Reference record for OID 1.3.6.1.4.1.9.9.302.1.1.1.1.25



parent
1.3.6.1.4.1.9.9.302.1.1.1.1 (dmEntry)
node code
25
node name
dmFcIdPersistency
dot oid
1.3.6.1.4.1.9.9.302.1.1.1.1.25
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoDmMIB(302) ciscoDmMIBObjects(1) dmConfiguration(1) dmTable(1) dmEntry(1) dmFcIdPersistency(25)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoDmMIB(302) ciscoDmMIBObjects(1) dmConfiguration(1) dmTable(1) dmEntry(1) dmFcIdPersistency(25)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoDmMIB(302) ciscoDmMIBObjects(1) dmConfiguration(1) dmTable(1) dmEntry(1) dmFcIdPersistency(25)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoDmMIB(302) ciscoDmMIBObjects(1) dmConfiguration(1) dmTable(1) dmEntry(1) dmFcIdPersistency(25)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoDmMIB(302) ciscoDmMIBObjects(1) dmConfiguration(1) dmTable(1) dmEntry(1) dmFcIdPersistency(25)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoDmMIB(302) ciscoDmMIBObjects(1) dmConfiguration(1) dmTable(1) dmEntry(1) dmFcIdPersistency(25)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoDmMIB/ciscoDmMIBObjects/dmConfiguration/dmTable/dmEntry/dmFcIdPersistency
  • /iso/identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoDmMIB/ciscoDmMIBObjects/dmConfiguration/dmTable/dmEntry/dmFcIdPersistency
  • /iso/org/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoDmMIB/ciscoDmMIBObjects/dmConfiguration/dmTable/dmEntry/dmFcIdPersistency
  • /iso/org/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoDmMIB/ciscoDmMIBObjects/dmConfiguration/dmTable/dmEntry/dmFcIdPersistency
  • /iso/iso-identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoDmMIB/ciscoDmMIBObjects/dmConfiguration/dmTable/dmEntry/dmFcIdPersistency
  • /iso/iso-identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoDmMIB/ciscoDmMIBObjects/dmConfiguration/dmTable/dmEntry/dmFcIdPersistency
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/9/9/302/1/1/1/1/25

    Description by circitor

    Indicates if the FC IDs assigned on this VSAN are
    persistent or not.
    If this object is set to 'true', then all the FC ID
    assigned on this VSAN are made persistent on this VSAN.

    If this object is set to 'false', then all the entries on
    VSAN in dmFcIdPersistencyTable are deleted.

    An entry (or entries) is (or are) automatically created
    in the dmFcIdPersistencyTable with dmFcIfPersistencyWwn
    equal to either WWN of the FC device (if the local port
    is a F_port) for which the FC ID was assigned or WWN of
    local port (if the local port is a FL_port) and
    dmFcIdPersistencyType equal to 'dynamic'.

    The FC ID persistency can be enabled on this VSAN only
    if all the following conditions are satisfied:
    - the VSAN is active.
    - if dmConfigDomainIdType is equal is 'static' and
    dmConfigDomainId is not equal to zero on this VSAN.
    - if the dmConfigDomainId is equal to dmDomainId on
    this VSAN.

    Parsed from file CISCO-DM-MIB.mib
    Module: CISCO-DM-MIB

    Description by cisco_v1

    Indicates if the FC IDs assigned on this VSAN are
    persistent or not.
    If this object is set to 'true', then all the FC ID
    assigned on this VSAN are made persistent on this VSAN.

    If this object is set to 'false', then all the entries on
    VSAN in dmFcIdPersistencyTable are deleted.

    An entry (or entries) is (or are) automatically created
    in the dmFcIdPersistencyTable with dmFcIfPersistencyWwn
    equal to either WWN of the FC device (if the local port
    is a F_port) for which the FC ID was assigned or WWN of
    local port (if the local port is a FL_port) and
    dmFcIdPersistencyType equal to 'dynamic'.

    The FC ID persistency can be enabled on this VSAN only
    if all the following conditions are satisfied:
    - the VSAN is active.
    - if dmConfigDomainIdType is equal is 'static' and
    dmConfigDomainId is not equal to zero on this VSAN.
    - if the dmConfigDomainId is equal to dmDomainId on
    this VSAN.

    Description by mibdepot

    Indicates if the FC IDs assigned on this VSAN are
    persistent or not.
    If this object is set to 'true', then all the FC ID
    assigned on this VSAN are made persistent on this VSAN.

    If this object is set to 'false', then all the entries on
    VSAN in dmFcIdPersistencyTable are deleted.

    An entry (or entries) is (or are) automatically created
    in the dmFcIdPersistencyTable with dmFcIfPersistencyWwn
    equal to either WWN of the FC device (if the local port
    is a F_port) for which the FC ID was assigned or WWN of
    local port (if the local port is a FL_port) and
    dmFcIdPersistencyType equal to 'dynamic'.

