This table defines the Closed User Groups to which
belong the subscribers. This table is used on a
link when fclX25CfaFacClosedUserGroup is set to
'subscribe' or 'subscribeAndRemove'.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
This table defines the Closed User Groups to which
belong the subscribers. This table is used on a
link when fclX25CfaFacClosedUserGroup is set to
'subscribe' or 'subscribeAndRemove'.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fclX25CfaClosedUserGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF FclX25CfaClosedUserGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines the Closed User Groups to which belong the subscribers. This table is used on a link when fclX25CfaFacClosedUserGroup is set to 'subscribe' or 'subscribeAndRemove'." ::= { fclX25ConfigAccess 51 }
fclX25CfaClosedUserGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF FclX25CfaClosedUserGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines the Closed User Groups to which belong the subscribers. This table is used on a link when fclX25CfaFacClosedUserGroup is set to 'subscribe' or 'subscribeAndRemove'." ::= { fclX25ConfigAccess 51 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.20.50.1.51.1 | fclX25CfaClosedUserGroupEntry | 5 | 5 | An entry of fclX25CfaClosedUserGroupTable. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.20.50.1.1 | fclX25ConfigAccessTable | 1 | 6 | This table contains the X25 access configurations used by X25 access links. |
1.3.6.1.4.1.866.20.1.20.50.1.10 | fclX25CfaDataLinkNetworkTable | 1 | 17 | This table contains the data link and network levels parameters of X25 access configurations. |
1.3.6.1.4.1.866.20.1.20.50.1.20 | fclX25CfaFacilityTable | 1 | 9 | This table contains the facility level parameters of X25 access configurations (except fast select, throughput class, packet size… |
1.3.6.1.4.1.866.20.1.20.50.1.21 | fclX25CfaNegotiatedFacilityTable | 1 | 21 | This table contains the facility level parameters of X25 access configurations (except closed user group, reverse charging, trans… |
1.3.6.1.4.1.866.20.1.20.50.1.30 | fclX25CfaSignallingTable | 1 | 19 | This table contains the signalling level parameters of X25 access configurations. |
1.3.6.1.4.1.866.20.1.20.50.1.40 | fclX25CfaServiceTable | 1 | 18 | This table contains the services level parameters of X25 access configurations. |
1.3.6.1.4.1.866.20.1.20.50.1.50 | fclX25CfaPackingAddresses | 4 | 11 | None |