The value of this object identifies one and only
one X25 inter-node configuration. This
configuration may be referenced by
fclX25InBRemX25ConfigId,
fclX25PstnX25InterNodeConfigId,
fclX25SlpX25InterNodeConfigId,
fclX25SlpIsdnRemX25InterNodeConfigId,
fclX25SlpPstnBackX25InterNodeConfigId,
fclX25MlpX25InterNodeConfigId or
fclFrPvcX25InterNodeConfigId.
The possible values are : '0..199. If it is
unused, the value of this parameter is '255'.
The X25 inter-node configuration parameters are
described in :
fclX25CfnaDataLinkNetworkTable : data link and
network levels,
fclX25CfnNegotiatedFacilityTable : facility
level,
fclX25CfnSignallingTable : signalling level,
fclX25CfnServiceTable : services level.
When creating a new configuration each parameter
takes its default value. Setting a profile allows
the user to fill all the parameters with values
pre-defined in this profile but each one may also
be individually modified.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
The value of this object identifies one and only
one X25 inter-node configuration. This
configuration may be referenced by
fclX25InBRemX25ConfigId,
fclX25PstnX25InterNodeConfigId,
fclX25SlpX25InterNodeConfigId,
fclX25SlpIsdnRemX25InterNodeConfigId,
fclX25SlpPstnBackX25InterNodeConfigId,
fclX25MlpX25InterNodeConfigId or
fclFrPvcX25InterNodeConfigId.
The possible values are : '0..199. If it is
unused, the value of this parameter is '255'.
The X25 inter-node configuration parameters are
described in :
fclX25CfnaDataLinkNetworkTable : data link and
network levels,
fclX25CfnNegotiatedFacilityTable : facility
level,
fclX25CfnSignallingTable : signalling level,
fclX25CfnServiceTable : services level.
When creating a new configuration each parameter
takes its default value. Setting a profile allows
the user to fill all the parameters with values
pre-defined in this profile but each one may also
be individually modified.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fclX25CfnConfigId OBJECT-TYPE SYNTAX INTEGER (0..199) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies one and only one X25 inter-node configuration. This configuration may be referenced by fclX25InBRemX25ConfigId, fclX25PstnX25InterNodeConfigId, fclX25SlpX25InterNodeConfigId, fclX25SlpIsdnRemX25InterNodeConfigId, fclX25SlpPstnBackX25InterNodeConfigId, fclX25MlpX25InterNodeConfigId or fclFrPvcX25InterNodeConfigId. The possible values are : '0..199. If it is unused, the value of this parameter is '255'. The X25 inter-node configuration parameters are described in : fclX25CfnaDataLinkNetworkTable : data link and network levels, fclX25CfnNegotiatedFacilityTable : facility level, fclX25CfnSignallingTable : signalling level, fclX25CfnServiceTable : services level. When creating a new configuration each parameter takes its default value. Setting a profile allows the user to fill all the parameters with values pre-defined in this profile but each one may also be individually modified." ::= { fclX25ConfigInterNodeEntry 1 }
fclX25CfnConfigId OBJECT-TYPE SYNTAX INTEGER (0..199) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies one and only one X25 inter-node configuration. This configuration may be referenced by fclX25InBRemX25ConfigId, fclX25PstnX25InterNodeConfigId, fclX25SlpX25InterNodeConfigId, fclX25SlpIsdnRemX25InterNodeConfigId, fclX25SlpPstnBackX25InterNodeConfigId, fclX25MlpX25InterNodeConfigId or fclFrPvcX25InterNodeConfigId. The possible values are : '0..199. If it is unused, the value of this parameter is '255'. The X25 inter-node configuration parameters are described in : fclX25CfnaDataLinkNetworkTable : data link and network levels, fclX25CfnNegotiatedFacilityTable : facility level, fclX25CfnSignallingTable : signalling level, fclX25CfnServiceTable : services level. When creating a new configuration each parameter takes its default value. Setting a profile allows the user to fill all the parameters with values pre-defined in this profile but each one may also be individually modified." ::= { fclX25ConfigInterNodeEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.20.50.10.1.1.2 | fclX25CfnStatus | 0 | 0 | The value of this object indicates the state of the entry of this table. The default value is 'valid'. It must be set to 'invalid… |
1.3.6.1.4.1.866.20.1.20.50.10.1.1.3 | fclX25CfnDescription | 0 | 0 | The value of this object stores a text description of the X25 inter-node configuration elaborated by the user. This description m… |
1.3.6.1.4.1.866.20.1.20.50.10.1.1.4 | fclX25CfnProfileId | 0 | 0 | The value of this object is the profile number used to automatically valorize all the X25 parameters in an entry of the four tabl… |
1.3.6.1.4.1.866.20.1.20.50.10.1.1.5 | fclX25CfnModificationCount | 0 | 0 | The value of this object indicates how many X25 parameters have not the value defined in the profile specified by fclX25CfnProfil… |