An entry of fclFraLogPortTable.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
An entry of fclFraLogPortTable.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fclFraLogPortEntry OBJECT-TYPE SYNTAX FclFraLogPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of fclFraLogPortTable." INDEX { fclFraLpLogPortId } ::= { fclFraLogPortTable 1 }
fclFraLogPortEntry OBJECT-TYPE SYNTAX FclFraLogPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry of fclFraLogPortTable." INDEX { fclFraLpLogPortId } ::= { fclFraLogPortTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.20.13.1.1.1 | fclFraLpLogPortId | 0 | 0 | The value of this object identifies one and only one Frame Relay Access logical port. The possible values are : '0..131'. If it i… |
1.3.6.1.4.1.866.20.1.20.13.1.1.2 | fclFraLpInterfaceId | 0 | 0 | The value of this object identifies the line interface used by this FRA logical port. The possible values are : '0..35'. If it is… |
1.3.6.1.4.1.866.20.1.20.13.1.1.3 | fclFraLpLmi | 0 | 0 | The value of this object defines which kind of signalling is used on this FRA logical port. The possible values are 'off' (no sig… |
1.3.6.1.4.1.866.20.1.20.13.1.1.5 | fclFraLpGroupingThreshold | 0 | 0 | The value of this object is the input resource threshold over which several input frames coming from a FR PVC end point are group… |
1.3.6.1.4.1.866.20.1.20.13.1.1.6 | fclFraLpFecnBecnThreshold | 0 | 0 | The value of this object is the input resource threshold over which bits FECN (Forward Explicit Congestion Notification) of input… |
1.3.6.1.4.1.866.20.1.20.13.1.1.7 | fclFraLpDeDiscardThreshold | 0 | 0 | The value of this object is the input resource threshold over which input frames with bit DE (Discard Eligible) set to 1 are disc… |
1.3.6.1.4.1.866.20.1.20.13.1.1.8 | fclFraLpAllDiscardThreshold | 0 | 0 | The value of this object is the input resource threshold over which all input frames are discarded (i.e. : not sent accross the X… |
1.3.6.1.4.1.866.20.1.20.13.1.1.9 | fclFraLpX25InterframeFlagCount | 0 | 0 | The value of this object is the number of interframe flags (it concerns the framing aspects of link access procedures of X25 and … |
1.3.6.1.4.1.866.20.1.20.13.1.1.10 | fclFraLpInactivityCheckDelay | 0 | 0 | The value of this object is the inactivity check delay in minutes.............. The possible values are : '0..254'. The value '0'… |
1.3.6.1.4.1.866.20.1.20.13.1.1.20 | fclFraLpCompression | 0 | 0 | The value of this object indicates the compression enabling for each direction. The authorized values are : off : no compression, n… |
1.3.6.1.4.1.866.20.1.20.13.1.1.21 | fclFraLpCompressNegotiation | 0 | 0 | The value of this object indicates whether the compression facility is negociated or not and, if negociated, the optional/obligat… |
1.3.6.1.4.1.866.20.1.20.13.1.1.22 | fclFraLpCompressScrambling | 0 | 0 | The value of this object indicates, when the compression is active, whether the scrambling is enabled or not. The default value i… |
1.3.6.1.4.1.866.20.1.20.13.1.1.23 | fclFraLpCompressMultiPacketsTimer | 0 | 0 | The value of this object defines the maximum waiting time, in milliseconds by steps of 100 milliseconds , which, if there is not … |
1.3.6.1.4.1.866.20.1.20.13.1.1.24 | fclFraLpReliableVc | 0 | 0 | The value of this object is used to enable the Reliable Virtual Circuit service. The authorized values are : off : no RVC, the VCs… |