Reference record for OID 1.3.6.1.4.1.9.9.217.1.1.7



parent
1.3.6.1.4.1.9.9.217.1.1 (cc6kxbarConfiguration)
node code
7
node name
cc6kxbarDcefOnlyModeAllowed
dot oid
1.3.6.1.4.1.9.9.217.1.1.7
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoCat6kCrossbarMIB(217) ciscoCat6kXbarMIBObjects(1) cc6kxbarConfiguration(1) cc6kxbarDcefOnlyModeAllowed(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoCat6kCrossbarMIB(217) ciscoCat6kXbarMIBObjects(1) cc6kxbarConfiguration(1) cc6kxbarDcefOnlyModeAllowed(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoCat6kCrossbarMIB(217) ciscoCat6kXbarMIBObjects(1) cc6kxbarConfiguration(1) cc6kxbarDcefOnlyModeAllowed(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoCat6kCrossbarMIB(217) ciscoCat6kXbarMIBObjects(1) cc6kxbarConfiguration(1) cc6kxbarDcefOnlyModeAllowed(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoCat6kCrossbarMIB(217) ciscoCat6kXbarMIBObjects(1) cc6kxbarConfiguration(1) cc6kxbarDcefOnlyModeAllowed(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoCat6kCrossbarMIB(217) ciscoCat6kXbarMIBObjects(1) cc6kxbarConfiguration(1) cc6kxbarDcefOnlyModeAllowed(7)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoCat6kCrossbarMIB/ciscoCat6kXbarMIBObjects/cc6kxbarConfiguration/cc6kxbarDcefOnlyModeAllowed
  • /iso/identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoCat6kCrossbarMIB/ciscoCat6kXbarMIBObjects/cc6kxbarConfiguration/cc6kxbarDcefOnlyModeAllowed
  • /iso/org/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoCat6kCrossbarMIB/ciscoCat6kXbarMIBObjects/cc6kxbarConfiguration/cc6kxbarDcefOnlyModeAllowed
  • /iso/org/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoCat6kCrossbarMIB/ciscoCat6kXbarMIBObjects/cc6kxbarConfiguration/cc6kxbarDcefOnlyModeAllowed
  • /iso/iso-identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoCat6kCrossbarMIB/ciscoCat6kXbarMIBObjects/cc6kxbarConfiguration/cc6kxbarDcefOnlyModeAllowed
  • /iso/iso-identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoCat6kCrossbarMIB/ciscoCat6kXbarMIBObjects/cc6kxbarConfiguration/cc6kxbarDcefOnlyModeAllowed
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/9/9/217/1/1/7

    Description by circitor

    Indicates whether the dcef mode is enabled on the standby
    supervisor or not.
    'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true'
    makes the cc6kxbarModuleModeSwitchingMode of
    all the active modules to 'dcefmode'.
    With the active fabric module present in the system,
    with the switch being in stateful switchover mode,
    with all the cards that has no distributed Cisco
    Express forwarding switching support being
    powered down and on some platforms with standby
    supervisor ports being shutdown, changing
    cc6kxbarDcefOnlyModeAllowed to 'true' will make the
    standby supervisor module reloaded and booted up
    as distributed forwarding module.
    'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false'
    makes the cc6kxbarModuleModeSwitchingMode of the
    standby supervisor module to the default value.
    Changing cc6kxbarDcefOnlyModeAllowed to 'false'
    will make the standby supervisor reloaded and booted
    up with the default cc6kxbarModuleModeSwitchingMode.

