The value of this object indicates the number of
bytes received by the equipment in the receive
buffers. The authorized values are '1..128'. The
default value is '128'.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
The value of this object indicates the number of
bytes received by the equipment in the receive
buffers. The authorized values are '1..128'. The
default value is '128'.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fclAsynCfgLinkBlockSize OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object indicates the number of bytes received by the equipment in the receive buffers. The authorized values are '1..128'. The default value is '128'." ::= { fclAsynCfgConnLinkEntry 9 }
fclAsynCfgLinkBlockSize OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object indicates the number of bytes received by the equipment in the receive buffers. The authorized values are '1..128'. The default value is '128'." ::= { fclAsynCfgConnLinkEntry 9 }
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.866.20.1.20.5.10.21.1.1 | fclAsynCfgLinkConfigId | 0 | 0 | The value of this object identifies one and only one asynchronous configuration. The possible values are : '0..199. If it is unus… |
| 1.3.6.1.4.1.866.20.1.20.5.10.21.1.2 | fclAsynCfgLinkXonXoffParity | 0 | 0 | The value of this object indicates the XON/XOFF parity. The default value is 'even'. |
| 1.3.6.1.4.1.866.20.1.20.5.10.21.1.3 | fclAsynCfgLinkServSignalParity | 0 | 0 | The value of this object indicates the signals parity. The default value is 'even'. |
| 1.3.6.1.4.1.866.20.1.20.5.10.21.1.4 | fclAsynCfgLinkDataParity | 0 | 0 | The value of this object indicates the data parity. The default value is 'even'. |
| 1.3.6.1.4.1.866.20.1.20.5.10.21.1.5 | fclAsynCfgLinkBitCount | 0 | 0 | The value of this object indicates the number of bits by characters. The authorized values are '7' or '8'. The default value is '… |
| 1.3.6.1.4.1.866.20.1.20.5.10.21.1.6 | fclAsynCfgLinkStopBitCount | 0 | 0 | The value of this object defines the number of stop bits. The default value is 'one'. |
| 1.3.6.1.4.1.866.20.1.20.5.10.21.1.7 | fclAsynCfgLinkXonXoffSignal | 0 | 0 | The value of this object indicates if there are a transmission of XOFF when moving to the command mode and a transmission of XON … |
| 1.3.6.1.4.1.866.20.1.20.5.10.21.1.8 | fclAsynCfgLinkInactivityTimer | 0 | 0 | The value of this object defines the line inactivity time-out in transfer state. When the time-out expires, the call is cleared. … |
| 1.3.6.1.4.1.866.20.1.20.5.10.21.1.10 | fclAsynCfgLinkCallResponseTimer | 0 | 0 | The value of this object is the supervision time-out for response to a call request packet sent on the link. A clear packet is se… |