    The FC ID persistency can be enabled on this VSAN only
    if all the following conditions are satisfied:
    - the VSAN is active.
    - if dmConfigDomainIdType is equal is 'static' and
    dmConfigDomainId is not equal to zero on this VSAN.
    - if the dmConfigDomainId is equal to dmDomainId on
    this VSAN.

    Parsed from file CISCO-DM-MIB.my.txt
    Company: None
    Module: CISCO-DM-MIB

    Description by cisco

    Indicates if the FC IDs assigned on this VSAN are
    persistent or not.
    If this object is set to 'true', then all the FC ID
    assigned on this VSAN are made persistent on this VSAN.

    If this object is set to 'false', then all the entries on
    VSAN in dmFcIdPersistencyTable are deleted.

    An entry (or entries) is (or are) automatically created
    in the dmFcIdPersistencyTable with dmFcIfPersistencyWwn
    equal to either WWN of the FC device (if the local port
    is a F_port) for which the FC ID was assigned or WWN of
    local port (if the local port is a FL_port) and
    dmFcIdPersistencyType equal to 'dynamic'.

    The FC ID persistency can be enabled on this VSAN only
    if all the following conditions are satisfied:
    - the VSAN is active.
    - if dmConfigDomainIdType is equal is 'static' and
    dmConfigDomainId is not equal to zero on this VSAN.
    - if the dmConfigDomainId is equal to dmDomainId on
    this VSAN.

    Information by circitor

    dmFcIdPersistency OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the FC IDs assigned on this VSAN are persistent or not. If this object is set to 'true', then all the FC ID assigned on this VSAN are made persistent on this VSAN. If this object is set to 'false', then all the entries on VSAN in dmFcIdPersistencyTable are deleted. An entry (or entries) is (or are) automatically created in the dmFcIdPersistencyTable with dmFcIfPersistencyWwn equal to either WWN of the FC device (if the local port is a F_port) for which the FC ID was assigned or WWN of local port (if the local port is a FL_port) and dmFcIdPersistencyType equal to 'dynamic'. The FC ID persistency can be enabled on this VSAN only if all the following conditions are satisfied: - the VSAN is active. - if dmConfigDomainIdType is equal is 'static' and dmConfigDomainId is not equal to zero on this VSAN. - if the dmConfigDomainId is equal to dmDomainId on this VSAN. " DEFVAL { false } ::= { dmEntry 25 }

    Information by cisco_v1

    dmFcIdPersistency OBJECT-TYPE SYNTAX TruthValue ACCESS read-write STATUS mandatory DESCRIPTION "Indicates if the FC IDs assigned on this VSAN are persistent or not. If this object is set to 'true', then all the FC ID assigned on this VSAN are made persistent on this VSAN. If this object is set to 'false', then all the entries on VSAN in dmFcIdPersistencyTable are deleted. An entry (or entries) is (or are) automatically created in the dmFcIdPersistencyTable with dmFcIfPersistencyWwn equal to either WWN of the FC device (if the local port is a F_port) for which the FC ID was assigned or WWN of local port (if the local port is a FL_port) and dmFcIdPersistencyType equal to 'dynamic'. The FC ID persistency can be enabled on this VSAN only if all the following conditions are satisfied: - the VSAN is active. - if dmConfigDomainIdType is equal is 'static' and dmConfigDomainId is not equal to zero on this VSAN. - if the dmConfigDomainId is equal to dmDomainId on this VSAN." DEFVAL { false } ::= { dmEntry 25 }

    Information by oid_info

    Vendor: Cisco
    Module: CISCO-DM-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    dmFcIdPersistency OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the FC IDs assigned on this VSAN are persistent or not. If this object is set to 'true', then all the FC ID assigned on this VSAN are made persistent on this VSAN. If this object is set to 'false', then all the entries on VSAN in dmFcIdPersistencyTable are deleted. An entry (or entries) is (or are) automatically created in the dmFcIdPersistencyTable with dmFcIfPersistencyWwn equal to either WWN of the FC device (if the local port is a F_port) for which the FC ID was assigned or WWN of local port (if the local port is a FL_port) and dmFcIdPersistencyType equal to 'dynamic'. The FC ID persistency can be enabled on this VSAN only if all the following conditions are satisfied: - the VSAN is active. - if dmConfigDomainIdType is equal is 'static' and dmConfigDomainId is not equal to zero on this VSAN. - if the dmConfigDomainId is equal to dmDomainId on this VSAN. " DEFVAL { false } ::= { dmEntry 25 }

