When the value is clean(1)Device and Management Module
cache are synchronized, no automatic corrections to
configuration will occur. When the value is dirty(2)
Device and Management Module cache are not synchronized.
The configuration currently displayed by the application
has not been validated by the device. The device may
need to correct the configuration, in which case the
displayed configuration will change.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
csetf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { csetf100Entry 17 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.7.1.1 | csetf100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.2 | csetf100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.3 | csetf100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.4 | csetf100MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.5 | csetf100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.6 | csetf100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.7 | csetf100ConnA | 0 | 0 | The style of Fiber connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.8 | csetf100ConnB | 0 | 0 | The style of Copper connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.9 | csetf100TPLink | 0 | 0 | Status of Twisted Pair Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.10 | csetf100FiberLink | 0 | 0 | Status of Fiber Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.11 | csetf100AutoCross | 0 | 0 | Enable/Disable for automatic copper TX/RX pair correction |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.12 | csetf100SpeedConfig | 0 | 0 | This variable allows the user to set the requested data transfer rate for this converter. |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.13 | csetf100Speed100Mbps | 0 | 0 | This variable reports the current data transfer rate for this converter. |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.14 | csetf100TPActivity | 0 | 0 | Network traffic indicator for Copper side of this device |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.15 | csetf100FiberActivity | 0 | 0 | Network traffic indicator for Fiber side of this device |
1.3.6.1.4.1.868.2.4.1.2.2.7.1.16 | csetf100ConfigMode | 0 | 0 | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP manageme… |