Reference record for OID 1.3.6.1.4.1.866.20.1.20.50.30.2



parent
1.3.6.1.4.1.866.20.1.20.50.30 (fclX25ConfigMiscellaneous)
node code
2
node name
fclX25CfmTransmitFlowControl
dot oid
1.3.6.1.4.1.866.20.1.20.50.30.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigMiscellaneous(30) fclX25CfmTransmitFlowControl(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigMiscellaneous(30) fclX25CfmTransmitFlowControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigMiscellaneous(30) fclX25CfmTransmitFlowControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigMiscellaneous(30) fclX25CfmTransmitFlowControl(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigMiscellaneous(30) fclX25CfmTransmitFlowControl(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigMiscellaneous(30) fclX25CfmTransmitFlowControl(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigMiscellaneous/fclX25CfmTransmitFlowControl
  • /iso/identified-organization/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigMiscellaneous/fclX25CfmTransmitFlowControl
  • /iso/org/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigMiscellaneous/fclX25CfmTransmitFlowControl
  • /iso/org/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigMiscellaneous/fclX25CfmTransmitFlowControl
  • /iso/iso-identified-organization/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigMiscellaneous/fclX25CfmTransmitFlowControl
  • /iso/iso-identified-organization/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigMiscellaneous/fclX25CfmTransmitFlowControl
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/866/20/1/20/50/30/2

    Description by mibdepot

    The value of this object indicates whether the
    flow control is made according to the standard or
    according to fclX25CfmTransmitFlowControlTable
    (this way is used by TRANSPAC). The default value
    is 'standard'.

    Parsed from file v42ami1e.mib.txt
    Company: None
    Module: PCE-MIB

    Description by circitor

    The value of this object indicates whether the
    flow control is made according to the standard or
    according to fclX25CfmTransmitFlowControlTable
    (this way is used by TRANSPAC). The default value
    is 'standard'.

    Parsed from file PCE-MIB.mib
    Module: PCE-MIB

    Information by oid_info

    Vendor: Philips Communication d'Entreprise Claude Lubin
    Module: PCE-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    fclX25CfmTransmitFlowControl OBJECT-TYPE SYNTAX INTEGER { standard(1), dedicatedTranspac(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object indicates whether the flow control is made according to the standard or according to fclX25CfmTransmitFlowControlTable (this way is used by TRANSPAC). The default value is 'standard'." ::= { fclX25ConfigMiscellaneous 2 }

    Information by circitor

    fclX25CfmTransmitFlowControl OBJECT-TYPE SYNTAX INTEGER { standard(1), dedicatedTranspac(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object indicates whether the flow control is made according to the standard or according to fclX25CfmTransmitFlowControlTable (this way is used by TRANSPAC). The default value is 'standard'." ::= { fclX25ConfigMiscellaneous 2 }

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.866.20.1.20.50.30.2.0 fclX25CfmTransmitFlowControl 0 0 None

    Brothers (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.866.20.1.20.50.30.1 fclX25CfmDiagnosticCodeField 1 1 The value of this object indicates how the
    diagnostic field is encoded. The default value is
    'privateCoding'.
    1.3.6.1.4.1.866.20.1.20.50.30.3 fclX25CfmAddress14DigitsTruncation 1 1 The value of this object indicates whether the
    addresses are truncated to 14 digits or not. The
    default value is 'off'.
    1.3.6.1.4.1.866.20.1.20.50.30.20 fclX25CfmTransmitFlowControlTable 1 3 This table defines non standard flow control. This
    table is used if fclX25CfmTransmitFlowControl is
    set to 'dedicatedTranspac'.