Reference record for OID 1.3.6.1.4.1.866.20.1.10.2.11.1.5



parent
1.3.6.1.4.1.866.20.1.10.2.11.1 (fcfLineV28DteSignalEntry)
node code
5
node name
fcfLineV28DteSi117
dot oid
1.3.6.1.4.1.866.20.1.10.2.11.1.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcInterfaces(10) fcfLines(2) fcfLineV28DteSignalTable(11) fcfLineV28DteSignalEntry(1) fcfLineV28DteSi117(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcInterfaces(10) fcfLines(2) fcfLineV28DteSignalTable(11) fcfLineV28DteSignalEntry(1) fcfLineV28DteSi117(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcInterfaces(10) fcfLines(2) fcfLineV28DteSignalTable(11) fcfLineV28DteSignalEntry(1) fcfLineV28DteSi117(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcInterfaces(10) fcfLines(2) fcfLineV28DteSignalTable(11) fcfLineV28DteSignalEntry(1) fcfLineV28DteSi117(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcInterfaces(10) fcfLines(2) fcfLineV28DteSignalTable(11) fcfLineV28DteSignalEntry(1) fcfLineV28DteSi117(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcInterfaces(10) fcfLines(2) fcfLineV28DteSignalTable(11) fcfLineV28DteSignalEntry(1) fcfLineV28DteSi117(5)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcInterfaces/fcfLines/fcfLineV28DteSignalTable/fcfLineV28DteSignalEntry/fcfLineV28DteSi117
  • /iso/identified-organization/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcInterfaces/fcfLines/fcfLineV28DteSignalTable/fcfLineV28DteSignalEntry/fcfLineV28DteSi117
  • /iso/org/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcInterfaces/fcfLines/fcfLineV28DteSignalTable/fcfLineV28DteSignalEntry/fcfLineV28DteSi117
  • /iso/org/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcInterfaces/fcfLines/fcfLineV28DteSignalTable/fcfLineV28DteSignalEntry/fcfLineV28DteSi117
  • /iso/iso-identified-organization/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcInterfaces/fcfLines/fcfLineV28DteSignalTable/fcfLineV28DteSignalEntry/fcfLineV28DteSi117
  • /iso/iso-identified-organization/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcInterfaces/fcfLines/fcfLineV28DteSignalTable/fcfLineV28DteSignalEntry/fcfLineV28DteSi117
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/866/20/1/10/2/11/1/5

    Description by mibdepot

    The value of this object defines how the circuit
    117 (standby indicator) is monitored to eventually
    generate the corresponding event when its state
    changes and, when it is monitored, how it is
    scanned to determine whether this serial line
    interface is up or down.

    notMonitored : this circuit is not used,
    monitoredNotSignificant : this circuit is
    monitored (eventually events are
    generated) but it is not scanned to
    determine the state of this serial line
    interface,
    monitoredOff : this circuit is monitored
    (eventually events are generated) and it
    must be in the OFF condition to determine
    that this serial line interface is in the
    UP state,
    monitoredOn : this circuit is monitored
    (eventually events are generated) and it
    must be in the ON condition to determine
    that this serial line interface is in the
    UP state.

    The default value is 'notMonitored'.

    Parsed from file v42ami1e.mib.txt
    Company: None
    Module: PCE-MIB

    Description by circitor

    The value of this object defines how the circuit
    117 (standby indicator) is monitored to eventually
    generate the corresponding event when its state
    changes and, when it is monitored, how it is
    scanned to determine whether this serial line
    interface is up or down.

    notMonitored : this circuit is not used,
    monitoredNotSignificant : this circuit is
    monitored (eventually events are
    generated) but it is not scanned to
    determine the state of this serial line
    interface,
    monitoredOff : this circuit is monitored
    (eventually events are generated) and it
    must be in the OFF condition to determine
    that this serial line interface is in the
    UP state,
    monitoredOn : this circuit is monitored
    (eventually events are generated) and it
    must be in the ON condition to determine
    that this serial line interface is in the
    UP state.

    The default value is 'notMonitored'.

    Parsed from file PCE-MIB.mib
    Module: PCE-MIB

    Information by oid_info

    Vendor: Philips Communication d'Entreprise Claude Lubin
    Module: PCE-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    fcfLineV28DteSi117 OBJECT-TYPE SYNTAX INTEGER { notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object defines how the circuit 117 (standby indicator) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'." ::= { fcfLineV28DteSignalEntry 5 }

    Information by circitor

    fcfLineV28DteSi117 OBJECT-TYPE SYNTAX INTEGER { notMonitored(1), monitoredNotSignificant(2), monitoredOff(3), monitoredOn(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object defines how the circuit 117 (standby indicator) is monitored to eventually generate the corresponding event when its state changes and, when it is monitored, how it is scanned to determine whether this serial line interface is up or down. notMonitored : this circuit is not used, monitoredNotSignificant : this circuit is monitored (eventually events are generated) but it is not scanned to determine the state of this serial line interface, monitoredOff : this circuit is monitored (eventually events are generated) and it must be in the OFF condition to determine that this serial line interface is in the UP state, monitoredOn : this circuit is monitored (eventually events are generated) and it must be in the ON condition to determine that this serial line interface is in the UP state. The default value is 'notMonitored'." ::= { fcfLineV28DteSignalEntry 5 }

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.866.20.1.10.2.11.1.1 fcfLineV28DteInterfaceId 0 0 The value of this object identifies one and only
    one synchronous V28 DTE serial line interface.
    Each synchronous V28 DTE serial l…
    1.3.6.1.4.1.866.20.1.10.2.11.1.2 fcfLineV28DteCts106 0 0 The value of this object defines how the circuit
    106 (ready fo sending) is monitored to eventually
    generate the corresponding eve…
    1.3.6.1.4.1.866.20.1.10.2.11.1.3 fcfLineV28DteDsr107 0 0 The value of this object defines how the circuit
    107 (data set ready) is monitored to eventually
    generate the corresponding event…
    1.3.6.1.4.1.866.20.1.10.2.11.1.4 fcfLineV28DteDcd109 0 0 The value of this object defines how the circuit
    109 (data channel received line signal detector)
    is monitored to eventually gene…
    1.3.6.1.4.1.866.20.1.10.2.11.1.6 fcfLineV28DteTi142 0 0 The value of this object defines how the circuit
    142 (test indicator) is monitored to eventually
    generate the corresponding event…
    1.3.6.1.4.1.866.20.1.10.2.11.1.7 fcfLineV28DteSyn 0 0 The value of this object defines how the flags are
    checked to determine whether this serial line
    interface is up or down.

    notMonit…