The maximum number of packets that can be queued for
transmission. If the monitor cannot send a TCP packet
immediately, the packet will be queued for retransmit.
This object defines the maximum number of TCP packets
that may be queued for retransmit. Once the number of
TCP packets on the queue reaches the value specified by
this object, additional TCP packets will be
dropped.
Parsed from file CISCO-ITP-MONITOR-MIB.mib
Module: CISCO-ITP-MONITOR-MIB
The maximum number of packets that can be queued for
transmission. If the monitor cannot send a TCP packet
immediately, the packet will be queued for retransmit.
This object defines the maximum number of TCP packets
that may be queued for retransmit. Once the number of
TCP packets on the queue reaches the value specified by
this object, additional TCP packets will be
dropped.
The maximum number of packets that can be queued for
transmission. If the monitor cannot send a TCP packet
immediately, the packet will be queued for retransmit.
This object defines the maximum number of TCP packets
that may be queued for retransmit. Once the number of
TCP packets on the queue reaches the value specified by
this object, additional TCP packets will be
dropped.
Parsed from file CISCO-ITP-MONITOR-MIB.my.txt
Company: None
Module: CISCO-ITP-MONITOR-MIB
The maximum number of packets that can be queued for
transmission. If the monitor cannot send a TCP packet
immediately, the packet will be queued for retransmit.
This object defines the maximum number of TCP packets
that may be queued for retransmit. Once the number of
TCP packets on the queue reaches the value specified by
this object, additional TCP packets will be
dropped.
cItpmConnMaxQDepth OBJECT-TYPE SYNTAX Unsigned32 (10..100000) UNITS "packets" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of packets that can be queued for transmission. If the monitor cannot send a TCP packet immediately, the packet will be queued for retransmit. This object defines the maximum number of TCP packets that may be queued for retransmit. Once the number of TCP packets on the queue reaches the value specified by this object, additional TCP packets will be dropped." DEFVAL { 100 } ::= { cItpmConnTableEntry 3 }
cItpmConnMaxQDepth OBJECT-TYPE SYNTAX Gauge(10..100000) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of packets that can be queued for transmission. If the monitor cannot send a TCP packet immediately, the packet will be queued for retransmit. This object defines the maximum number of TCP packets that may be queued for retransmit. Once the number of TCP packets on the queue reaches the value specified by this object, additional TCP packets will be dropped." DEFVAL { 100 } ::= { cItpmConnTableEntry 3 }
Vendor: Cisco
Module: CISCO-ITP-MONITOR-MIB
[Automatically extracted from oidview.com]
cItpmConnMaxQDepth OBJECT-TYPE SYNTAX Unsigned32 (10..100000) UNITS "packets" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of packets that can be queued for transmission. If the monitor cannot send a TCP packet immediately, the packet will be queued for retransmit. This object defines the maximum number of TCP packets that may be queued for retransmit. Once the number of TCP packets on the queue reaches the value specified by this object, additional TCP packets will be dropped." DEFVAL { 100 } ::= { cItpmConnTableEntry 3 }
cItpmConnMaxQDepth OBJECT-TYPE SYNTAX Unsigned32 (10..100000) UNITS "packets" MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of packets that can be queued for transmission. If the monitor cannot send a TCP packet immediately, the packet will be queued for retransmit. This object defines the maximum number of TCP packets that may be queued for retransmit. Once the number of TCP packets on the queue reaches the value specified by this object, additional TCP packets will be dropped." DEFVAL { 100 } ::= { cItpmConnTableEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.379.1.1.1.1.1 | cItpmConnPortNumber | 0 | 0 | The port number used to establish TCP connection. |
1.3.6.1.4.1.9.9.379.1.1.1.1.2 | cItpmConnKeepAlive | 0 | 0 | Specifies the keepalive time value in milliseconds. Keepalive packets are sent between the monitor and the remote server as a mec… |
1.3.6.1.4.1.9.9.379.1.1.1.1.4 | cItpmConnCongOnset | 0 | 0 | Threshold used to mark onset of congestion. When the cItpmConnQueueDepth object reaches value specified by this object the connec… |
1.3.6.1.4.1.9.9.379.1.1.1.1.5 | cItpmConnCongAbate | 0 | 0 | Threshold used to mark end of congestion. When the cItpmConnQueueDepth object drops below the value specified by this object the … |
1.3.6.1.4.1.9.9.379.1.1.1.1.6 | cItpmConnRcvWindowSize | 0 | 0 | The size of TCP receive window. This object defines the number of outstanding (unacknowledged) bytes that the ITP monitor can re… |
1.3.6.1.4.1.9.9.379.1.1.1.1.7 | cItpmConnFastStart | 0 | 0 | Defines the fast-start option for establishing TCP connectivity as follows. 'true' - FastStart is enabled. 'false' - FastStart… |
1.3.6.1.4.1.9.9.379.1.1.1.1.8 | cItpmConnQueueDepth | 0 | 0 | The number of packets queued for transmission. The maximum value is specified by the cItpmConnMaxQDepth object. |
1.3.6.1.4.1.9.9.379.1.1.1.1.9 | cItpmConnMonitorState | 0 | 0 | The state of the connection as follows. 'active' - connection is transmitting SS7 link traffic to server. 'inactive' - connecti… |
1.3.6.1.4.1.9.9.379.1.1.1.1.10 | cItpmConnCongestion | 0 | 0 | Congestion indicator for connection as follows. 'true' - connection is congested. 'false' - connection not congested. Congesti… |
1.3.6.1.4.1.9.9.379.1.1.1.1.11 | cItpmConnCongCounts | 0 | 0 | The number of times the connection has entered congestion. |