Reference record for OID 1.3.6.1.4.1.855.2.4.1.2.3



parent
1.3.6.1.4.1.855.2.4.1.2 (upsBattery)
node code
3
node name
upsBatteryNormallyOpenNormallyClosed
dot oid
1.3.6.1.4.1.855.2.4.1.2.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsBattery(2) upsBatteryNormallyOpenNormallyClosed(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsBattery(2) upsBatteryNormallyOpenNormallyClosed(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsBattery(2) upsBatteryNormallyOpenNormallyClosed(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsBattery(2) upsBatteryNormallyOpenNormallyClosed(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsBattery(2) upsBatteryNormallyOpenNormallyClosed(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) sec(855) powermon(2) powermonUPS4(4) ups(1) upsBattery(2) upsBatteryNormallyOpenNormallyClosed(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/sec/powermon/powermonUPS4/ups/upsBattery/upsBatteryNormallyOpenNormallyClosed
  • /iso/identified-organization/dod/internet/private/enterprises/sec/powermon/powermonUPS4/ups/upsBattery/upsBatteryNormallyOpenNormallyClosed
  • /iso/org/dod/internet/private/enterprise/sec/powermon/powermonUPS4/ups/upsBattery/upsBatteryNormallyOpenNormallyClosed
  • /iso/org/dod/internet/private/enterprises/sec/powermon/powermonUPS4/ups/upsBattery/upsBatteryNormallyOpenNormallyClosed
  • /iso/iso-identified-organization/dod/internet/private/enterprise/sec/powermon/powermonUPS4/ups/upsBattery/upsBatteryNormallyOpenNormallyClosed
  • /iso/iso-identified-organization/dod/internet/private/enterprises/sec/powermon/powermonUPS4/ups/upsBattery/upsBatteryNormallyOpenNormallyClosed
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/855/2/4/1/2/3

    Description by mibdepot

    This object defines the normal state of the POWER FAIL and LO BATTERY
    input lines from the UPS. The possible values are ncnc(3), nono(4),
    ncno(5), nonc(6). The first two letters indicate the normal state
    of the POWER FAIL input line and the second two letters indicate
    the normal state of the LO BATTERY input line, with 'nc'='normally closed'
    and 'no'='normally open'

    Parsed from file POWERMN4.MIB.txt
    Company: cai
    Module: POWERMON4-MIB

    Information by oid_info

    Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.

    Information by mibdepot

    upsBatteryNormallyOpenNormallyClosed OBJECT-TYPE SYNTAX INTEGER { ncnc(3), nono(4), ncno(5), nonc(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This object defines the normal state of the POWER FAIL and LO BATTERY input lines from the UPS. The possible values are ncnc(3), nono(4), ncno(5), nonc(6). The first two letters indicate the normal state of the POWER FAIL input line and the second two letters indicate the normal state of the LO BATTERY input line, with 'nc'='normally closed' and 'no'='normally open'" ::= { upsBattery 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.855)

    Held Steve

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.855.2.4.1.2.3.0 upsBatteryNormallyOpenNormallyClosed 0 0 None

    Brothers (2)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.855.2.4.1.2.1 upsBatteryOperation 1 1 The current operations state of the UPS (line or battery).
    1.3.6.1.4.1.855.2.4.1.2.2 upsBatteryStatus 1 1 This object indicates the State of the Battery. unknown(1),
    batteryNormal(2), batteryLow(3), batteryDepleted(4).