The string describing the reason the the last 'apply'
command failed. This string needs to be polled only
in the case when the value of the cficonCfgFileCmdStatus
is 'failed'.
Parsed from file CISCO-FICON-MIB.mib
Module: CISCO-FICON-MIB
The string describing the reason the the last 'apply'
command failed. This string needs to be polled only
in the case when the value of the cficonCfgFileCmdStatus
is 'failed'.
The string describing the reason the the last 'apply'
command failed. This string needs to be polled only
in the case when the value of the cficonCfgFileCmdStatus
is 'failed'.
Parsed from file CISCO-FICON-MIB.my.txt
Company: None
Module: CISCO-FICON-MIB
The string describing the reason the the last 'apply'
command failed. This string needs to be polled only
in the case when the value of the cficonCfgFileCmdStatus
is 'failed'.
cficonCfgFileCmdErrorString OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The string describing the reason the the last 'apply' command failed. This string needs to be polled only in the case when the value of the cficonCfgFileCmdStatus is 'failed'. " ::= { cficonCfgFileEntry 8 }
cficonCfgFileCmdErrorString OBJECT-TYPE SYNTAX SnmpAdminString(SIZE(1..128)) ACCESS read-only STATUS mandatory DESCRIPTION "The string describing the reason the the last 'apply' command failed. This string needs to be polled only in the case when the value of the cficonCfgFileCmdStatus is 'failed'." ::= { cficonCfgFileEntry 8 }
Vendor: Cisco
Module: CISCO-FICON-MIB
[Automatically extracted from oidview.com]
cficonCfgFileCmdErrorString OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The string describing the reason the the last 'apply' command failed. This string needs to be polled only in the case when the value of the cficonCfgFileCmdStatus is 'failed'. " ::= { cficonCfgFileEntry 8 }
cficonCfgFileCmdErrorString OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The string describing the reason the the last 'apply' command failed. This string needs to be polled only in the case when the value of the cficonCfgFileCmdStatus is 'failed'. " ::= { cficonCfgFileEntry 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.375.1.1.5.1.1 | cficonCfgFilename | 0 | 0 | The name of the configuration file. |
1.3.6.1.4.1.9.9.375.1.1.5.1.2 | cficonCfgFileDescr | 0 | 0 | The description of the configuration file. |
1.3.6.1.4.1.9.9.375.1.1.5.1.3 | cficonCfgFileStatus | 0 | 0 | The status of filename containing these ports. Network Management station must check this object before it can read the contents … |
1.3.6.1.4.1.9.9.375.1.1.5.1.4 | cficonCfgFileLastUpdated | 0 | 0 | The time this file was last updated. The format is as follows - Wed Nov 5 18:53:52.172485 2003 |
1.3.6.1.4.1.9.9.375.1.1.5.1.5 | cficonCfgFileCmd | 0 | 0 | The object to apply this configuration file to the VSAN identified by the vsanIndex. When reading this object, a noOp(2) is retur… |
1.3.6.1.4.1.9.9.375.1.1.5.1.6 | cficonCfgFileRowStatus | 0 | 0 | The rowStatus of this row. |
1.3.6.1.4.1.9.9.375.1.1.5.1.7 | cficonCfgFileCmdStatus | 0 | 0 | The object to describe the status of the last 'apply' command. success - The last apply command was successful. inProgress … |