This notification is generated when the switch had to shed
loads based on power supply fail condition. cswSwitchNumCurrent
indicates the switch number of the system that goes through
immediate load shedding.
Parsed from file CISCO-STACKWISE-MIB.mib
Module: CISCO-STACKWISE-MIB
This notification is generated when the switch had to shed
loads based on power supply fail condition. cswSwitchNumCurrent
indicates the switch number of the system that goes through
immediate load shedding.
Parsed from file CISCO-STACKWISE-MIB.my.txt
Company: None
Module: CISCO-STACKWISE-MIB
This notification is generated when the switch had to shed
loads based on power supply fail condition. cswSwitchNumCurrent
indicates the switch number of the system that goes through
immediate load shedding.
cswStackPowerILS NOTIFICATION-TYPE OBJECTS { cswSwitchNumCurrent } STATUS current DESCRIPTION "This notification is generated when the switch had to shed loads based on power supply fail condition. cswSwitchNumCurrent indicates the switch number of the system that goes through immediate load shedding." ::= { cswMIBNotifications 20 }
Vendor: Cisco
Module: CISCO-STACKWISE-MIB
[Automatically extracted from oidview.com]
cswStackPowerILS NOTIFICATION-TYPE OBJECTS { cswSwitchNumCurrent } STATUS current DESCRIPTION "This notification is generated when the switch had to shed loads based on power supply fail condition. cswSwitchNumCurrent indicates the switch number of the system that goes through immediate load shedding." ::= { cswMIBNotifications 20 }
cswStackPowerILS NOTIFICATION-TYPE OBJECTS { cswSwitchNumCurrent } STATUS current DESCRIPTION "This notification is generated when the switch had to shed loads based on power supply fail condition. cswSwitchNumCurrent indicates the switch number of the system that goes through immediate load shedding." ::= { cswMIBNotifications 20 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.500.0.0.1 | cswStackPortChange | 0 | 0 | This notification is generated when the state of a stack port has changed. |
1.3.6.1.4.1.9.9.500.0.0.2 | cswStackNewMaster | 0 | 0 | This notification is generated when a new master has been elected. The notification will contain the cswSwitchNumCurrent object … |
1.3.6.1.4.1.9.9.500.0.0.3 | cswStackMismatch | 0 | 0 | This notification is generated when a new member attempt to join the stack but was denied due to a mismatch. The cswSwitchState … |
1.3.6.1.4.1.9.9.500.0.0.4 | cswStackRingRedundant | 0 | 0 | This notification is generated when the redundancy of the ring has changed. |
1.3.6.1.4.1.9.9.500.0.0.5 | cswStackNewMember | 0 | 0 | This notification is generated when a new member joins the stack. |
1.3.6.1.4.1.9.9.500.0.0.6 | cswStackMemberRemoved | 0 | 0 | This notification is generated when a member is removed from the stack. |
1.3.6.1.4.1.9.9.500.0.0.7 | cswStackPowerPortLinkStatusChanged | 0 | 0 | This notification is generated when the link status of a stack power port is changed from up to down or down to up. This notifica… |
1.3.6.1.4.1.9.9.500.0.0.8 | cswStackPowerPortOperStatusChanged | 0 | 0 | This notification is generated when the operational status of a stack power port is changed from enabled to disabled or from disa… |
1.3.6.1.4.1.9.9.500.0.0.9 | cswStackPowerVersionMismatch | 0 | 0 | This notification is generated when the major version of the stack power protocol is different from the other members of the powe… |
1.3.6.1.4.1.9.9.500.0.0.10 | cswStackPowerInvalidTopology | 0 | 0 | This notification is generated when an invalid stack power topology is discovered by a switch. cswSwitchNumCurrent indicates the … |
1.3.6.1.4.1.9.9.500.0.0.11 | cscwStackPowerBudgetWarrning | 0 | 0 | This notification is generated when the switch power budget is more than 1000W above its power supplies rated power output. cswSw… |
1.3.6.1.4.1.9.9.500.0.0.12 | cswStackPowerInvalidInputCurrent | 0 | 0 | This notification is generated when the input current in the stack power cable is over the limit of the threshold retrieved by th… |
1.3.6.1.4.1.9.9.500.0.0.13 | cswStackPowerInvalidOutputCurrent | 0 | 0 | This notification is generated when the output current in the stack power cable is over the limit of the threshold retrieved by t… |
1.3.6.1.4.1.9.9.500.0.0.14 | cswStackPowerUnderBudget | 0 | 0 | This notification is generated when the switch's budget is less than maximum possible switch power consumption. cswSwitchNumCurre… |
1.3.6.1.4.1.9.9.500.0.0.15 | cswStackPowerUnbalancedPowerSupplies | 0 | 0 | This notification is generated when the switch has no power supply but another switch in the same stack has more than one power s… |
1.3.6.1.4.1.9.9.500.0.0.16 | cswStackPowerInsufficientPower | 0 | 0 | This notification is generated when the switch's power stack does not have enough power to bring up all the switches in the power… |
1.3.6.1.4.1.9.9.500.0.0.17 | cswStackPowerPriorityConflict | 0 | 0 | This notification is generated when the switch's power priorities are conflicting with power priorities of another switch in the … |
1.3.6.1.4.1.9.9.500.0.0.18 | cswStackPowerUnderVoltage | 0 | 0 | This notification is generated when the switch had an under voltage condition on last boot up. cswSwitchNumCurrent indicates the … |
1.3.6.1.4.1.9.9.500.0.0.19 | cswStackPowerGLS | 0 | 0 | This notification is generated when the switch had to shed loads based on a sustained over load (SOC) condition. cswSwitchNumCurr… |
1.3.6.1.4.1.9.9.500.0.0.21 | cswStackPowerSRLS | 0 | 0 | This notification is generated when the switch had to shed loads based on loss of a system in ring topology. cswSwitchNumCurrent … |
1.3.6.1.4.1.9.9.500.0.0.22 | cswStackPowerSSLS | 0 | 0 | This notification is generated when the switch had to shed loads based on loss of a system in star topology. cswSwitchNumCurrent … |
1.3.6.1.4.1.9.9.500.0.0.23 | cswStackMemberToBeReloadedForUpgrade | 0 | 0 | This notification is generated when a member is to be reloaded for upgrade. |