Reference record for OID 1.3.6.1.4.1.9.9.117.1.7.1.1.1



parent
1.3.6.1.4.1.9.9.117.1.7.1.1 (cefcChassisCoolingEntry)
node code
1
node name
cefcChassisPerSlotCoolingCap
dot oid
1.3.6.1.4.1.9.9.117.1.7.1.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoEntityFRUControlMIB(117) cefcMIBObjects(1) cefcCooling(7) cefcChassisCoolingTable(1) cefcChassisCoolingEntry(1) cefcChassisPerSlotCoolingCap(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoEntityFRUControlMIB(117) cefcMIBObjects(1) cefcCooling(7) cefcChassisCoolingTable(1) cefcChassisCoolingEntry(1) cefcChassisPerSlotCoolingCap(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoEntityFRUControlMIB(117) cefcMIBObjects(1) cefcCooling(7) cefcChassisCoolingTable(1) cefcChassisCoolingEntry(1) cefcChassisPerSlotCoolingCap(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoEntityFRUControlMIB(117) cefcMIBObjects(1) cefcCooling(7) cefcChassisCoolingTable(1) cefcChassisCoolingEntry(1) cefcChassisPerSlotCoolingCap(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoEntityFRUControlMIB(117) cefcMIBObjects(1) cefcCooling(7) cefcChassisCoolingTable(1) cefcChassisCoolingEntry(1) cefcChassisPerSlotCoolingCap(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoEntityFRUControlMIB(117) cefcMIBObjects(1) cefcCooling(7) cefcChassisCoolingTable(1) cefcChassisCoolingEntry(1) cefcChassisPerSlotCoolingCap(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoEntityFRUControlMIB/cefcMIBObjects/cefcCooling/cefcChassisCoolingTable/cefcChassisCoolingEntry/cefcChassisPerSlotCoolingCap
  • /iso/identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoEntityFRUControlMIB/cefcMIBObjects/cefcCooling/cefcChassisCoolingTable/cefcChassisCoolingEntry/cefcChassisPerSlotCoolingCap
  • /iso/org/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoEntityFRUControlMIB/cefcMIBObjects/cefcCooling/cefcChassisCoolingTable/cefcChassisCoolingEntry/cefcChassisPerSlotCoolingCap
  • /iso/org/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoEntityFRUControlMIB/cefcMIBObjects/cefcCooling/cefcChassisCoolingTable/cefcChassisCoolingEntry/cefcChassisPerSlotCoolingCap
  • /iso/iso-identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoEntityFRUControlMIB/cefcMIBObjects/cefcCooling/cefcChassisCoolingTable/cefcChassisCoolingEntry/cefcChassisPerSlotCoolingCap
  • /iso/iso-identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoEntityFRUControlMIB/cefcMIBObjects/cefcCooling/cefcChassisCoolingTable/cefcChassisCoolingEntry/cefcChassisPerSlotCoolingCap
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/9/9/117/1/7/1/1/1

    Description by circitor

    The maximum cooling capacity in the unit of CFM
    that could be provided for any slot in this
    chassis.

    Parsed from file CISCO-ENTITY-FRU-CONTROL-MIB.mib
    Module: CISCO-ENTITY-FRU-CONTROL-MIB

    Description by cisco_v1

    The maximum cooling capacity that could be provided
    for any slot in this chassis.

    The default unit of the cooling capacity is 'cfm', if
    cefcChassisPerSlotCoolingUnit is not supported.

    Description by mibdepot

    The maximum cooling capacity in the unit of CFM
    that could be provided for any slot in this
    chassis.

    Parsed from file cisco-entity-fru-control.mib.txt
    Company: None
    Module: CISCO-ENTITY-FRU-CONTROL-MIB

    Description by cisco

    The maximum cooling capacity that could be provided
    for any slot in this chassis.

    The default unit of the cooling capacity is 'cfm', if
    cefcChassisPerSlotCoolingUnit is not supported.

    Information by circitor

    cefcChassisPerSlotCoolingCap OBJECT-TYPE SYNTAX Unsigned32 UNITS "cfm" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum cooling capacity in the unit of CFM that could be provided for any slot in this chassis." ::= { cefcChassisCoolingEntry 1 }

    Information by cisco_v1

    cefcChassisPerSlotCoolingCap OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The maximum cooling capacity that could be provided for any slot in this chassis. The default unit of the cooling capacity is 'cfm', if cefcChassisPerSlotCoolingUnit is not supported." ::= { cefcChassisCoolingEntry 1 }

    Information by oid_info

    Vendor: Cisco
    Module: CISCO-ENTITY-FRU-CONTROL-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    cefcChassisPerSlotCoolingCap OBJECT-TYPE SYNTAX Unsigned32 UNITS "cfm" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum cooling capacity in the unit of CFM that could be provided for any slot in this chassis." ::= { cefcChassisCoolingEntry 1 }

    Information by cisco

    cefcChassisPerSlotCoolingCap OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum cooling capacity that could be provided for any slot in this chassis. The default unit of the cooling capacity is 'cfm', if cefcChassisPerSlotCoolingUnit is not supported." ::= { cefcChassisCoolingEntry 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.9)

    Greg Satz

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.9)

    Cisco Systems, Inc.

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.9.9.117.1.7.1.1.2 cefcChassisPerSlotCoolingUnit 0 0 The unit of the maximum cooling capacity for any slot
    in this chassis.