Status of Fiber Link for this device
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cfetf105FiberLink OBJECT-TYPE SYNTAX INTEGER { linkUp(1), linkDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of Fiber Link for this device" ::= { cfetf105Entry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.14.1.1 | cfetf105BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.2 | cfetf105SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.3 | cfetf105Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.4 | cfetf105MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.5 | cfetf105CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.6 | cfetf105SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.7 | cfetf105ConnA | 0 | 0 | The style of Fiber connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.8 | cfetf105ConnB | 0 | 0 | The style of Copper connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.9 | cfetf105TPLink | 0 | 0 | Status of Twisted Pair Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.11 | cfetf105AutoNegot | 0 | 0 | Enable/Disable Autonegotiation |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.12 | cfetf105LinkPassThrough | 0 | 0 | Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to… |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.13 | cfetf105AutoCross | 0 | 0 | Enable/Disable for automatic copper TX/RX pair correction |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.14 | cfetf105TPActivity | 0 | 0 | Network traffic indicator for Copper side of this device |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.15 | cfetf105FiberActivity | 0 | 0 | Network traffic indicator for Fiber side of this device |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.16 | cfetf105ConfigMode | 0 | 0 | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP manageme… |
1.3.6.1.4.1.868.2.4.1.2.2.14.1.17 | cfetf105CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |