 | Whether the box is capable of sending probe packets. |
1.3.6.1.4.1.838.3.27.1.11 | slaMonitorProbeReceiveAdminStatus | 0 | 0 | Whether the box is capable of receiving probe packets. |