This object specifies the High Availability policy
of a particular VDC when both the active supervisor and
standby supervisor are present on the device.
This object specifies the High Availability policy
of a particular VDC when both the active supervisor and
standby supervisor are present on the device.
ciscoVdcDualSupHaPolicy OBJECT-TYPE SYNTAX CiscoVdcHaPolicy ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the High Availability policy of a particular VDC when both the active supervisor and standby supervisor are present on the device." DEFVAL { switchOver } ::= { ciscoVdcExtEntry 2 }
ciscoVdcDualSupHaPolicy OBJECT-TYPE SYNTAX CiscoVdcHaPolicy MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the High Availability policy of a particular VDC when both the active supervisor and standby supervisor are present on the device." DEFVAL { switchOver } ::= { ciscoVdcExtEntry 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.9.9.774.1.3.1.1.1 | ciscoVdcSingleSupHaPolicy | 0 | 0 | This object specifies the High Availability policy of a particular VDC when there is only one supervisor on the device. |
1.3.6.1.4.1.9.9.774.1.3.1.1.3 | ciscoVdcBootOrder | 0 | 0 | This object specifies the boot order value for this particular VDC. The VDCs with the lowest boot order will boot first. |
1.3.6.1.4.1.9.9.774.1.3.1.1.4 | ciscoVdcTimeCreated | 0 | 0 | This object indicates the time at which a particular VDC was created. |
1.3.6.1.4.1.9.9.774.1.3.1.1.5 | ciscoVdcReloadCount | 0 | 0 | This object indicates the number of times a particular VDC has been reloaded. |
1.3.6.1.4.1.9.9.774.1.3.1.1.6 | ciscoVdcRestartCount | 0 | 0 | This object indicates the number of times a VDC identified by ciscoVdcId has been restarted. |
1.3.6.1.4.1.9.9.774.1.3.1.1.7 | ciscoVdcRestartTime | 0 | 0 | This object indicates the most recent restart time of the VDC instance. This object contains value 0x0000010100000000 when the cor… |
1.3.6.1.4.1.9.9.774.1.3.1.1.8 | ciscoVdcRestartReason | 0 | 0 | This object indicates the reason of the most recent restart of the VDC. |
1.3.6.1.4.1.9.9.774.1.3.1.1.9 | ciscoVdcType | 0 | 0 | This object specifies the type of the VDC. |
1.3.6.1.4.1.9.9.774.1.3.1.1.10 | ciscoVdcAdminStatus | 0 | 0 | This object indicates the administrative status of the VDC. active suspended When the suspended VDC is bening resumed, it will come… |
1.3.6.1.4.1.9.9.774.1.3.1.1.11 | ciscoVdcFromUnallocatedIntf | 0 | 0 | This object specifies the way that interfaces are allocated from the unallocated interface pool. When the value of this object is… |
1.3.6.1.4.1.9.9.774.1.3.1.1.12 | ciscoVdcFeatureSetList | 0 | 0 | None |
1.3.6.1.4.1.9.9.774.1.3.1.1.13 | ciscoVdcResourceTemplate | 0 | 0 | This object specifies the name of the resource template of the VDC. |
1.3.6.1.4.1.9.9.774.1.3.1.1.14 | ciscoVdcModuleCapList | 0 | 0 | None |
1.3.6.1.4.1.9.9.774.1.3.1.1.15 | ciscoVdcCpuPriority | 0 | 0 | This object specifies the CPU priority/share for a particular VDC. A value of -1 means this information is not available. |
1.3.6.1.4.1.9.9.774.1.3.1.1.16 | ciscoVdcCpuSharePercent | 0 | 0 | This object indicates the CPU share percentage for a particular VDC. |