This table defines the characteristics of the
serial line interfaces.
It is not possible to add or delete an entry of
this table (each entry corresponds, in
fcfPhysicalPortTable, to one instance of
fcfInterfaceType equal to 'line').
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
This table defines the characteristics of the
serial line interfaces.
It is not possible to add or delete an entry of
this table (each entry corresponds, in
fcfPhysicalPortTable, to one instance of
fcfInterfaceType equal to 'line').
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fcfLineTable OBJECT-TYPE SYNTAX SEQUENCE OF FcfLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines the characteristics of the serial line interfaces. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfPhysicalPortTable, to one instance of fcfInterfaceType equal to 'line')." ::= { fcfLines 1 }
fcfLineTable OBJECT-TYPE SYNTAX SEQUENCE OF FcfLineEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines the characteristics of the serial line interfaces. It is not possible to add or delete an entry of this table (each entry corresponds, in fcfPhysicalPortTable, to one instance of fcfInterfaceType equal to 'line')." ::= { fcfLines 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.10.2.1.1 | fcfLineEntry | 6 | 6 | An entry of fcfLineTable. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.10.2.5 | fcfLineV28AsynOutDteSignalTable | 1 | 7 | This table defines how the outgoing circuits are used on asynchronous V28 serial line interfaces when the equipment is a DTE. It i… |
1.3.6.1.4.1.866.20.1.10.2.6 | fcfLineV28AsynOutDceSignalTable | 1 | 7 | This table defines how the outgoing circuits are used on asynchronous V28 serial line interfaces when the equipment is a DCE. It i… |
1.3.6.1.4.1.866.20.1.10.2.7 | fcfLineV28AsynInDteSignalTable | 1 | 6 | This table defines how the incoming circuits are interpreted on asynchronous V28 serial line interfaces when the equipment is a D… |
1.3.6.1.4.1.866.20.1.10.2.8 | fcfLineV28AsynInDceSignalTable | 1 | 6 | This table defines how the incoming circuits are interpreted on asynchronous V28 serial line interfaces when the equipment is a D… |
1.3.6.1.4.1.866.20.1.10.2.11 | fcfLineV28DteSignalTable | 1 | 8 | This table defines how the incoming circuits are monitored and interpreted on synchronous V28 serial line interfaces when the equ… |
1.3.6.1.4.1.866.20.1.10.2.12 | fcfLineV28DceSignalTable | 1 | 8 | This table defines how the incoming circuits are monitored and interpreted on synchronous V28 serial line interfaces when the equ… |
1.3.6.1.4.1.866.20.1.10.2.15 | fcfLineV11DteSignalTable | 1 | 4 | This table defines how the incoming circuits are monitored and interpreted on synchronous V11 serial line interfaces when the equ… |
1.3.6.1.4.1.866.20.1.10.2.16 | fcfLineV11DceSignalTable | 1 | 4 | This table defines how the incoming circuits are monitored and interpreted on synchronous V11 serial line interfaces when the equ… |
1.3.6.1.4.1.866.20.1.10.2.19 | fcfLineV35DteSignalTable | 1 | 7 | This table defines how the incoming circuits are monitored and interpreted on V35 serial line interfaces when the equipment is a … |
1.3.6.1.4.1.866.20.1.10.2.20 | fcfLineV35DceSignalTable | 1 | 7 | This table defines how the incoming circuits are monitored and interpreted on V35 serial line interfaces when the equipment is a … |
1.3.6.1.4.1.866.20.1.10.2.30 | fcfLineModem | 2 | 21 | None |
1.3.6.1.4.1.866.20.1.10.2.31 | fcfLineDVBTable | 1 | 4 | None |