The value of this object is the maximum number
(MW) of sequentially numbered multilink frames
that the DCE or DTE may transfer which the lowest
numbered multilink frame which has not yet been
acknowledged beyond. This parameter shall have the
same value for both switching points. The
authorized values are '1..32'. The default value
is '32'.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
The value of this object is the maximum number
(MW) of sequentially numbered multilink frames
that the DCE or DTE may transfer which the lowest
numbered multilink frame which has not yet been
acknowledged beyond. This parameter shall have the
same value for both switching points. The
authorized values are '1..32'. The default value
is '32'.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fclX25MlpMwMultilinkWindowSize OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the maximum number (MW) of sequentially numbered multilink frames that the DCE or DTE may transfer which the lowest numbered multilink frame which has not yet been acknowledged beyond. This parameter shall have the same value for both switching points. The authorized values are '1..32'. The default value is '32'." ::= { fclX25MlpParameterEntry 2 }
fclX25MlpMwMultilinkWindowSize OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the maximum number (MW) of sequentially numbered multilink frames that the DCE or DTE may transfer which the lowest numbered multilink frame which has not yet been acknowledged beyond. This parameter shall have the same value for both switching points. The authorized values are '1..32'. The default value is '32'." ::= { fclX25MlpParameterEntry 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.20.25.2.1.1 | fclX25MlpParamLogPortId | 0 | 0 | The value of this object identifies one and only one X25 MLP (Multi-Link Protocol) inter-node logical port. The possible values a… |
1.3.6.1.4.1.866.20.1.20.25.2.1.3 | fclX25MlpRxMlpMxWinGuardRegion | 0 | 0 | The value of this object defines a guard region (MX) of multilink sequence numbers of fixed size. The range of MX shall be large … |
1.3.6.1.4.1.866.20.1.20.25.2.1.4 | fclX25MlpMt1LostFrameTimer | 0 | 0 | The value of this object defines the timer (MT1), in seconds, which a transmitted frames is declared lost beyond. The authorized … |
1.3.6.1.4.1.866.20.1.20.25.2.1.5 | fclX25MlpMt3ResetConfirmationTimer | 0 | 0 | The value of this object defines the maximum time (MT3), in seconds, between a reset request and a reset confirmation, which the … |
1.3.6.1.4.1.866.20.1.20.25.2.1.6 | fclX25MlpMt4DownLinkDetectionTimer | 0 | 0 | The value of this object defines the timer (MT4), in seconds, which the line is declared down beyond. The line is out if all the … |
1.3.6.1.4.1.866.20.1.20.25.2.1.7 | fclX25MlpFramesMaxCountByLink | 0 | 0 | The value of this object is the maximum number of transmitted frames on a line. The authorized values are '1..255'. The default v… |
1.3.6.1.4.1.866.20.1.20.25.2.1.8 | fclX25MlpRestartTxAfterResetRx | 0 | 0 | The value of this object indicates if there is recovery after MLP reset. The authorized values are 'off' or 'on'. The default val… |
1.3.6.1.4.1.866.20.1.20.25.2.1.9 | fclX25MlpTns3Level3CheckTimer | 0 | 0 | The value of this object defines the timer, in seconds, between a sending of frames and the reception of its acknowledges, which … |