    Parsed from file CISCO-CAT6K-CROSSBAR-MIB.mib
    Module: CISCO-CAT6K-CROSSBAR-MIB

    Description by cisco_v1

    Indicates whether the dcef mode is enabled on the standby
    supervisor or not.
    'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true'
    makes the cc6kxbarModuleModeSwitchingMode of
    all the active modules to 'dcefmode'.
    With the active fabric module present in the system,
    with the switch being in stateful switchover mode,
    with all the cards that has no distributed Cisco
    Express forwarding switching support being
    powered down and on some platforms with standby
    supervisor ports being shutdown, changing
    cc6kxbarDcefOnlyModeAllowed to 'true' will make the
    standby supervisor module reloaded and booted up
    as distributed forwarding module.
    'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false'
    makes the cc6kxbarModuleModeSwitchingMode of the
    standby supervisor module to the default value.
    Changing cc6kxbarDcefOnlyModeAllowed to 'false'
    will make the standby supervisor reloaded and booted
    up with the default cc6kxbarModuleModeSwitchingMode.

    Description by mibdepot

    Indicates whether the dcef mode is enabled on the standby
    supervisor or not.
    'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true'
    makes the cc6kxbarModuleModeSwitchingMode of
    all the active modules to 'dcefmode'.
    With the active fabric module present in the system,
    with the switch being in stateful switchover mode,
    with all the cards that has no distributed Cisco
    Express forwarding switching support being
    powered down and on some platforms with standby
    supervisor ports being shutdown, changing
    cc6kxbarDcefOnlyModeAllowed to 'true' will make the
    standby supervisor module reloaded and booted up
    as distributed forwarding module.
    'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false'
    makes the cc6kxbarModuleModeSwitchingMode of the
    standby supervisor module to the default value.
    Changing cc6kxbarDcefOnlyModeAllowed to 'false'
    will make the standby supervisor reloaded and booted
    up with the default cc6kxbarModuleModeSwitchingMode.

    Parsed from file CISCO-CAT6K-CROSSBAR-MIB.my.txt
    Company: None
    Module: CISCO-CAT6K-CROSSBAR-MIB

    Description by cisco

    Indicates whether the dcef mode is enabled on the standby
    supervisor or not.
    'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true'
    makes the cc6kxbarModuleModeSwitchingMode of
    all the active modules to 'dcefmode'.
    With the active fabric module present in the system,
    with the switch being in stateful switchover mode,
    with all the cards that has no distributed Cisco
    Express forwarding switching support being
    powered down and on some platforms with standby
    supervisor ports being shutdown, changing
    cc6kxbarDcefOnlyModeAllowed to 'true' will make the
    standby supervisor module reloaded and booted up
    as distributed forwarding module.
    'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false'
    makes the cc6kxbarModuleModeSwitchingMode of the
    standby supervisor module to the default value.
    Changing cc6kxbarDcefOnlyModeAllowed to 'false'
    will make the standby supervisor reloaded and booted
    up with the default cc6kxbarModuleModeSwitchingMode.

    Information by circitor

    cc6kxbarDcefOnlyModeAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the dcef mode is enabled on the standby supervisor or not. 'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the active modules to 'dcefmode'. With the active fabric module present in the system, with the switch being in stateful switchover mode, with all the cards that has no distributed Cisco Express forwarding switching support being powered down and on some platforms with standby supervisor ports being shutdown, changing cc6kxbarDcefOnlyModeAllowed to 'true' will make the standby supervisor module reloaded and booted up as distributed forwarding module. 'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false' makes the cc6kxbarModuleModeSwitchingMode of the standby supervisor module to the default value. Changing cc6kxbarDcefOnlyModeAllowed to 'false' will make the standby supervisor reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode." ::= { cc6kxbarConfiguration 7 }

    Information by cisco_v1

    cc6kxbarDcefOnlyModeAllowed OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS mandatory DESCRIPTION "Indicates whether the dcef mode is enabled on the standby supervisor or not. 'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the active modules to 'dcefmode'. With the active fabric module present in the system, with the switch being in stateful switchover mode, with all the cards that has no distributed Cisco Express forwarding switching support being powered down and on some platforms with standby supervisor ports being shutdown, changing cc6kxbarDcefOnlyModeAllowed to 'true' will make the standby supervisor module reloaded and booted up as distributed forwarding module. 'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false' makes the cc6kxbarModuleModeSwitchingMode of the standby supervisor module to the default value. Changing cc6kxbarDcefOnlyModeAllowed to 'false' will make the standby supervisor reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode." ::= { cc6kxbarConfiguration 7 }

