This parameter specifies the increment to the Near End alarm
integration counters. The local alarms are LOS and LOF. The
Default value is 6 and the integration counter is incremented by
this value every 10 ms while the alarm persists. The
counter is decremented by the value of 'cds3NEAlarmDownCount'
while there is no alarm (the counter does not decrement below
zero). When the integration counter exceeds 'cds3NEAlarmThreshold'
an Alarm of the severity specified for the particular Near End
alarm is declared.
Parsed from file CISCO-DS3-MIB.mib
Module: CISCO-DS3-MIB
This parameter specifies the increment to the Near End alarm
integration counters. The local alarms are LOS and LOF. The
Default value is 6 and the integration counter is incremented by
this value every 10 ms while the alarm persists. The
counter is decremented by the value of 'cds3NEAlarmDownCount'
while there is no alarm (the counter does not decrement below
zero). When the integration counter exceeds 'cds3NEAlarmThreshold'
an Alarm of the severity specified for the particular Near End
alarm is declared.
This parameter specifies the increment to the Near End alarm
integration counters. The local alarms are LOS and LOF. The
Default value is 6 and the integration counter is incremented by
this value every 10 ms while the alarm persists. The
counter is decremented by the value of 'cds3NEAlarmDownCount'
while there is no alarm (the counter does not decrement below
zero). When the integration counter exceeds 'cds3NEAlarmThreshold'
an Alarm of the severity specified for the particular Near End
alarm is declared.
Parsed from file CISCO-DS3-MIB.my.txt
Company: None
Module: CISCO-DS3-MIB
This parameter specifies the increment to the Near End alarm
integration counters. The local alarms are LOS and LOF. The
Default value is 6 and the integration counter is incremented by
this value every 10 ms while the alarm persists. The
counter is decremented by the value of 'cds3NEAlarmDownCount'
while there is no alarm (the counter does not decrement below
zero). When the integration counter exceeds 'cds3NEAlarmThreshold'
an Alarm of the severity specified for the particular Near End
alarm is declared.
cds3NEAlarmUpCount OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the increment to the Near End alarm integration counters. The local alarms are LOS and LOF. The Default value is 6 and the integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by the value of 'cds3NEAlarmDownCount' while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds 'cds3NEAlarmThreshold' an Alarm of the severity specified for the particular Near End alarm is declared." DEFVAL {6} ::= { cds3AlarmConfigEntry 1 }
cds3NEAlarmUpCount OBJECT-TYPE SYNTAX Gauge(0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the increment to the Near End alarm integration counters. The local alarms are LOS and LOF. The Default value is 6 and the integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by the value of 'cds3NEAlarmDownCount' while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds 'cds3NEAlarmThreshold' an Alarm of the severity specified for the particular Near End alarm is declared." DEFVAL { 6 } ::= { cds3AlarmConfigEntry 1 }
Vendor: Cisco
Module: CISCO-DS3-MIB
[Automatically extracted from oidview.com]
cds3NEAlarmUpCount OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the increment to the Near End alarm integration counters. The local alarms are LOS and LOF. The Default value is 6 and the integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by the value of 'cds3NEAlarmDownCount' while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds 'cds3NEAlarmThreshold' an Alarm of the severity specified for the particular Near End alarm is declared." DEFVAL {6} ::= { cds3AlarmConfigEntry 1 }
cds3NEAlarmUpCount OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter specifies the increment to the Near End alarm integration counters. The local alarms are LOS and LOF. The Default value is 6 and the integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by the value of 'cds3NEAlarmDownCount' while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds 'cds3NEAlarmThreshold' an Alarm of the severity specified for the particular Near End alarm is declared." DEFVAL {6} ::= { cds3AlarmConfigEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.132.1.2.1.1.1.2 | cds3NEAlarmDownCount | 0 | 0 | This parameter specifies the decrement to the Near End alarm integration counters. The alarms are LOS and LOF. The Default value… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.3 | cds3NEAlarmThreshold | 0 | 0 | The value set in this object determines the value that the alarm integration counter must reach for an near end alarm to be decla… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.4 | cds3FEAlarmUpCount | 0 | 0 | This parameter specifies the increment to the Far End alarm integration counters. The alarms are Remote Alarm Indication (RAI) a… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.5 | cds3FEAlarmDownCount | 0 | 0 | This parameter specifies the decrement to the Far End alarm integration counters. The alarms are Alarm Indication Signal (AIS) an… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.6 | cds3FEAlarmThreshold | 0 | 0 | The value set in this object determines the value that the alarm integration counter must reach for an far end Alarm to be declar… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.7 | cds3StatisticalAlarmSeverity | 0 | 0 | This variable is used to setup the severity of any of the Statistical alarms. So when a Statistical Counter exceeds its specified… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.8 | cds3LCV15MinThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be decl… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.9 | cds3LCV24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to b… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.10 | cds3LES15MinThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a 15 minute window causes which when exceeded in a 15 mi… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.11 | cds3LES24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to b… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.12 | cds3PCV15MinThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be decl… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.13 | cds3PCV24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to b… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.14 | cds3PES15MinThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be dec… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.15 | cds3PES24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to b… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.16 | cds3PSES15MinThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be decl… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.17 | cds3PSES24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to b… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.18 | cds3SEFS15MinThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be dec… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.19 | cds3SEFS24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to b… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.20 | cds3UAS15MinThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be dec… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.21 | cds3UAS24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to b… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.22 | cds3CCV15MinThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be dec… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.23 | cds3CCV24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.24 | cds3CES15MinThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be dec… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.25 | cds3CES24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to … |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.26 | cds3CSES15MinThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be dec… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.27 | cds3CSES24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to b… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.28 | cds3LSES15MinThreshold | 0 | 0 | Used to set the 15 minute threshold for LSES(Line Severely Errored Seconds). The value set in this object determines the value wh… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.29 | cds3LSES24HrThreshold | 0 | 0 | The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to b… |
1.3.6.1.4.1.9.9.132.1.2.1.1.1.30 | cds3LineStatisticalAlarmState | 0 | 0 | This is a bitmap of the DS3 Line Statistical alarms. It is represented as a sum where value 2^(N-1) is added to the sum if thresh… |