The Compliance statement for the Cisco CDL MIB.
Parsed from file CISCO-CDL-MIB.mib
Module: CISCO-CDL-MIB
The Compliance statement for the Cisco CDL MIB.
Parsed from file CISCO-CDL-MIB.my.txt
Company: None
Module: CISCO-CDL-MIB
The Compliance statement for the Cisco CDL MIB.
coCdlMIBCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The Compliance statement for the Cisco CDL MIB." MODULE MANDATORY-GROUPS { coCdlMIBBaseGroup, coCdlDIAggMandatoryGroup, coCdlDIAggNotifGroup } OBJECT coCdlAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is required only when the presence of CDL is configurable on an Ethernet interface. " OBJECT coCdlDINotifyThrottleInterval MIN-ACCESS read-only DESCRIPTION "Write access is required only when the notify throttle interval is configurable. " OBJECT coCdlDefectIndSetSoakInterval MIN-ACCESS read-only DESCRIPTION "Write access is required only when the set soak interval is configurable. " OBJECT coCdlDefectIndClearSoakInterval MIN-ACCESS read-only DESCRIPTION "Write access is required only when the clear soak interval is configurable. " GROUP coCdlDIConfigGroup DESCRIPTION "This group is required when CDL defect indication behavior is configurable. " OBJECT coCdlForceEndOfHop MIN-ACCESS read-only DESCRIPTION "Write access is required only when the node behavior is configurable. " GROUP coCdlMIBFlowIdGroup DESCRIPTION "This group is required when the network element supports transport of CDL aggregate packet streams consisting of multiple elementary packet streams. " OBJECT coCdlTransmitMaxFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the maximum transmitted flow identifier value is configurable. " OBJECT coCdlReceiveMaxFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the maximum received flow identifier value is configurable. " GROUP coCdlMIBFlowTermGroup DESCRIPTION "This group is required when the network element supports termination of CDL packet-by-packet multiplexing, i.e., either the network element supports CDL packet-by-packet multiplexing and can apply/remove the CDL Ethernet encapsulation, or the network element contains interfaces that support packet-by-packet multiplexing as well as interfaces that do not support packet-by-packet multiplexing. " OBJECT coCdlToCdlNetFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the interface supports configuration of the flow identifier value progressed towards the CDL network. " OBJECT coCdlFromCdlNetFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the interface supports configuration of the flow identifier value received from the CDL network. " GROUP coCdlDIFlowNotifGroup DESCRIPTION "This group is required when the network element supports termination of CDL packet-by-packet multiplexing, i.e., either the network element supports CDL packet-by-packet multiplexing and can apply/remove the CDL Ethernet encapsulation, or the network element contains interfaces that support packet-by-packet multiplexing as well as interfaces that do not support packet-by-packet multiplexing. " ::= { coCdlMIBCompliances 1 }
coCdlMIBCompliance OBJECT IDENTIFIER ::= { coCdlMIBCompliances 1 }
Vendor: Cisco
Module: CISCO-CDL-MIB
[Automatically extracted from oidview.com]
coCdlMIBCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The Compliance statement for the Cisco CDL MIB." MODULE MANDATORY-GROUPS { coCdlMIBBaseGroup, coCdlDIAggMandatoryGroup, coCdlDIAggNotifGroup } OBJECT coCdlAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is required only when the presence of CDL is configurable on an Ethernet interface. " OBJECT coCdlDINotifyThrottleInterval MIN-ACCESS read-only DESCRIPTION "Write access is required only when the notify throttle interval is configurable. " OBJECT coCdlDefectIndSetSoakInterval MIN-ACCESS read-only DESCRIPTION "Write access is required only when the set soak interval is configurable. " OBJECT coCdlDefectIndClearSoakInterval MIN-ACCESS read-only DESCRIPTION "Write access is required only when the clear soak interval is configurable. " GROUP coCdlDIConfigGroup DESCRIPTION "This group is required when CDL defect indication behavior is configurable. " OBJECT coCdlForceEndOfHop MIN-ACCESS read-only DESCRIPTION "Write access is required only when the node behavior is configurable. " GROUP coCdlMIBFlowIdGroup DESCRIPTION "This group is required when the network element supports transport of CDL aggregate packet streams consisting of multiple elementary packet streams. " OBJECT coCdlTransmitMaxFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the maximum transmitted flow identifier value is configurable. " OBJECT coCdlReceiveMaxFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the maximum received flow identifier value is configurable. " GROUP coCdlMIBFlowTermGroup DESCRIPTION "This group is required when the network element supports termination of CDL packet-by-packet multiplexing, i.e., either the network element supports CDL packet-by-packet multiplexing and can apply/remove the CDL Ethernet encapsulation, or the network element contains interfaces that support packet-by-packet multiplexing as well as interfaces that do not support packet-by-packet multiplexing. " OBJECT coCdlToCdlNetFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the interface supports configuration of the flow identifier value progressed towards the CDL network. " OBJECT coCdlFromCdlNetFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the interface supports configuration of the flow identifier value received from the CDL network. " GROUP coCdlDIFlowNotifGroup DESCRIPTION "This group is required when the network element supports termination of CDL packet-by-packet multiplexing, i.e., either the network element supports CDL packet-by-packet multiplexing and can apply/remove the CDL Ethernet encapsulation, or the network element contains interfaces that support packet-by-packet multiplexing as well as interfaces that do not support packet-by-packet multiplexing. " ::= { coCdlMIBCompliances 1 }
coCdlMIBCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The Compliance statement for the Cisco CDL MIB." MODULE MANDATORY-GROUPS { coCdlMIBBaseGroup, coCdlDIAggMandatoryGroup, coCdlDIAggNotifGroup } OBJECT coCdlAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is required only when the presence of CDL is configurable on an Ethernet interface. " OBJECT coCdlDINotifyThrottleInterval MIN-ACCESS read-only DESCRIPTION "Write access is required only when the notify throttle interval is configurable. " OBJECT coCdlDefectIndSetSoakInterval MIN-ACCESS read-only DESCRIPTION "Write access is required only when the set soak interval is configurable. " OBJECT coCdlDefectIndClearSoakInterval MIN-ACCESS read-only DESCRIPTION "Write access is required only when the clear soak interval is configurable. " GROUP coCdlDIConfigGroup DESCRIPTION "This group is required when CDL defect indication behavior is configurable. " OBJECT coCdlForceEndOfHop MIN-ACCESS read-only DESCRIPTION "Write access is required only when the node behavior is configurable. " GROUP coCdlMIBFlowIdGroup DESCRIPTION "This group is required when the network element supports transport of CDL aggregate packet streams consisting of multiple elementary packet streams. " OBJECT coCdlTransmitMaxFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the maximum transmitted flow identifier value is configurable. " OBJECT coCdlReceiveMaxFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the maximum received flow identifier value is configurable. " GROUP coCdlMIBFlowTermGroup DESCRIPTION "This group is required when the network element supports termination of CDL packet-by-packet multiplexing, i.e., either the network element supports CDL packet-by-packet multiplexing and can apply/remove the CDL Ethernet encapsulation, or the network element contains interfaces that support packet-by-packet multiplexing as well as interfaces that do not support packet-by-packet multiplexing. " OBJECT coCdlToCdlNetFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the interface supports configuration of the flow identifier value progressed towards the CDL network. " OBJECT coCdlFromCdlNetFlowIdentifier MIN-ACCESS read-only DESCRIPTION "Write access is required only when the interface supports configuration of the flow identifier value received from the CDL network. " GROUP coCdlDIFlowNotifGroup DESCRIPTION "This group is required when the network element supports termination of CDL packet-by-packet multiplexing, i.e., either the network element supports CDL packet-by-packet multiplexing and can apply/remove the CDL Ethernet encapsulation, or the network element contains interfaces that support packet-by-packet multiplexing as well as interfaces that do not support packet-by-packet multiplexing. " ::= { coCdlMIBCompliances 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.10.88.3.1.2 | coCdlMIBCompliance2 | 0 | 0 | The Compliance statement for the Cisco CDL MIB. |