The value of this object identifies one and only
one X25 access configuration. This configuration
may be referenced by fclX25AccX25AccessConfigId,
fclX25InDX25AccessConfigId,
fclX25InDIsdnRemX25AccConfigId or
fclX25InBRemX25ConfigId.
The possible values are : '0..199. If it is
unused, the value of this parameter is '255'.
The X25 access configuration parameters are
described in :
fclX25CfaDataLinkNetworkTable : data link and
network levels,
fclX25CfaFacilityTable : facility level,
fclX25CfaNegotiatedFacilityTable : facility
level (negotiaitions),
fclX25CfaSignallingTable : signalling level,
fclX25CfaServiceTable : services level.
When creating a new configuration each parameter
takes its default value. Setting a profile allows
the user to fill all the parameters with values
pre-defined in this profile but each one may also
be individually modified.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
The value of this object identifies one and only
one X25 access configuration. This configuration
may be referenced by fclX25AccX25AccessConfigId,
fclX25InDX25AccessConfigId,
fclX25InDIsdnRemX25AccConfigId or
fclX25InBRemX25ConfigId.
The possible values are : '0..199. If it is
unused, the value of this parameter is '255'.
The X25 access configuration parameters are
described in :
fclX25CfaDataLinkNetworkTable : data link and
network levels,
fclX25CfaFacilityTable : facility level,
fclX25CfaNegotiatedFacilityTable : facility
level (negotiaitions),
fclX25CfaSignallingTable : signalling level,
fclX25CfaServiceTable : services level.
When creating a new configuration each parameter
takes its default value. Setting a profile allows
the user to fill all the parameters with values
pre-defined in this profile but each one may also
be individually modified.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fclX25CfaConfigId OBJECT-TYPE SYNTAX INTEGER (0..199) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies one and only one X25 access configuration. This configuration may be referenced by fclX25AccX25AccessConfigId, fclX25InDX25AccessConfigId, fclX25InDIsdnRemX25AccConfigId or fclX25InBRemX25ConfigId. The possible values are : '0..199. If it is unused, the value of this parameter is '255'. The X25 access configuration parameters are described in : fclX25CfaDataLinkNetworkTable : data link and network levels, fclX25CfaFacilityTable : facility level, fclX25CfaNegotiatedFacilityTable : facility level (negotiaitions), fclX25CfaSignallingTable : signalling level, fclX25CfaServiceTable : services level. When creating a new configuration each parameter takes its default value. Setting a profile allows the user to fill all the parameters with values pre-defined in this profile but each one may also be individually modified." ::= { fclX25ConfigAccessEntry 1 }
fclX25CfaConfigId OBJECT-TYPE SYNTAX INTEGER (0..199) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies one and only one X25 access configuration. This configuration may be referenced by fclX25AccX25AccessConfigId, fclX25InDX25AccessConfigId, fclX25InDIsdnRemX25AccConfigId or fclX25InBRemX25ConfigId. The possible values are : '0..199. If it is unused, the value of this parameter is '255'. The X25 access configuration parameters are described in : fclX25CfaDataLinkNetworkTable : data link and network levels, fclX25CfaFacilityTable : facility level, fclX25CfaNegotiatedFacilityTable : facility level (negotiaitions), fclX25CfaSignallingTable : signalling level, fclX25CfaServiceTable : services level. When creating a new configuration each parameter takes its default value. Setting a profile allows the user to fill all the parameters with values pre-defined in this profile but each one may also be individually modified." ::= { fclX25ConfigAccessEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.20.50.1.1.1.2 | fclX25CfaStatus | 0 | 0 | The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid… |
1.3.6.1.4.1.866.20.1.20.50.1.1.1.3 | fclX25CfaDescription | 0 | 0 | The value of this object stores a text description of the X25 access configuration elaborated by the user. This description may c… |
1.3.6.1.4.1.866.20.1.20.50.1.1.1.4 | fclX25CfaProfileId | 0 | 0 | The value of this object is the profile number used to automatically valorize all the X25 parameters in an entry of the five tabl… |
1.3.6.1.4.1.866.20.1.20.50.1.1.1.5 | fclX25CfaModificationCount | 0 | 0 | The value of this object indicates how many X25 parameters have not the value defined in the profile specified by fclX25CfaProfil… |