The number of times an IS-IS control PDU with a
max area address field different to that for this
system has been received.
Parsed from file CISCO-IETF-ISIS-MIB.mib
Module: CISCO-IETF-ISIS-MIB
The number of times an IS-IS control PDU with a
max area address field different to that for this
system has been received.
The number of times an IS-IS control PDU with a
max area address field different to that for this
system has been received.
Parsed from file CISCO-IETF-ISIS-MIB.my.txt
Company: None
Module: CISCO-IETF-ISIS-MIB
The number of times an IS-IS control PDU with a
max area address field different to that for this
system has been received.
ciiCircMaxAreaAddrMismatches OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times an IS-IS control PDU with a max area address field different to that for this system has been received." REFERENCE "{ISIS.aoi iDFieldLengthMismatches (25)}" ::= { ciiCircuitCounterEntry 7 }
ciiCircMaxAreaAddrMismatches OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times an IS-IS control PDU with a max area address field different to that for this system has been received." REFERENCE "{ISIS.aoi iDFieldLengthMismatches (25)}" ::= { ciiCircuitCounterEntry 7 }
Vendor: Cisco
Module: CISCO-IETF-ISIS-MIB
[Automatically extracted from oidview.com]
ciiCircMaxAreaAddrMismatches OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times an IS-IS control PDU with a max area address field different to that for this system has been received." REFERENCE "{ISIS.aoi iDFieldLengthMismatches (25)}" ::= { ciiCircuitCounterEntry 7 }
ciiCircMaxAreaAddrMismatches OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times an IS-IS control PDU with a max area address field different to that for this system has been received." REFERENCE "{ISIS.aoi iDFieldLengthMismatches (25)}" ::= { ciiCircuitCounterEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.10.118.1.5.2.1.1 | ciiCircuitType | 0 | 0 | What type of circuit saw these counts? The point to point Hello PDU includes both L1 and L2, and ISs form a single adjacency on po… |
1.3.6.1.4.1.9.10.118.1.5.2.1.2 | ciiCircAdjChanges | 0 | 0 | The number of times an adjacency state change has occurred on this circuit. |
1.3.6.1.4.1.9.10.118.1.5.2.1.3 | ciiCircNumAdj | 0 | 0 | The number of adjacencies on this circuit. |
1.3.6.1.4.1.9.10.118.1.5.2.1.4 | ciiCircInitFails | 0 | 0 | The number of times initialization of this circuit has failed. This counts events such as PPP NCP failures. Failures to form an … |
1.3.6.1.4.1.9.10.118.1.5.2.1.5 | ciiCircRejAdjs | 0 | 0 | The number of times an adjacency has been rejected on this circuit. |
1.3.6.1.4.1.9.10.118.1.5.2.1.6 | ciiCircIDFieldLenMismatches | 0 | 0 | The number of times an IS-IS control PDU with an ID field length different to that for this system has been received. |
1.3.6.1.4.1.9.10.118.1.5.2.1.8 | ciiCircAuthTypeFails | 0 | 0 | ciiCircAuthtypeFails |
1.3.6.1.4.1.9.10.118.1.5.2.1.9 | ciiCircAuthFails | 0 | 0 | The number of times an IS-IS control PDU with the correct auth type has failed to pass authentication validation. |
1.3.6.1.4.1.9.10.118.1.5.2.1.10 | ciiCircLANDesISChanges | 0 | 0 | The number of times the Designated IS has changed on this circuit at this level. If the circuit is point to point, this count is… |