    Information by oid_info

    Vendor: Cisco
    Module: CISCO-CAT6K-CROSSBAR-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    cc6kxbarDcefOnlyModeAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the dcef mode is enabled on the standby supervisor or not. 'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the active modules to 'dcefmode'. With the active fabric module present in the system, with the switch being in stateful switchover mode, with all the cards that has no distributed Cisco Express forwarding switching support being powered down and on some platforms with standby supervisor ports being shutdown, changing cc6kxbarDcefOnlyModeAllowed to 'true' will make the standby supervisor module reloaded and booted up as distributed forwarding module. 'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false' makes the cc6kxbarModuleModeSwitchingMode of the standby supervisor module to the default value. Changing cc6kxbarDcefOnlyModeAllowed to 'false' will make the standby supervisor reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode." ::= { cc6kxbarConfiguration 7 }

    Information by cisco

    cc6kxbarDcefOnlyModeAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the dcef mode is enabled on the standby supervisor or not. 'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the active modules to 'dcefmode'. With the active fabric module present in the system, with the switch being in stateful switchover mode, with all the cards that has no distributed Cisco Express forwarding switching support being powered down and on some platforms with standby supervisor ports being shutdown, changing cc6kxbarDcefOnlyModeAllowed to 'true' will make the standby supervisor module reloaded and booted up as distributed forwarding module. 'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false' makes the cc6kxbarModuleModeSwitchingMode of the standby supervisor module to the default value. Changing cc6kxbarDcefOnlyModeAllowed to 'false' will make the standby supervisor reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode." ::= { cc6kxbarConfiguration 7 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.9)

    Greg Satz

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.9)

    Cisco Systems, Inc.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.9.9.217.1.1.7.0 cc6kxbarDcefOnlyModeAllowed 0 0 None

    Brothers (8)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.9.9.217.1.1.1 cc6kxbarFallbackMode 1 1 cc6kxbarFallbackMode controls system fallback to bus-mode
    after loss of switching fabric module.
    'true' - When the last fabric c…
    1.3.6.1.4.1.9.9.217.1.1.2 cc6kxbarBusOnlyModeAllowed 1 1 Indicates whether bus mode is administratively enabled on
    the device or not.
    1.3.6.1.4.1.9.9.217.1.1.3 cc6kxbarTruncatedModeAllowed 1 1 Indicates whether truncated mode is
    administratively enabled on the device or not.
    1.3.6.1.4.1.9.9.217.1.1.4 cc6kxbarMinFabricPresent 1 1 This object indicates the minimum number
    of switching fabric capable modules to be present in the
    system, for any switching fabri…
    1.3.6.1.4.1.9.9.217.1.1.5 cc6kxbarLcdBannerTable 1 4 cc6kxbarLcdBannerTable configures the Lcd banner of the
    fabric module.
    1.3.6.1.4.1.9.9.217.1.1.6 cc6kxbarTruncatedModeOper 1 1 Indicates if the truncated mode is
    operationally enabled on the device or not.
    'true' - With the fabric module present in the sys…
    1.3.6.1.4.1.9.9.217.1.1.8 cc6kxbarForceBusMode 1 1 Indicates whether some affected modules are forced to be in
    'busmode' or not.
    'true' - Setting cc6kxbarForceBusMode to 'true' mak…
    1.3.6.1.4.1.9.9.217.1.1.9 cc6kxbarBusOnlyModeOper 1 1 Indicates if the bus mode is operationally enabled on the
    device or not.

    'true' - Modules are allowed to run in 'busmode'.
    'false'…