Reference record for OID 1.3.6.1.4.1.868.2.4.1.2.2.21.1.12



parent
1.3.6.1.4.1.868.2.4.1.2.2.21.1 (cfetf205Entry)
node code
12
node name
cfetf205FastLinkPulse
dot oid
1.3.6.1.4.1.868.2.4.1.2.2.21.1.12
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfetf205Table(21) cfetf205Entry(1) cfetf205FastLinkPulse(12)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfetf205Table(21) cfetf205Entry(1) cfetf205FastLinkPulse(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfetf205Table(21) cfetf205Entry(1) cfetf205FastLinkPulse(12)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfetf205Table(21) cfetf205Entry(1) cfetf205FastLinkPulse(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfetf205Table(21) cfetf205Entry(1) cfetf205FastLinkPulse(12)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfetf205Table(21) cfetf205Entry(1) cfetf205FastLinkPulse(12)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cfetf205Table/cfetf205Entry/cfetf205FastLinkPulse
  • /iso/identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cfetf205Table/cfetf205Entry/cfetf205FastLinkPulse
  • /iso/org/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cfetf205Table/cfetf205Entry/cfetf205FastLinkPulse
  • /iso/org/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cfetf205Table/cfetf205Entry/cfetf205FastLinkPulse
  • /iso/iso-identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cfetf205Table/cfetf205Entry/cfetf205FastLinkPulse
  • /iso/iso-identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cfetf205Table/cfetf205Entry/cfetf205FastLinkPulse
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/868/2/4/1/2/2/21/1/12

    Description by circitor

    When set to autonegotiate(1), converter sends
    Fast Link Pulses on its twisted pair port, thereby
    participating in autonegotiation of duplex between
    the converter's twisted pair port and that of the
    connected station. If that station supports Full-
    Duplex (FDX) operation, FDX will be used. If not, the
    twisted pair will operate in Half-Duplex (HDX) mode.
    When set to hdx100Btx(2), the converter instead sends
    100Mbps idles (rather than Fast Link Pulses) on its
    twisted pair port (i.e. it declines to negotiate), which
    forces the twisted pair to operate in HDX mode
    regardless of the capabilities of the connected station.
    When operating in HDX mode, the twisted pair can support
    traffic in only one direction at a time. In FDX mode,
    traffic can pass in both directions simultaneously, thus
    theoretically doubling network performance.

    Parsed from file MCC16-MIB.mib
    Module: MCC16-MIB

    Information by oid_info

    Vendor: Transition Engineering Inc.
    Module: MCC16-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cfetf205FastLinkPulse OBJECT-TYPE SYNTAX INTEGER { autonegotiate(1), hdx100Btx(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to autonegotiate(1), converter sends Fast Link Pulses on its twisted pair port, thereby participating in autonegotiation of duplex between the converter's twisted pair port and that of the connected station. If that station supports Full- Duplex (FDX) operation, FDX will be used. If not, the twisted pair will operate in Half-Duplex (HDX) mode. When set to hdx100Btx(2), the converter instead sends 100Mbps idles (rather than Fast Link Pulses) on its twisted pair port (i.e. it declines to negotiate), which forces the twisted pair to operate in HDX mode regardless of the capabilities of the connected station. When operating in HDX mode, the twisted pair can support traffic in only one direction at a time. In FDX mode, traffic can pass in both directions simultaneously, thus theoretically doubling network performance." ::= { cfetf205Entry 12 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.868)

    Trivedi Hemant

    Brothers (20)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.1 cfetf205BiaIndex 0 0 The serial number (BIA) of the cabinet in which the
    device is installed
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.2 cfetf205SlotIndex 0 0 The slot in which the device is installed
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.3 cfetf205Groups 0 0 User-defined keywords that group this device together with
    other devices under a user-defined scheme. By placing
    matching keyword…
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.4 cfetf205MRevision 0 0 The marketing revision of this device
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.5 cfetf205CfgMatch 0 0 yes(1) indicates that the conditions specified in
    cpsGroupCtrl.0 match the Groups value for this
    device. no(2) means that there i…
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.6 cfetf205SerialNumber 0 0 The serial number of this device
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.7 cfetf205ConnA 0 0 The style of Fiber connector built into this device
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.8 cfetf205ConnB 0 0 The style of Copper connector built into this device
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.9 cfetf205TPLink 0 0 Status of Twisted Pair Link for this device
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.10 cfetf205FiberLink 0 0 Status of Fiber Link for this device
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.11 cfetf205Fault 0 0 Value is yes(1) when either TPLink or FiberLink
    has value linkDown(2)
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.13 cfetf205Enabled 0 0 When this configuration item is set to no(2), the
    device passes no network traffic.
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.14 cfetf205Pause 0 0 The Pause feature allows Ethernet MACs that support it to
    send data pacing 'Pause' messages to each other.
    Support for Pause is n…
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.15 cfetf205LinkPassThrough 0 0 Enable/Disable for Link Pass Through, a feature that
    causes loss of link on one side of a media converter
    to be passed through to…
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.16 cfetf205AutoCross 0 0 Enable/Disable for automatic copper TX/RX pair correction.
    When disabled, the port operates in MDI mode.
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.17 cfetf205TPActivity 0 0 Network traffic indicator for Copper side of this device
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.18 cfetf205FiberActivity 0 0 Network traffic indicator for Fiber side of this device
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.19 cfetf205ConfigMode 0 0 This device has a jumper or switch that disables
    software management of the device. When ConfigMode is
    hardware(2), SNMP manageme…
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.20 cfetf205FarEndFault 0 0 Far End Fault configuration of this device. Far End Fault
    causes the fiber transmitter to generate a Far End Fault
    pattern upon …
    1.3.6.1.4.1.868.2.4.1.2.2.21.1.21 cfetf205CacheClean 0 0 When the value is clean(1)Device and Management Module
    cache are synchronized, no automatic corrections to
    configuration will occ…