    Information by cisco

    dmFcIdPersistency OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the FC IDs assigned on this VSAN are persistent or not. If this object is set to 'true', then all the FC ID assigned on this VSAN are made persistent on this VSAN. If this object is set to 'false', then all the entries on VSAN in dmFcIdPersistencyTable are deleted. An entry (or entries) is (or are) automatically created in the dmFcIdPersistencyTable with dmFcIfPersistencyWwn equal to either WWN of the FC device (if the local port is a F_port) for which the FC ID was assigned or WWN of local port (if the local port is a FL_port) and dmFcIdPersistencyType equal to 'dynamic'. The FC ID persistency can be enabled on this VSAN only if all the following conditions are satisfied: - the VSAN is active. - if dmConfigDomainIdType is equal is 'static' and dmConfigDomainId is not equal to zero on this VSAN. - if the dmConfigDomainId is equal to dmDomainId on this VSAN. " DEFVAL { false } ::= { dmEntry 25 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.9)

    Greg Satz

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.9)

    Cisco Systems, Inc.

    Brothers (25)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.9.9.302.1.1.1.1.1 dmConfigDomainId 0 0 The configured Domain ID of the local switch on this
    VSAN or zero if no Domain ID has been configured.
    The meaning of this object…
    1.3.6.1.4.1.9.9.302.1.1.1.1.2 dmConfigDomainIdType 0 0 Type of configured Domain ID.
    1.3.6.1.4.1.9.9.302.1.1.1.1.3 dmEnable 0 0 Enables the Domain Manager on this VSAN.

    If enabled on an active VSAN, the switch will
    participate in principal switch selection.…
    1.3.6.1.4.1.9.9.302.1.1.1.1.4 dmAutoReconfigure 0 0 This object determines how the switch responds to
    certain error conditions.

    The condition that can cause these errors is
    merging …
    1.3.6.1.4.1.9.9.302.1.1.1.1.5 dmContiguousAllocation 0 0 Determines how the switch behaves when elected
    as the principal switch.
    If true, switch won't accept non-contiguous domain
    IDs in …
    1.3.6.1.4.1.9.9.302.1.1.1.1.6 dmPriority 0 0 Priority of the switch to be used in principal switch
    selection process.
    1.3.6.1.4.1.9.9.302.1.1.1.1.7 dmRestart 0 0 This object tells the Domain Manager to rebuild the
    Domain ID tree all over again.

    If this object is set to 'disruptive', then a…
    1.3.6.1.4.1.9.9.302.1.1.1.1.8 dmFabricName 0 0 The WWN that is used for fabric logins on this VSAN.
    This object is used only if the value of dmEnable is
    false. If the value of …
    1.3.6.1.4.1.9.9.302.1.1.1.1.9 dmPrincipalSwitchWwn 0 0 The WWN of the Principal Switch on this VSAN, or
    zero-length string if the identity of the principal
    switch is unknown.
    1.3.6.1.4.1.9.9.302.1.1.1.1.10 dmLocalSwitchWwn 0 0 The WWN of the local Switch on this VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.11 dmAssignedAreaIdList 0 0 The list of Area IDs which have been assigned in this
    VSAN, formatted as an array of octets in ascending order.
    There could zero …
    1.3.6.1.4.1.9.9.302.1.1.1.1.12 dmFcIdsGranted 0 0 The total number of FC IDs that are granted (for local
    use) by the Domain Manager on the local switch since the
    switch has been i…
    1.3.6.1.4.1.9.9.302.1.1.1.1.13 dmFcIdsRecovered 0 0 The total number of FC IDs that are recovered by the
    Domain Manager on the local switch since the switch has
    been initialized. A …
    1.3.6.1.4.1.9.9.302.1.1.1.1.14 dmFreeFcIds 0 0 The number of FC IDs that are unassigned on this VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.15 dmAssignedFcIds 0 0 The number of FC IDs that are assigned on this VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.16 dmReservedFcIds 0 0 The number of FC IDs that are reserved on this VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.17 dmRunningPriority 0 0 The running priority of the local switch on this VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.18 dmPrincSwRunningPriority 0 0 The running priority of the principal switch on this
    VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.19 dmState 0 0 The state of the Domain Manager on the local switch on
    this VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.20 dmPrincipalSwitchSelections 0 0 The number of principal switch selections on this VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.21 dmBuildFabrics 0 0 The number of 'BuildFabrics' (BFs) that have occurred
    on this VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.22 dmFabricReconfigures 0 0 The number of 'ReconfigureFabrics' (RCFs) that have
    occurred on this VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.23 dmDomainId 0 0 The Domain ID of the local switch on this VSAN or zero
    if no Domain ID has been assigned.
    1.3.6.1.4.1.9.9.302.1.1.1.1.24 dmLocalPrincipalSwitchSelctns 0 0 The number of times the local switch became
    the principal switch on this VSAN.
    1.3.6.1.4.1.9.9.302.1.1.1.1.26 dmFcIdPurge 0 0 This object tells the Domain Manager to purge the FC IDs
    on this VSAN in the FC ID persistency database.

    If the value of this ob…