The value of this object defines which circuits
are scanned to determine whether this serial line
interface is up or down. Main circuits may also be
simultaneously scanned (see
fcfLineV28AsynInDceEnablingSig1).
none : the circuits 111, 140, 141 are not used.
If also the circuits 105 and 108 are not
used the state of this interface is
determined by another method,
drs111 : the circuit 111 (data signal rate
selector) is used,
ril140 : the circuit 140 (loopback /
maintenance test) is used,
ll141 : the circuit 141 (local loopback) is
used.
The default value is 'none'.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
The value of this object defines which circuits
are scanned to determine whether this serial line
interface is up or down. Main circuits may also be
simultaneously scanned (see
fcfLineV28AsynInDceEnablingSig1).
none : the circuits 111, 140, 141 are not used.
If also the circuits 105 and 108 are not
used the state of this interface is
determined by another method,
drs111 : the circuit 111 (data signal rate
selector) is used,
ril140 : the circuit 140 (loopback /
maintenance test) is used,
ll141 : the circuit 141 (local loopback) is
used.
The default value is 'none'.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fcfLineV28AsynInDceEnablingSig2 OBJECT-TYPE SYNTAX INTEGER { none(1), drs111(2), ril140(3), ll141(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object defines which circuits are scanned to determine whether this serial line interface is up or down. Main circuits may also be simultaneously scanned (see fcfLineV28AsynInDceEnablingSig1). none : the circuits 111, 140, 141 are not used. If also the circuits 105 and 108 are not used the state of this interface is determined by another method, drs111 : the circuit 111 (data signal rate selector) is used, ril140 : the circuit 140 (loopback / maintenance test) is used, ll141 : the circuit 141 (local loopback) is used. The default value is 'none'." ::= { fcfLineV28AsynInDceSignalEntry 3 }
fcfLineV28AsynInDceEnablingSig2 OBJECT-TYPE SYNTAX INTEGER { none(1), drs111(2), ril140(3), ll141(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object defines which circuits are scanned to determine whether this serial line interface is up or down. Main circuits may also be simultaneously scanned (see fcfLineV28AsynInDceEnablingSig1). none : the circuits 111, 140, 141 are not used. If also the circuits 105 and 108 are not used the state of this interface is determined by another method, drs111 : the circuit 111 (data signal rate selector) is used, ril140 : the circuit 140 (loopback / maintenance test) is used, ll141 : the circuit 141 (local loopback) is used. The default value is 'none'." ::= { fcfLineV28AsynInDceSignalEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.10.2.8.1.1 | fcfLineV28AsynInDceInterfaceId | 0 | 0 | The value of this object identifies one and only one asynchronous V28 DCE serial line interface. Each asynchronous V28 DCE serial… |
1.3.6.1.4.1.866.20.1.10.2.8.1.2 | fcfLineV28AsynInDceEnablingSig1 | 0 | 0 | The value of this object defines which circuits are scanned to determine whether this serial line interface is up or down. Second… |
1.3.6.1.4.1.866.20.1.10.2.8.1.4 | fcfLineV28AsynInDceSigMonitored1 | 0 | 0 | The value of this object defines which circuits are monitored to eventually generate the corresponding event when the state of on… |
1.3.6.1.4.1.866.20.1.10.2.8.1.5 | fcfLineV28AsynInDceSigMonitored2 | 0 | 0 | The value of this object defines which circuits are monitored to eventually generate the corresponding event when the state of on… |