This trap is used to inform network management system that a delta
fault event (events that are automatically cleared) has occured
or a normal fault event (not automatically cleared) state has
been set on.
Objects are used as follows:
- eventSeqNum is the sequence number of the event. For normal
type of events must equal to the sequence number of the event
in the events table.
- eventEventId specifies what fault event has occured.
- eventName specifies the name of the fault event.
- eventSetTime indicates when fault event has occured
(delta events) or when fault has been set on (normal events).
- eventSeverity reports the severity level of the event.
- eventInstanceType indicates what kind of object is faulty.
- eventInstanceId specifies what instance is faulty.
- eventInstanceName may contain textual description for
the faulty object.
- eventServAffective specifies whether the event is
immediately service affcetive.
- eventDescription reports possible additional information about the event.
- trapPersistence tells whether this event is a delta or normal event.
- trapSenderNodeId specifies the node ID of the sending network element if
configuring it is supported for the network element, otherwise 0.
- sysObjectID specifies what kind of equipment reports the fault event.
For more information see the eventTable specification
Parsed from file ZYXEL-ES2108-MIB.mib
Module: ZYXEL-ES2108-MIB
Vendor: ZyXEL Communications Corp.
Module: ZYXEL-ES2108-MIB
[Automatically extracted from oidview.com]
eventOnTrap NOTIFICATION-TYPE OBJECTS { eventSeqNum, eventEventId, eventName, eventSetTime, eventSeverity, eventInstanceType, eventInstanceId, eventInstanceName, eventServAffective, eventDescription, trapPersistence, trapSenderNodeId, sysObjectID} STATUS current DESCRIPTION "This trap is used to inform network management system that a delta fault event (events that are automatically cleared) has occured or a normal fault event (not automatically cleared) state has been set on. Objects are used as follows: - eventSeqNum is the sequence number of the event. For normal type of events must equal to the sequence number of the event in the events table. - eventEventId specifies what fault event has occured. - eventName specifies the name of the fault event. - eventSetTime indicates when fault event has occured (delta events) or when fault has been set on (normal events). - eventSeverity reports the severity level of the event. - eventInstanceType indicates what kind of object is faulty. - eventInstanceId specifies what instance is faulty. - eventInstanceName may contain textual description for the faulty object. - eventServAffective specifies whether the event is immediately service affcetive. - eventDescription reports possible additional information about the event. - trapPersistence tells whether this event is a delta or normal event. - trapSenderNodeId specifies the node ID of the sending network element if configuring it is supported for the network element, otherwise 0. - sysObjectID specifies what kind of equipment reports the fault event. For more information see the eventTable specification" ::= { trapNotifications 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.890.1.5.8.18.27.2.2 | eventClearedTrap | 0 | 0 | This trap is used to inform network management system that a normal type fault event has been cleared (state set off). Objects a… |