Reference record for OID 1.3.6.1.4.1.9.9.375.1.1.2.1.16



parent
1.3.6.1.4.1.9.9.375.1.1.2.1 (cficonVsanEntry)
node code
16
node name
cficonVsanClearAllegience
dot oid
1.3.6.1.4.1.9.9.375.1.1.2.1.16
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoFiconMIB(375) ciscoFiconMIBObjects(1) ciscoFiconConfig(1) cficonVsanTable(2) cficonVsanEntry(1) cficonVsanClearAllegience(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoFiconMIB(375) ciscoFiconMIBObjects(1) ciscoFiconConfig(1) cficonVsanTable(2) cficonVsanEntry(1) cficonVsanClearAllegience(16)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoFiconMIB(375) ciscoFiconMIBObjects(1) ciscoFiconConfig(1) cficonVsanTable(2) cficonVsanEntry(1) cficonVsanClearAllegience(16)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoFiconMIB(375) ciscoFiconMIBObjects(1) ciscoFiconConfig(1) cficonVsanTable(2) cficonVsanEntry(1) cficonVsanClearAllegience(16)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoFiconMIB(375) ciscoFiconMIBObjects(1) ciscoFiconConfig(1) cficonVsanTable(2) cficonVsanEntry(1) cficonVsanClearAllegience(16)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoFiconMIB(375) ciscoFiconMIBObjects(1) ciscoFiconConfig(1) cficonVsanTable(2) cficonVsanEntry(1) cficonVsanClearAllegience(16)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoFiconMIB/ciscoFiconMIBObjects/ciscoFiconConfig/cficonVsanTable/cficonVsanEntry/cficonVsanClearAllegience
  • /iso/identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoFiconMIB/ciscoFiconMIBObjects/ciscoFiconConfig/cficonVsanTable/cficonVsanEntry/cficonVsanClearAllegience
  • /iso/org/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoFiconMIB/ciscoFiconMIBObjects/ciscoFiconConfig/cficonVsanTable/cficonVsanEntry/cficonVsanClearAllegience
  • /iso/org/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoFiconMIB/ciscoFiconMIBObjects/ciscoFiconConfig/cficonVsanTable/cficonVsanEntry/cficonVsanClearAllegience
  • /iso/iso-identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoFiconMIB/ciscoFiconMIBObjects/ciscoFiconConfig/cficonVsanTable/cficonVsanEntry/cficonVsanClearAllegience
  • /iso/iso-identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoFiconMIB/ciscoFiconMIBObjects/ciscoFiconConfig/cficonVsanTable/cficonVsanEntry/cficonVsanClearAllegience
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/9/9/375/1/1/2/1/16

    Description by circitor

    The object used to clear a CUP allegiance.

    If this object is set with value, 'clear(1)'
    the CUP goes in a 'non-allegiance' or
    'unlocked' mode as described in the description
    of cficonVsanDeviceAllegience object above.

    Parsed from file CISCO-FICON-MIB.mib
    Module: CISCO-FICON-MIB

    Description by cisco_v1

    The object used to clear a CUP allegiance.

    If this object is set with value, 'clear(1)'
    the CUP goes in a 'non-allegiance' or
    'unlocked' mode as described in the description
    of cficonVsanDeviceAllegience object above.

    Description by mibdepot

    The object used to clear a CUP allegiance.

    If this object is set with value, 'clear(1)'
    the CUP goes in a 'non-allegiance' or
    'unlocked' mode as described in the description
    of cficonVsanDeviceAllegience object above.

    Parsed from file CISCO-FICON-MIB.my.txt
    Company: None
    Module: CISCO-FICON-MIB

    Description by cisco

    The object used to clear a CUP allegiance.

    If this object is set with value, 'clear(1)'
    the CUP goes in a 'non-allegiance' or
    'unlocked' mode as described in the description
    of cficonVsanDeviceAllegience object above.

    Information by circitor

    cficonVsanClearAllegience OBJECT-TYPE SYNTAX INTEGER { clear(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "The object used to clear a CUP allegiance. If this object is set with value, 'clear(1)' the CUP goes in a 'non-allegiance' or 'unlocked' mode as described in the description of cficonVsanDeviceAllegience object above." ::= { cficonVsanEntry 16 }

    Information by cisco_v1

    cficonVsanClearAllegience OBJECT-TYPE SYNTAX INTEGER { clear(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The object used to clear a CUP allegiance. If this object is set with value, 'clear(1)' the CUP goes in a 'non-allegiance' or 'unlocked' mode as described in the description of cficonVsanDeviceAllegience object above." ::= { cficonVsanEntry 16 }

    Information by oid_info

    Vendor: Cisco
    Module: CISCO-FICON-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    cficonVsanClearAllegience OBJECT-TYPE SYNTAX INTEGER { clear(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "The object used to clear a CUP allegiance. If this object is set with value, 'clear(1)' the CUP goes in a 'non-allegiance' or 'unlocked' mode as described in the description of cficonVsanDeviceAllegience object above." ::= { cficonVsanEntry 16 }

    Information by cisco

    cficonVsanClearAllegience OBJECT-TYPE SYNTAX INTEGER { clear(1) } MAX-ACCESS read-create STATUS current DESCRIPTION "The object used to clear a CUP allegiance. If this object is set with value, 'clear(1)' the CUP goes in a 'non-allegiance' or 'unlocked' mode as described in the description of cficonVsanDeviceAllegience object above." ::= { cficonVsanEntry 16 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.9)

    Greg Satz

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.9)

    Cisco Systems, Inc.

    Brothers (18)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.9.9.375.1.1.2.1.1 cficonVsanHostControl 0 0 The object indicates whether the host is allowed to
    alter FICON Director connectivity parameters.
    If 'true' the host is allowed t…
    1.3.6.1.4.1.9.9.375.1.1.2.1.2 cficonVsanHostControlSwOffline 0 0 The object specifying whether the host can put the VSAN
    offline.
    If 'true' it allows the host to put the VSAN offline,
    else it can…
    1.3.6.1.4.1.9.9.375.1.1.2.1.3 cficonVsanHostControlClkAlrtMode 0 0 The object indicates whether director clock alert mode
    is enabled or disabled.
    If 'true', the mode is enabled, else it is disable…
    1.3.6.1.4.1.9.9.375.1.1.2.1.4 cficonVsanSnmpControl 0 0 The object indicates whether network management system
    is allowed to alter FICON director connectivity
    parameters. If 'true', the…
    1.3.6.1.4.1.9.9.375.1.1.2.1.5 cficonVsanAutoSavePortAddrCfg 0 0 The object indicating whether the configuration will be
    saved in the configuration file for this VSAN.

    When an operator modifies …
    1.3.6.1.4.1.9.9.375.1.1.2.1.6 cficonVsanEnableCup 0 0 The object indicating Control Unit Port (CUP) is enabled.
    If 'true', CUP is enabled, else it is disabled.
    1.3.6.1.4.1.9.9.375.1.1.2.1.7 cficonVsanCodePage 0 0 The EBCDIC Code page used for the exchange of
    information with the host in this VSAN.
    1.3.6.1.4.1.9.9.375.1.1.2.1.8 cficonVsanCharSet 0 0 The Character Set used for the exchange of
    of information with the host in this VSAN.
    1.3.6.1.4.1.9.9.375.1.1.2.1.9 cficonVsanKeyCounter 0 0 A counter that is incremented every time there
    is a configuration change.

    This counter is used by the Host to keep track
    of the nu…
    1.3.6.1.4.1.9.9.375.1.1.2.1.10 cficonVsanUserAlertMode 0 0 The object indicating whether director user alert
    mode is enabled or disabled.
    If 'true', the mode is enabled. else it is
    disabled.
    1.3.6.1.4.1.9.9.375.1.1.2.1.11 cficonVsanDeviceAllegience 0 0 The object indicating whether CUP is in a allegiance
    state. If it is in allegiance state with a channel,
    it cannot accept any com…
    1.3.6.1.4.1.9.9.375.1.1.2.1.12 cficonVsanTime 0 0 The system time in the VSAN. This could be set
    either by the host or be the default global time
    in the FICON Director. The defaul…
    1.3.6.1.4.1.9.9.375.1.1.2.1.13 cficonVsanHostOrDefaultTime 0 0 The object indicating whether VSAN time is set by
    the host or the time is global time within a FICON
    Director. If 'true', the tim…
    1.3.6.1.4.1.9.9.375.1.1.2.1.14 cficonVsanCupName 0 0 The name of CUP.
    1.3.6.1.4.1.9.9.375.1.1.2.1.15 cficonSetHostTimeControl 0 0 The object indicating whether VSAN time can be
    set by the host.

    If 'true', the host can set the time, else it
    can not.
    1.3.6.1.4.1.9.9.375.1.1.2.1.17 cficonVsanEntryStatus 0 0 The status of this table entry.
    1.3.6.1.4.1.9.9.375.1.1.2.1.18 cficonVsanFiconState 0 0 The object used to control the state of
    the ports belonging to a vsan in the context
    of the FICON functionality.

    If this object is…
    1.3.6.1.4.1.9.9.375.1.1.2.1.19 cficonVsanSerialNum 0 0 The serial number of the FICON director.